Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BYScientific Reports

Influence of pressure sensor equipped handpiece and vitreous removal on posterior capsule movement during occlusion break in porcine eyes

  1. 1Zengyo Suzuki Eye Clinic Fujisawa

Abstract

Posterior capsule stability is a key determinant of safety in phacoemulsification; however, the influence of the vitreous on its dynamics remains unclear. This non-clinical study evaluated the stabilizing effect of the Active Sentry (AS) handpiece and the impact of vitreous absence using an ex vivo vitrectomized porcine eye model. Posterior capsule elevation following an occlusion break was quantified across four vitrectomized groups (AS or Ozil [OZ] handpieces), with or without eyelid speculum [ES] and compared with previously reported vitreous-intact data from the same series using an identical protocol. At 20 mmHg intraocular pressure, the posterior capsule elevation ratio was significantly lower with the AS than with the OZ handpiece, both without ES (3.8 ± 1.3% vs. 8.4 ± 3.9%) and with ES (10.1 ± 12.3% vs. 20.0 ± 14.4%) (both P = 0.0010). Vitrectomized eyes showed reduced elevation compared with vitreous-intact eyes in the ES model: 10.1 ± 12.3% vs. 18.0 ± 19.1% with the AS (P = 0.0215) and 20.0 ± 14.4% vs. 46.2 ± 20.2% with the OZ (P = 0.0031). In conclusion, the AS handpiece stabilized the posterior capsule independently of vitreous support. Vitrectomized eyes did not show increased posterior capsule instability, and exploratory, independently sampled comparisons suggested that vitreous absence may be associated with attenuated elevation during surge events; this observation should be interpreted as hypothesis-generating.

Related

  1. Endovascular Recanalization of Non-Acute Vertebrobasilar Occlusion in Progressive Posterior Circulation Ischemia: A Case Report
    Gamaliel Wibowo Soetanto, Elvan Wiyarta
    Neurology internationalPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Combined central retinal and posterior ciliary artery occlusion in a young female with primary myelofibrosis and Sweet’s syndrome: A case report
    Vikas Ambiya, Srishti Khullar, Gaurav Kapoor
    Taiwan Journal of OphthalmologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineDOAJ
  3. Pressure-Waveform Guidance for Pulmonary Vein Occlusion During Cryoballoon Ablation: Procedural Efficiency and Repeat-Procedure Findings from a Large Single-Center Cohort
    Obaida Alothman, Ahmad Keelani, Georgi Borisov +7
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Cause-specific mortality after endovascular treatment for anterior vs. posterior circulation large vessel occlusion: a multicenter cohort study
    Miao Li, Yue Wan, Yi Mo +12
    Frontiers in NeurologyPeer-reviewedCC BY 4.0Full textEpidemiology & public healthCrossrefDOAJ
  5. The influence of robotic assistance on hidden blood loss in the treatment of posterior pelvic ring injuries with sacroiliac screw fixation : A retrospective cohort study
    Ding Xu, Jing Guo, Weigang Lou +4
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
BibTeX
@article{suzuki2026influence,
  title = {{Influence of pressure sensor equipped handpiece and vitreous removal on posterior capsule movement during occlusion break in porcine eyes}},
  author = {Hisaharu Suzuki},
  journal = {Scientific Reports},
  year = {2026},
  month = sep,
  doi = {10.1038/s41598-026-73396-9},
  url = {https://doi.org/10.1038/s41598-026-73396-9},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Influence of pressure sensor equipped handpiece and vitreous removal on posterior capsule movement during occlusion break in porcine eyes
AU  - Hisaharu Suzuki
PY  - 2026
DA  - 2026/09/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-73396-9
UR  - https://doi.org/10.1038/s41598-026-73396-9
AB  - Posterior capsule stability is a key determinant of safety in phacoemulsification; however, the influence of the vitreous on its dynamics remains unclear. This non-clinical study evaluated the stabilizing effect of the Active Sentry (AS) handpiece and the impact of vitreous absence using an ex vivo vitrectomized porcine eye model. Posterior capsule elevation following an occlusion break was quantified across four vitrectomized groups (AS or Ozil [OZ] handpieces), with or without eyelid speculum [ES] and compared with previously reported vitreous-intact data from the same series using an identical protocol. At 20 mmHg intraocular pressure, the posterior capsule elevation ratio was significantly lower with the AS than with the OZ handpiece, both without ES (3.8 ± 1.3% vs. 8.4 ± 3.9%) and with ES (10.1 ± 12.3% vs. 20.0 ± 14.4%) (both P = 0.0010). Vitrectomized eyes showed reduced elevation compared with vitreous-intact eyes in the ES model: 10.1 ± 12.3% vs. 18.0 ± 19.1% with the AS (P = 0.0215) and 20.0 ± 14.4% vs. 46.2 ± 20.2% with the OZ (P = 0.0031). In conclusion, the AS handpiece stabilized the posterior capsule independently of vitreous support. Vitrectomized eyes did not show increased posterior capsule instability, and exploratory, independently sampled comparisons suggested that vitreous absence may be associated with attenuated elevation during surge events; this observation should be interpreted as hypothesis-generating.
SN  - 2045-2322
ER  -