Monte Carlo-based secondary dose check platform for the world's first ultra-compact upright proton therapy system
Abstract
Objective. This work aimed to develop and validate an independent Monte Carlo (MC) secondary dose check of the RayStation treatment planning system (TPS) for the Mevion S250-FIT, the world's first ultra-compact upright proton therapy system. Approach. The treatment nozzle, including the energy modulation system of boron carbide and polycarbonate plates and the adaptive aperture, was modeled in the TOPAS (TOol for PArticle Simulation) MC code, and the beam model was commissioned against integrated depth dose curves, in-air spot profiles, and dose per monitor unit measured at 12 energy settings. Based on this model, an in-house converter, RayStation2TOPAS, recalculates the TPS plans by reconstructing each pencil beam spot, the aperture for each energy layer, and the seated patient's rotation. In total, 15 water phantom plans and 25 clinical plans were recalculated and compared with the TPS by the point dose, with a tolerance of 5%, and by three-dimensional gamma analysis at 3%/2mm, with a pass rate of at least 90%. Main results. The simulated proton range agreed with the measurement within 0.25mm, the spot full width at half maximum within 6.8%, and the dose per monitor unit within 1.3%. The point dose differed from the TPS by -0.76% to +1.98% in the water phantom plans and by -3.03% to +3.99% in the clinical plans, with gamma pass rates of 96.39% to 99.93% and 90.08% to 99.98%, so every plan passed both tests. Significance. To our knowledge, this is the first independent MC secondary dose check for the S250-FIT, and it complements measurement-based patient-specific quality assurance of its plans.
Related
- Clinical Commissioning of the First Ultra-Compact Gantry-less Upright Proton Therapy System
- Search for long-lived heavy neutral leptons in signatures with one prompt muon and a secondary vertex formed by two non-prompt muons in proton-proton collisions at √s = 13 and 13.6 TeV
- Toxicity risk in head and neck proton therapy: integrating physics, biology, and genomics.
- EP09.09 Diabetes mellitus as an independent risk factor for radiation-induced contrast enhancement and optic neuropathy after proton beam therapy in meningioma patients
- Can future reirradiation justify upfront proton therapy? An extension of model-based proton therapy selection beyond primary-course NTCP benefit
BibTeX
@misc{alakbarzade2026monte,
title = {{Monte Carlo-based secondary dose check platform for the world's first ultra-compact upright proton therapy system}},
author = {Toghrul Alakbarzade and Emir Musa Olgun and Yuan James Rao and Billy W Loo Jr and Adam Johansson and Yong Yang and Murat Surucu and Mehmet Burcin Unlu and Serdar Charyyev},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.33924},
eprint = {2611.33924},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.33924},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Monte Carlo-based secondary dose check platform for the world's first ultra-compact upright proton therapy system
AU - Toghrul Alakbarzade
AU - Emir Musa Olgun
AU - Yuan James Rao
AU - Billy W Loo Jr
AU - Adam Johansson
AU - Yong Yang
AU - Murat Surucu
AU - Mehmet Burcin Unlu
AU - Serdar Charyyev
PY - 2026
DA - 2026/11/25
PB - arXiv
DO - 10.48550/arxiv.2611.33924
UR - https://arxiv.org/abs/2611.33924
AB - Objective. This work aimed to develop and validate an independent Monte Carlo (MC) secondary dose check of the RayStation treatment planning system (TPS) for the Mevion S250-FIT, the world's first ultra-compact upright proton therapy system. Approach. The treatment nozzle, including the energy modulation system of boron carbide and polycarbonate plates and the adaptive aperture, was modeled in the TOPAS (TOol for PArticle Simulation) MC code, and the beam model was commissioned against integrated depth dose curves, in-air spot profiles, and dose per monitor unit measured at 12 energy settings. Based on this model, an in-house converter, RayStation2TOPAS, recalculates the TPS plans by reconstructing each pencil beam spot, the aperture for each energy layer, and the seated patient's rotation. In total, 15 water phantom plans and 25 clinical plans were recalculated and compared with the TPS by the point dose, with a tolerance of 5%, and by three-dimensional gamma analysis at 3%/2mm, with a pass rate of at least 90%. Main results. The simulated proton range agreed with the measurement within 0.25mm, the spot full width at half maximum within 6.8%, and the dose per monitor unit within 1.3%. The point dose differed from the TPS by -0.76% to +1.98% in the water phantom plans and by -3.03% to +3.99% in the clinical plans, with gamma pass rates of 96.39% to 99.93% and 90.08% to 99.98%, so every plan passed both tests. Significance. To our knowledge, this is the first independent MC secondary dose check for the S250-FIT, and it complements measurement-based patient-specific quality assurance of its plans.
ER -