Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BYGenome medicine

Evidence-based recommendations for application of construct-based splicing data in clinical variant classification.

5 affiliations
  1. 1Population Health Program, QIMR Berghofer, Herston, QLD, 4006, Australia.
  2. 2Department of Pathology and Molecular Medicine, University of Otago, Christchurch, New Zealand.
  3. 3Splicing and Genetic Susceptibility to Cancer, Instituto de Biomedicina y Genética Molecular de Valladolid (IBGM), Consejo Superior de Investigaciones Científicas - Universidad de Valladolid (CSIC-UVa), Valladolid, 47003, Spain.
  4. 4Department of Medicine, University of Otago, Christchurch, New Zealand.
  5. 5Department of Pathology and Molecular Medicine, University of Otago, Christchurch, New Zealand. [email protected].

Abstract

Background

Minigene RT-PCR assays are widely used to assess variant impact on splicing, with increasing reports of massively parallel splicing assays (MPSAs) demonstrating potential to upscale diagnostic use of construct-based data. This study conducted a comprehensive evaluation of > 41,000 variants from construct-based splicing assays, to build evidence-based recommendations to support the consistent application of such assays in clinical variant interpretation.Methods

Seven MPSAs were reviewed for design limitations, and their discriminatory performance evaluated by assessing: assay score distribution; consistency of splice-impact thresholds with expectations based on SpliceAI predictions. A traditional minigene RT-PCR dataset comprising 673 variants from 14 studies was analysed to: assess potential for SpliceAI score to predict level of aberration; demonstrate performance of SpliceAI-10k calculator (SAI-10k-calc) to accurately predict variant-induced splicing events; calibrate evidence strength towards or against spliceogenicity based on SpliceAI score. Traditional minigene results were compared to patient-derived RNA results, and calibrated for evidence strength towards or against pathogenicity using assertions from ClinVar.Results

MPSA datasets lacked specific information on variant-induced transcripts and had design limitations preventing detection of some aberrant splice events. Assay scores generated by five of seven MPSAs were unable to differentiate aberrant from natural splicing events. Traditional minigene results showed high predictive agreement between predicted and observed variant-induced events: SpliceAI score of 0.285 showed 90% sensitivity and 90% specificity for separating no/low versus intermediate-to-complete aberration, and agreement was 87% for aberration type using SAI-10k-calc. Minigene and patient-derived RNA results showed 89% (81/91) complete or high concordance for predominant transcripts. Clinical calibration of minigene results showed that high (≥ 80%) or low (≤ 20%) expression of variant-induced loss of function (LOF) transcripts provide strong evidence towards or against pathogenicity, respectively. Evidence-based recommendations for design and critique of construct-based assays were built based on these and other findings.Conclusions

MPSA screens require review of design limitations and performance evaluation before considering their suitability for clinical variant interpretation. Well-designed multi-exon minigene assays can provide quantitative RNA results to supplement patient-derived RNA findings, and clinical calibration justifies their use in the diagnostic setting. Altogether, these findings support more consistent application of RNA evidence in clinical practice.

