Noise Propagation and Non-Uniqueness in Three-Material Dual Energy CT with a Path Length Constraint
Abstract
Objective: Using a path length constraint with dual energy computed tomography (DECT) data, a sample can be decomposed into three basis materials. We aim to analyze the stability of such a system by presenting a noise propagation framework for optimizing the contrast to noise ratio (CNR) of virtual monochromatic images (VMIs) and by studying instances where sinogram decompositions are not unique. Approach: We extend a noise propagation framework developed for two-material DECT to three materials. Using the Jacobian of the system, we identify tube voltage pairings with good noise properties and obtain analytical expressions for VMI CNR. We apply spectral theorem to identify the best CNR possible in a linear combination of basis images. By using a reduced two-dimensional problem, we develop the sampling isoline recovery algorithm (SIRA) to study non-unique sinogram decompositions in this system. Main results: Using our noise propagation framework with a realistic breast phantom consisting of adipose, glandular tissue, and iodine, we find an ideal tube pairing of 34 kVp and 69 kVp, and a maximum VMI CNR of a spiculated lesion of 9.9. By allowing arbitrary linear combinations of basis material images, we find a CNR of 10.2 can be achieved. In a realistic phantom with a cardiac plaque, we find non-unique water, bone and iodine decompositions, and show that qualitatively accurate reconstructions can be obtained using SIRA. Significance: We developed a framework for direct optimization of VMI CNR in a three-material DECT decomposition and showed that an arbitrary linear combination of basis material images can achieve a higher CNR than a strict VMI. We demonstrate the presence of non-unique sinogram decompositions in three-material DECT with a data constraint.
Related
- Theory of Observability of Voigt-Wave Propagation in a Homogeneous Dielectric Material
- Targeted material doping to enable the formation and coherent propagation of Laser Induced Periodic Surface Structures (LIPSS): the ZnO paradigm
- High-energy uniqueness of open-string disk integrals
- Energy Transmission and Harmonic Propagation in Unidirectionally Coupled Plasma Oscillator Networks
- Hidden convexity of the Eliashberg condensation energy: existence, uniqueness and continuity of the superconducting state
BibTeX
@misc{ferretti2026noise,
title = {{Noise Propagation and Non-Uniqueness in Three-Material Dual Energy CT with a Path Length Constraint}},
author = {Andrew E. Ferretti and Emil Y. Sidky and JP Phillips and Xiaochuan Pan},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.10460},
eprint = {2611.10460},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.10460},
}
RIS
TY - UNPB
TI - Noise Propagation and Non-Uniqueness in Three-Material Dual Energy CT with a Path Length Constraint
AU - Andrew E. Ferretti
AU - Emil Y. Sidky
AU - JP Phillips
AU - Xiaochuan Pan
PY - 2026
DA - 2026/11/07
PB - arXiv
DO - 10.48550/arxiv.2611.10460
UR - https://arxiv.org/abs/2611.10460
AB - Objective: Using a path length constraint with dual energy computed tomography (DECT) data, a sample can be decomposed into three basis materials. We aim to analyze the stability of such a system by presenting a noise propagation framework for optimizing the contrast to noise ratio (CNR) of virtual monochromatic images (VMIs) and by studying instances where sinogram decompositions are not unique. Approach: We extend a noise propagation framework developed for two-material DECT to three materials. Using the Jacobian of the system, we identify tube voltage pairings with good noise properties and obtain analytical expressions for VMI CNR. We apply spectral theorem to identify the best CNR possible in a linear combination of basis images. By using a reduced two-dimensional problem, we develop the sampling isoline recovery algorithm (SIRA) to study non-unique sinogram decompositions in this system. Main results: Using our noise propagation framework with a realistic breast phantom consisting of adipose, glandular tissue, and iodine, we find an ideal tube pairing of 34 kVp and 69 kVp, and a maximum VMI CNR of a spiculated lesion of 9.9. By allowing arbitrary linear combinations of basis material images, we find a CNR of 10.2 can be achieved. In a realistic phantom with a cardiac plaque, we find non-unique water, bone and iodine decompositions, and show that qualitatively accurate reconstructions can be obtained using SIRA. Significance: We developed a framework for direct optimization of VMI CNR in a three-material DECT decomposition and showed that an arbitrary linear combination of basis material images can achieve a higher CNR than a strict VMI. We demonstrate the presence of non-unique sinogram decompositions in three-material DECT with a data constraint.
SN - 2331-8422
ER -