An interpretable, formally verified point-of-care ultrasound risk equation for difficult videolaryngoscopy: development and internal validation

Abstract

BackgroundVideolaryngoscopy still requires adjuncts or hyperangulated rescue in a clinically important minority, and bedside screening discriminates modestly. Point-of-care ultrasound (POCUS) of the anterior airway is a promising alternative, but existing prediction models are opaque or assume a pre-specified functional form. We developed and internally validated a parsimonious, fully disclosed POCUS risk equation whose form is recovered from data and whose structural properties are machine-checked by formal proof -- to our knowledge the first formally verified clinical risk predictor -- following TRIPOD+AI 2024.

MethodsIn a prospective single-centre, single-operator cohort of 259 adults undergoing elective videolaryngoscopy (no-Easy airway 68/259, 26.3%), Sequentially Thresholded Least Squares with bootstrap stability selection (B = 300) screened a 71-term library of nine POCUS features and retained a seven-term logistic equation; a two-term bootstrap-stable model was pre-specified as robustness analysis. Internal validation used 5 x 10 repeated cross-validation plus temporal and device hold-outs, with pre-specified overfitting and optimism assessments. Five behavioural properties of the deployed equation were machine-checked in Lean 4.

ResultsTwo interactions met the |c|/{sigma}c > 2 stability criterion: skin-to-epiglottis x skin-to-hyoid-bone distance and tongue volume x sagittal tongue area. The seven-term equation reached a 5 x 10 cross-validated C-statistic of 0.966 (optimism-corrected 0.968) and held across temporal and device hold-outs (0.94-0.97). Calibration-in-the-large matched prevalence, with cross-validated slope 0.90 attenuating to 0.625 out-of-time; standard recalibration restored 0.92 without loss of discrimination. The pre-specified two-term robustness model reproduced this performance (C-statistic 0.964-0.968; events-per-parameter 34; shrinkage 0.99), confirming the result is not an artefact of the screening stage. Net benefit over a clinical baseline was positive across 10-50% thresholds. All five Lean 4 theorems compiled without sorry.

ConclusionsA sparse, formally verified POCUS equation predicts difficult videolaryngoscopy with high internally validated discrimination and quantified, modest overfitting. Because the equation was developed in a single-operator cohort and its inputs are operator-dependent, external validation requires prior harmonisation of the measurement protocol and operator credentialing.

Related

  1. Development and Internal Validation of a Preoperative Risk Stratification Model for Difficult Laparoscopic Cholecystectomy in Acute Cholecystitis
    Sinan Aslan, Şebnem Çimen
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Development and validation of an interpretable machine learning model for early prediction of mortality in ICU patients with chronic obstructive pulmonary disease and heart failure
    Jiayi Shen, Yucheng Liu, Yikun Chen
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Development and validation of an interpretable prediction model for high-grade vesicoureteral reflux in children with urinary tract infections
    Le-zhen Ye, Jian-xin Sun, Jing Chen +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Development and validation of an interpretable machine learning model for predicting in-hospital mortality among critically ill patients with liver cirrhosis
    Fengjie Guo, Shijie Zhong, Yang Tan +6
    Scientific ReportsPeer-reviewedCC BYFull text1 citedGeneral medicineDOAJ
  5. Ultrasound guidance versus near-infrared light versus the standard technique for first-attempt success of peripheral intravenous catheterisation in adults with difficult venous access in a medical imaging department (RÉUSSIR-VVP): protocol for a single-centre, three arms, randomised controlled trial
    Guillaume Davy, Florian Nassiri, Victor Dumas +3
    BMJ OpenPeer-reviewedCC BY-NC 4.0Full textGeneral medicineCrossref
BibTeX
@misc{oyarzunsilva2026interpretable,
  title = {{An interpretable, formally verified point-of-care ultrasound risk equation for difficult videolaryngoscopy: development and internal validation}},
  author = {R. A. Oyarzun-Silva and P. Hernandez-Hernandez and M. A. Fernandez-Vaquero and N. De Luis-Cabezon},
  howpublished = {medRxiv},
  year = {2026},
  month = aug,
  doi = {10.64898/2026.08.28.26361621},
  url = {https://www.medrxiv.org/content/10.64898/2026.08.28.26361621v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - An interpretable, formally verified point-of-care ultrasound risk equation for difficult videolaryngoscopy: development and internal validation
AU  - R. A. Oyarzun-Silva
AU  - P. Hernandez-Hernandez
AU  - M. A. Fernandez-Vaquero
AU  - N. De Luis-Cabezon
PY  - 2026
DA  - 2026/08/28
PB  - medRxiv
DO  - 10.64898/2026.08.28.26361621
UR  - https://www.medrxiv.org/content/10.64898/2026.08.28.26361621v1
AB  - BackgroundVideolaryngoscopy still requires adjuncts or hyperangulated rescue in a clinically important minority, and bedside screening discriminates modestly. Point-of-care ultrasound (POCUS) of the anterior airway is a promising alternative, but existing prediction models are opaque or assume a pre-specified functional form. We developed and internally validated a parsimonious, fully disclosed POCUS risk equation whose form is recovered from data and whose structural properties are machine-checked by formal proof -- to our knowledge the first formally verified clinical risk predictor -- following TRIPOD+AI 2024.  MethodsIn a prospective single-centre, single-operator cohort of 259 adults undergoing elective videolaryngoscopy (no-Easy airway 68/259, 26.3%), Sequentially Thresholded Least Squares with bootstrap stability selection (B = 300) screened a 71-term library of nine POCUS features and retained a seven-term logistic equation; a two-term bootstrap-stable model was pre-specified as robustness analysis. Internal validation used 5 x 10 repeated cross-validation plus temporal and device hold-outs, with pre-specified overfitting and optimism assessments. Five behavioural properties of the deployed equation were machine-checked in Lean 4.  ResultsTwo interactions met the |c|/{sigma}c > 2 stability criterion: skin-to-epiglottis x skin-to-hyoid-bone distance and tongue volume x sagittal tongue area. The seven-term equation reached a 5 x 10 cross-validated C-statistic of 0.966 (optimism-corrected 0.968) and held across temporal and device hold-outs (0.94-0.97). Calibration-in-the-large matched prevalence, with cross-validated slope 0.90 attenuating to 0.625 out-of-time; standard recalibration restored 0.92 without loss of discrimination. The pre-specified two-term robustness model reproduced this performance (C-statistic 0.964-0.968; events-per-parameter 34; shrinkage 0.99), confirming the result is not an artefact of the screening stage. Net benefit over a clinical baseline was positive across 10-50% thresholds. All five Lean 4 theorems compiled without sorry.  ConclusionsA sparse, formally verified POCUS equation predicts difficult videolaryngoscopy with high internally validated discrimination and quantified, modest overfitting. Because the equation was developed in a single-operator cohort and its inputs are operator-dependent, external validation requires prior harmonisation of the measurement protocol and operator credentialing.
ER  -