PreprintCC BY 4.0Zenodo
Three Instrument Floors: null calibration of a composite EEG/HRV index on consumer hardware
- 1Coheron Laboratory
Abstract
A composite real-time index built from consumer EEG and heart-rate variability returns a number on any input, including input containing nothing. This paper measures what each factor of such an index returns on structureless input pushed through the identical processing chain, so the floor carries every artifact the real pipeline carries. Reports the measured floors, a corrected signal-to-noise estimate, the effect of channel clipping and dropout, within-recording window independence, and the limits of what a single recording can establish. All numbers reproduce from one raw capture and the shipped scripts.
Related
- Extraction of clinical information from faxed medical records using a small local large language model pipeline on consumer hardware
- Democratizing Clinical Tumor Whole Genome Sequencing: 18-hour End-to-end Analysis via Trillion-parameter Large Language Models Locally Deployed on Consumer-grade Hardware
- Cement-free composite brick from waste foundry sand and mixed post-consumer thermoplastic waste for sustainable construction
- Calibration electronics for the 30 and 40 GHz instrument (TFGI) of the QUIJOTE experiment
- A single-user feasibility study demonstrating real-time raycast-based stair and elevation-change detection on consumer smartphone LiDAR hardware
BibTeX
@misc{almasy2026three,
title = {{Three Instrument Floors: null calibration of a composite EEG/HRV index on consumer hardware}},
author = {Jason Almasy},
howpublished = {Zenodo},
year = {2026},
month = oct,
doi = {10.5281/zenodo.23629659},
url = {https://zenodo.org/records/23629659},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Three Instrument Floors: null calibration of a composite EEG/HRV index on consumer hardware
AU - Jason Almasy
PY - 2026
DA - 2026/10/24
PB - Zenodo
DO - 10.5281/zenodo.23629659
UR - https://zenodo.org/records/23629659
AB - A composite real-time index built from consumer EEG and heart-rate variability returns a number on any input, including input containing nothing. This paper measures what each factor of such an index returns on structureless input pushed through the identical processing chain, so the floor carries every artifact the real pipeline carries. Reports the measured floors, a corrected signal-to-noise estimate, the effect of channel clipping and dropout, within-recording window independence, and the limits of what a single recording can establish. All numbers reproduce from one raw capture and the shipped scripts.
ER -