Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 16 min ago
Peer-reviewedCC BYFrontiers in bioengineering and biotechnology

Morphometry-based design and finite element assessment of primary stability in glenoid baseplate fixation for reverse shoulder arthroplasty for the Indian population.

  1. 1School of Electronics Engineering, Vellore Institute of Technology, Vellore, India.

Abstract

Introduction

The geometrical and morphological parameters of the glenoid vary across ethnic groups, affecting the fixation of the baseplates in reverse shoulder arthroplasty. Studies have shown that using larger baseplates for smaller glenoids may not facilitate a better biomechanical outcome, and therefore a population-based investigation plays a crucial role in selecting an appropriate implant.Methods

This work investigates finite element analysis of a pear-shaped glenoid baseplate, designed based on the morphometric parameters of the Indian glenoid. A percentile-based method was used to select the representative glenoid to select small, middle and large glenoid variations within the Indian population. Nine glenoid-baseplate assemblies were assembled from three different glenoid dimensions and three baseplate sizes. This baseplate-scapula construct was subjected to finite element analysis under specified loading conditions for various abduction angles to investigate mechanical load sharing and primary stability.Results

These findings indicated that the fixation outcomes changed based on the baseplate-glenoid assembly, showing that the biomechanical performance did not depend on the baseplate size alone.Discussion

Smaller baseplates and intermediate baseplates showed better primary stability in the Indian glenoid, supporting morphometry-guided baseplate selection based on implant-glenoid dimensional compatibility.

Related

  1. Glenoid inclination in reverse total shoulder arthroplasty with and without baseplate wedge augmentation: a retrospective comparative study
    Riki D. Wylie, Clement Chan, Jay R. Ebert +1
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Late glenosphere–baseplate Morse taper dissociation after reverse total shoulder arthroplasty with a patient-specific Vault Reconstruction System glenoid: a case report
    MiKinze L. Boeder, Jonathan P. Braman, Allison J. Rao +1
    Journal of shoulder and elbow arthroplastyPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCEurope PMCPMC
  3. Primary Total Knee Arthroplasty Using a Cementless Highly Porous Titanium Tibial Baseplate in Patients Under the Age of 50: An Average 7.6-year Follow-up
    Arun Nadar, Essa Gul, Ryan Pattyn +4
    Arthroplasty TodayPeer-reviewedCC BY-NC-NDSurgery & anaesthesiaHAL
  4. Comparative micro-computed tomography assessment of left-sided septal pouch and left atrial appendage morphometry
    Jakub Hołda, Kacper Jaśkiewicz, Jacek Tarasiuk +5
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicineCrossref
  5. Clavicle morphometry in the adult Turkish population: implications for fracture management and implant design
    Hadi Sasani, Yaşar Mahsut Dinçel, Mazhar Özkan +2
    BMC Medical ImagingPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@article{john2026morphometrybased,
  title = {{Morphometry-based design and finite element assessment of primary stability in glenoid baseplate fixation for reverse shoulder arthroplasty for the Indian population.}},
  author = {Pearline Beulah John and Sharmila Nageswaran},
  journal = {Frontiers in bioengineering and biotechnology},
  year = {2026},
  month = oct,
  doi = {10.3389/fbioe.2026.1927447},
  url = {https://europepmc.org/article/MED/42898391},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Morphometry-based design and finite element assessment of primary stability in glenoid baseplate fixation for reverse shoulder arthroplasty for the Indian population.
AU  - Pearline Beulah John
AU  - Sharmila Nageswaran
PY  - 2026
DA  - 2026/10/05
JO  - Frontiers in bioengineering and biotechnology
DO  - 10.3389/fbioe.2026.1927447
UR  - https://europepmc.org/article/MED/42898391
AB  - Introduction  The geometrical and morphological parameters of the glenoid vary across ethnic groups, affecting the fixation of the baseplates in reverse shoulder arthroplasty. Studies have shown that using larger baseplates for smaller glenoids may not facilitate a better biomechanical outcome, and therefore a population-based investigation plays a crucial role in selecting an appropriate implant.Methods  This work investigates finite element analysis of a pear-shaped glenoid baseplate, designed based on the morphometric parameters of the Indian glenoid. A percentile-based method was used to select the representative glenoid to select small, middle and large glenoid variations within the Indian population. Nine glenoid-baseplate assemblies were assembled from three different glenoid dimensions and three baseplate sizes. This baseplate-scapula construct was subjected to finite element analysis under specified loading conditions for various abduction angles to investigate mechanical load sharing and primary stability.Results  These findings indicated that the fixation outcomes changed based on the baseplate-glenoid assembly, showing that the biomechanical performance did not depend on the baseplate size alone.Discussion  Smaller baseplates and intermediate baseplates showed better primary stability in the Indian glenoid, supporting morphometry-guided baseplate selection based on implant-glenoid dimensional compatibility.
SN  - 2296-4185
ER  -