Related

  1. ClinGen Glaucoma Variant Curation Expert Panel Recommendations Enhance Classification of Myocilin Variants.
    Stuart W J Tompson, Patricia Graham, Johanna Hadler +12
    Human mutationPeer-reviewedCC BYFull textGenetics & genomicsEurope PMC
  2. Application of Bayesian-Derived Gene Interaction Network and Subnetwork for Classification of Idiopathic Parkinson Disease with Biomarkers
    R. Yang, Y. Yuan
    bioRxivPreprintAll rights reservedFull textBioinformatics & computational biologybioRxiv
  3. Does midterm reinforcement improve compliance with farm-specific cow-comfort recommendations? Evidence from a nested randomized controlled trial in Kenyan smallholder dairy farms.
    Emmanuel Muunda, Elizaphan James O Rao, David C Hall +3
    Veterinary and animal sciencePeer-reviewedCC BYFull textZoology & animal behaviourEurope PMCPMC
  4. The application of Chicago classification 4.0 in esophageal motility disorders of scleroderma: a case-control study in China
    Yinghui Yang, Siwei Xie, Minyi Xu +2
    Frontiers in ImmunologyPeer-reviewedCC BY 4.0Full textImmunologyCrossrefEurope PMC
  5. PhageLysClass: Evidence-aware classification of phage lytic proteins using protein language models
    D. Medina-Ortiz, A. Olivera-Nappa, M. E. Lienqueo +2
    bioRxivPreprintCC BYFull textBioinformatics & computational biologybioRxiv
BibTeX
@article{canson2026evidencebased,
  title = {{Evidence-based recommendations for application of construct-based splicing data in clinical variant classification.}},
  author = {Daffodil M Canson and George A R Wiggins and Eladio A Velasco-Sampedro and John F Pearson and Logan C Walker and Amanda B Spurdle},
  journal = {Genome medicine},
  year = {2026},
  month = aug,
  doi = {10.1186/s13073-026-01746-3},
  url = {https://europepmc.org/article/MED/43010041},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Evidence-based recommendations for application of construct-based splicing data in clinical variant classification.
AU  - Daffodil M Canson
AU  - George A R Wiggins
AU  - Eladio A Velasco-Sampedro
AU  - John F Pearson
AU  - Logan C Walker
AU  - Amanda B Spurdle
PY  - 2026
DA  - 2026/08/01
JO  - Genome medicine
DO  - 10.1186/s13073-026-01746-3
UR  - https://europepmc.org/article/MED/43010041
AB  - Background  Minigene RT-PCR assays are widely used to assess variant impact on splicing, with increasing reports of massively parallel splicing assays (MPSAs) demonstrating potential to upscale diagnostic use of construct-based data. This study conducted a comprehensive evaluation of > 41,000 variants from construct-based splicing assays, to build evidence-based recommendations to support the consistent application of such assays in clinical variant interpretation.Methods  Seven MPSAs were reviewed for design limitations, and their discriminatory performance evaluated by assessing: assay score distribution; consistency of splice-impact thresholds with expectations based on SpliceAI predictions. A traditional minigene RT-PCR dataset comprising 673 variants from 14 studies was analysed to: assess potential for SpliceAI score to predict level of aberration; demonstrate performance of SpliceAI-10k calculator (SAI-10k-calc) to accurately predict variant-induced splicing events; calibrate evidence strength towards or against spliceogenicity based on SpliceAI score. Traditional minigene results were compared to patient-derived RNA results, and calibrated for evidence strength towards or against pathogenicity using assertions from ClinVar.Results  MPSA datasets lacked specific information on variant-induced transcripts and had design limitations preventing detection of some aberrant splice events. Assay scores generated by five of seven MPSAs were unable to differentiate aberrant from natural splicing events. Traditional minigene results showed high predictive agreement between predicted and observed variant-induced events: SpliceAI score of 0.285 showed 90% sensitivity and 90% specificity for separating no/low versus intermediate-to-complete aberration, and agreement was 87% for aberration type using SAI-10k-calc. Minigene and patient-derived RNA results showed 89% (81/91) complete or high concordance for predominant transcripts. Clinical calibration of minigene results showed that high (≥ 80%) or low (≤ 20%) expression of variant-induced loss of function (LOF) transcripts provide strong evidence towards or against pathogenicity, respectively. Evidence-based recommendations for design and critique of construct-based assays were built based on these and other findings.Conclusions  MPSA screens require review of design limitations and performance evaluation before considering their suitability for clinical variant interpretation. Well-designed multi-exon minigene assays can provide quantitative RNA results to supplement patient-derived RNA findings, and clinical calibration justifies their use in the diagnostic setting. Altogether, these findings support more consistent application of RNA evidence in clinical practice.
SN  - 1756-994X
ER  -