Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) detects perfusion deficits in pediatric lung transplant recipients
8 affiliations
- 1Clinic for Pediatric Pneumology, Allergology and Neonatology, Hannover Medical School, Hannover, Germany
- 2Biomedical Research in Endstage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), Hannover, Germany
- 3Department of Diagnostic, Interventional and Pediatric Radiology, Inselspital, Bern University Hospital, University Bern, Bern, Switzerland
- 4Institute for Diagnostic and Interventional Radiology, Hannover Medical School, Hannover, Germany
- 5Department of Diagnostic and Interventional Radiology, Charité Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany
- 6Division of Pediatric Pulmonology and Allergology, Department of Pediatrics and Adolescent Medicine, Medical University of Graz, Graz, Austria
- 7Department of Respiratory Medicine, University Children’s Hospital Zurich, Zurich, Switzerland
- 8Department of Cardiothoracic, Transplant and Vascular Surgery, Hannover Medical School, Hannover, Germany
Abstract
Background: Phase-resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is a radiation-free technique that detects regional ventilation and perfusion abnormalities and has shown promise for identifying chronic lung allograft dysfunction (CLAD) in adult lung transplant (LTx) recipients. Its utility in pediatric LTx has not been investigated. We evaluated the feasibility of PREFUL MRI in pediatric LTx recipients and its association with pulmonary function.
Methods: In this single-center cross-sectional study, pediatric LTx recipients and healthy controls underwent contrast-free PREFUL MRI at 1.5 T to quantify regional ventilation and perfusion defects. Spirometry and nitrogen multiple-breath washout were performed to determine forced expiratory volume in one second (FEV₁) and lung clearance index (LCI). Group differences were assessed using the rank-sum test, and associations were analyzed using Spearman's correlation.
Results: Twenty-two of 24 eligible pediatric LTx recipients (feasibility 92%; median age 13.6 years [range 6–17]; median time since LTx 3.9 years [range 0.6–16.3]) and 11 healthy controls (median age 10.7 years [range 6–15]) completed the study. Perfusion defect extent was significantly greater in pediatric LTx recipients than in controls (p = 0.001), whereas ventilation defects did not differ (p = 0.359). No participant met spirometric criteria for CLAD. FEV₁ %predicted, but not FEV₁ % of baseline, correlated inversely with perfusion defect extent (ρ = -0.487, p = 0.022). No correlations were observed between LCI and MRI-derived ventilation or perfusion parameters.
Conclusions: PREFUL MRI is feasible in pediatric LTx recipients and detects regional perfusion abnormalities despite stable spirometry. It may provide a sensitive, radiation-free imaging biomarker for monitoring the pediatric lung allograft.
Related
- Optimizing the transition of care in pediatric kidney transplant recipients at a tertiary center: strategies to enhance autonomy and treatment adherence
- Changes in Post-Transplant Vaccine Coverage After Implementing Structured Vaccine Reviews in Pediatric Solid Organ Transplant Recipients in British Columbia, Canada: A Canadian Immunization Research Network Study.
- Ex-vivo right posterior sectionectomy for large-for-size mismatch in pediatric liver transplant recipients.
- Donor-Derived Cell-Free DNA and Donor-Specific Antibodies at the Time of Biopsy in Pediatric Kidney Transplant Recipients: A Multi-Center Analysis.
- DQA1-Derived Indirect T Cell Epitope Load Associates With Immune Injury Markers in Pediatric Liver Transplant Recipients
BibTeX
@article{carlens2026phase,
title = {{Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) detects perfusion deficits in pediatric lung transplant recipients}},
author = {Julia Carlens and Sylvia Nyilas and Andreas Voskrebenzev and Nicolaus Schwerk and Florian Singer and Fabio Ius and Diane Miriam Renz and Jens Vogel-Claussen},
journal = {JHLT Open},
year = {2026},
month = oct,
doi = {10.1016/j.jhlto.2026.100712},
url = {https://doi.org/10.1016/j.jhlto.2026.100712},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Phase resolved functional lung (PREFUL) magnetic resonance imaging (MRI) detects perfusion deficits in pediatric lung transplant recipients
AU - Julia Carlens
AU - Sylvia Nyilas
AU - Andreas Voskrebenzev
AU - Nicolaus Schwerk
AU - Florian Singer
AU - Fabio Ius
AU - Diane Miriam Renz
AU - Jens Vogel-Claussen
PY - 2026
DA - 2026/10/26
JO - JHLT Open
DO - 10.1016/j.jhlto.2026.100712
UR - https://doi.org/10.1016/j.jhlto.2026.100712
AB - Background: Phase-resolved functional lung (PREFUL) magnetic resonance imaging (MRI) is a radiation-free technique that detects regional ventilation and perfusion abnormalities and has shown promise for identifying chronic lung allograft dysfunction (CLAD) in adult lung transplant (LTx) recipients. Its utility in pediatric LTx has not been investigated. We evaluated the feasibility of PREFUL MRI in pediatric LTx recipients and its association with pulmonary function. Methods: In this single-center cross-sectional study, pediatric LTx recipients and healthy controls underwent contrast-free PREFUL MRI at 1.5 T to quantify regional ventilation and perfusion defects. Spirometry and nitrogen multiple-breath washout were performed to determine forced expiratory volume in one second (FEV₁) and lung clearance index (LCI). Group differences were assessed using the rank-sum test, and associations were analyzed using Spearman's correlation. Results: Twenty-two of 24 eligible pediatric LTx recipients (feasibility 92%; median age 13.6 years [range 6–17]; median time since LTx 3.9 years [range 0.6–16.3]) and 11 healthy controls (median age 10.7 years [range 6–15]) completed the study. Perfusion defect extent was significantly greater in pediatric LTx recipients than in controls (p = 0.001), whereas ventilation defects did not differ (p = 0.359). No participant met spirometric criteria for CLAD. FEV₁ %predicted, but not FEV₁ % of baseline, correlated inversely with perfusion defect extent (ρ = -0.487, p = 0.022). No correlations were observed between LCI and MRI-derived ventilation or perfusion parameters. Conclusions: PREFUL MRI is feasible in pediatric LTx recipients and detects regional perfusion abnormalities despite stable spirometry. It may provide a sensitive, radiation-free imaging biomarker for monitoring the pediatric lung allograft.
SN - 2950-1334
ER -