Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients

  1. 1Section of Cardiac Electrophysiology, Department of Medicine Emory University School of Medicine Atlanta Georgia USA
  2. 2Department of Epidemiology Emory University Rollins School of Public Health Atlanta Georgia USA

Abstract

Background: Consensus‐recommended follow‐up after cardiac implantable electronic device (CIED) implantation improves outcomes, yet whether it mediates cardiovascular disparities between device types remains unknown.

Methods: We prospectively studied 6806 patients undergoing CIED implantation across a multi‐hospital system (2019–2023; median follow‐up 3.5 years), categorized as implantable cardioverter defibrillator (ICD) (n = 2757) or permanent pacemaker (PPM) (n = 4049). Causal mediation analysis decomposed the effect of device type on major adverse cardiovascular events (MACE) and device extraction into direct and follow‐up mediated components, adjusting for demographics and comorbidities.

Results: ICD recipients had significantly lower consensus‐recommended follow‐up rates than PPM recipients (65.3% vs. 79.2%; adjusted OR 0.46, 95% CI 0.40–0.52, p < 0.001) and substantially higher MACE risk (HR 1.89, 95% CI 1.66–2.25, p < 0.001), of which 53.5% was mediated by follow‐up adherence. Device extraction rates were lower in ICD recipients (HR 0.30, 95% CI 0.24–0.38), with only 7.9% mediated by follow‐up adherence.

Conclusions: More than half of the excess cardiovascular risk in ICD recipients was statistically mediated by suboptimal follow‐up adherence—a potentially modifiable pathway. These findings identify follow‐up adherence as a potentially important pathway and support further prospective investigation of strategies to improve monitoring and clinical outcomes in high‐risk CIED populations.

Related

  1. Inappropriate ventricular fibrillation detection by extravascular implantable cardioverter-defibrillator.
    Banveet Kaur, Jaime McCoin, Anh Le +3
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  2. Radiofrequency ablation with a conventional solid tip catheter in contact with an implantable cardioverter-defibrillator coil causing inadvertent ventricular fibrillation.
    Michael R Manogue
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  3. Ventricular fibrillation treated by an implantable cardioverter-defibrillator in antimitochondrial M2 antibody-positive myocarditis.
    Kanto Saida, Atsushi Sudo, Takunori Aoyama +2
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  4. Transient defibrillation threshold elevation associated with air in the generator pocket after extravascular implantable cardioverter-defibrillator implantation.
    Junji Morita, Kenichiro Yamagata, Yuhei Kasai +1
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  5. Approach to epicardial access for ventricular tachycardia ablation in a patient with an extravascular implantable cardioverter-defibrillator.
    Aditya Somasundaram, Naima Maqsood, Sean Dikdan +1
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
BibTeX
@article{huang2026consensusrecommended,
  title = {{Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients}},
  author = {Jingwen Huang and Rahul Patel and Chang Liu and Michael S. Lloyd},
  journal = {Journal of Cardiovascular Electrophysiology},
  year = {2026},
  month = oct,
  doi = {10.1111/jce.70521},
  url = {https://doi.org/10.1111/jce.70521},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Consensus‐Recommended Follow‐Up Mediates Cardiovascular Outcomes Disparities Between Implantable Cardioverter Defibrillator and Pacemaker Recipients
AU  - Jingwen Huang
AU  - Rahul Patel
AU  - Chang Liu
AU  - Michael S. Lloyd
PY  - 2026
DA  - 2026/10/06
JO  - Journal of Cardiovascular Electrophysiology
DO  - 10.1111/jce.70521
UR  - https://doi.org/10.1111/jce.70521
AB  - Background: Consensus‐recommended follow‐up after cardiac implantable electronic device (CIED) implantation improves outcomes, yet whether it mediates cardiovascular disparities between device types remains unknown.  Methods: We prospectively studied 6806 patients undergoing CIED implantation across a multi‐hospital system (2019–2023; median follow‐up 3.5 years), categorized as implantable cardioverter defibrillator (ICD) (n = 2757) or permanent pacemaker (PPM) (n = 4049). Causal mediation analysis decomposed the effect of device type on major adverse cardiovascular events (MACE) and device extraction into direct and follow‐up mediated components, adjusting for demographics and comorbidities.  Results: ICD recipients had significantly lower consensus‐recommended follow‐up rates than PPM recipients (65.3% vs. 79.2%; adjusted OR 0.46, 95% CI 0.40–0.52, p < 0.001) and substantially higher MACE risk (HR 1.89, 95% CI 1.66–2.25, p < 0.001), of which 53.5% was mediated by follow‐up adherence. Device extraction rates were lower in ICD recipients (HR 0.30, 95% CI 0.24–0.38), with only 7.9% mediated by follow‐up adherence.  Conclusions: More than half of the excess cardiovascular risk in ICD recipients was statistically mediated by suboptimal follow‐up adherence—a potentially modifiable pathway. These findings identify follow‐up adherence as a potentially important pathway and support further prospective investigation of strategies to improve monitoring and clinical outcomes in high‐risk CIED populations.
SN  - 1045-3873
SN  - 1540-8167
ER  -