Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study
5 affiliations
- 1Division of Obstetrics & Gynecology, Department of Clinical Science, Intervention and Technology (CLINTEC) Karolinska Institutet Stockholm Sweden
- 2Centre for Fetal Medicine Karolinska University Hospital Stockholm Sweden
- 3Translational Research Group Oulu University Hospital and Oulu University Oulu Finland
- 4St. George's Hospital and City‐St. George's University of London London UK
- 5Helsinki University Hospital and University of Helsinki Helsinki Finland
Abstract
Introduction: This study evaluated agreement between automated analysis of color tissue Doppler (cTDI) cine loops and manual spectral pulsed‐wave tissue Doppler (pwTDI) measurements of fetal cardiac cycle time intervals and myocardial velocities under normal and pathological conditions in an experimental model using fetal sheep.
Material and Methods: In 10 sheep fetuses, 25%–50% partial ascending aorta constriction was performed, and in nine, utero‐placental blood flow was reduced by maternal uterine artery occlusion. Four fetuses served as controls. Experiments were performed after 4 to 5 days recovery, and cTDI cine loops and pwTDI waveforms were sequentially obtained during baseline and during fetal hypoxemia induced by maternal hypo‐oxygenation. cTDI cine loops were processed using an automated, ECG‐independent algorithm, whereas pwTDI waveforms were manually traced to measure cardiac cycle time intervals and myocardial velocities.
Results: Fetal heart rate (FHR) showed excellent agreement between methods (intraclass correlation coefficient, ICC = 0.94). In contrast, myocardial velocities and cardiac time intervals demonstrated poor‐to‐moderate absolute agreement (ICC range 0.20–0.63). Bland–Altman analysis revealed systematic modality‐specific offsets: the automated method yielded consistently lower velocities and longer isovolumic intervals. These offsets were stable across physiological states, with no metric showing phase‐dependent changes in bias after Benjamini–Hochberg false discovery rate (FDR) correction (all q > 0.05). Despite limited absolute agreement, consistency and correlation (ICC(C,1) and Pearson r) were markedly higher than absolute agreement, indicating strong preservation of relative ranking across methods. Lin's concordance correlation coefficient (CCC) showed a similar pattern, with high concordance for FHR (CCC = 0.936) and lower concordance for most other metrics.
Conclusions: Automated cTDI is not directly interchangeable with manual pwTDI for absolute measurements of sheep fetal myocardial velocities or time intervals due to persistent modality‐specific offsets. However, the automated method provides reproducible relative tracking and stable performance across different physiological conditions. Automated cTDI is therefore well suited for longitudinal assessments when interpreted using method‐specific baselines or calibration. FHR was the only parameter demonstrating near‐interchangeable performance.
Related
- Cardiomyocyte-enriched OTUD5 alleviates pathological myocardial hypertrophy by deubiquitinating STAT3 and modulating the STAT3–PGC-1α axis
- Network Pharmacology and Experimental Evidence Indicate That Dihydrochelerythrine from Toddalia asiatica Ameliorates Pathological Features of Knee Osteoarthritis in Rats and Is Associated with PI3K/AKT Signaling.
- Fate-mapping infiltrating monocytes following experimental myocardial infarction reveals differentiation trajectories in the infarcted heart
- Integrating transcriptomic analysis and experimental validation unravels autophagy- and lactylation-related gene signatures in acute myocardial infarction.
- Dose-finding, experimental medicine evaluation of sodium valproate for the prevention of post-cardiac surgery myocardial injury
BibTeX
@article{lantto2026agreement,
title = {{Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study}},
author = {Juulia Lantto and Maria Grazia Morena and Heikki Huhta and Amar Bhide and Jonas Johnson and Juha Räsänen and Ganesh Acharya},
journal = {Acta Obstetricia et Gynecologica Scandinavica},
year = {2026},
month = aug,
doi = {10.1111/aogs.70340},
url = {https://doi.org/10.1111/aogs.70340},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Agreement between cardiac cycle time intervals and myocardial velocities measured by automated analysis of color tissue Doppler cine loops and by manual tracing of spectral pulsed‐wave tissue Doppler waveforms of sheep fetal heart under normal and pathological conditions: An experimental study
AU - Juulia Lantto
AU - Maria Grazia Morena
AU - Heikki Huhta
AU - Amar Bhide
AU - Jonas Johnson
AU - Juha Räsänen
AU - Ganesh Acharya
PY - 2026
DA - 2026/08/24
JO - Acta Obstetricia et Gynecologica Scandinavica
DO - 10.1111/aogs.70340
UR - https://doi.org/10.1111/aogs.70340
AB - Introduction: This study evaluated agreement between automated analysis of color tissue Doppler (cTDI) cine loops and manual spectral pulsed‐wave tissue Doppler (pwTDI) measurements of fetal cardiac cycle time intervals and myocardial velocities under normal and pathological conditions in an experimental model using fetal sheep. Material and Methods: In 10 sheep fetuses, 25%–50% partial ascending aorta constriction was performed, and in nine, utero‐placental blood flow was reduced by maternal uterine artery occlusion. Four fetuses served as controls. Experiments were performed after 4 to 5 days recovery, and cTDI cine loops and pwTDI waveforms were sequentially obtained during baseline and during fetal hypoxemia induced by maternal hypo‐oxygenation. cTDI cine loops were processed using an automated, ECG‐independent algorithm, whereas pwTDI waveforms were manually traced to measure cardiac cycle time intervals and myocardial velocities. Results: Fetal heart rate (FHR) showed excellent agreement between methods (intraclass correlation coefficient, ICC = 0.94). In contrast, myocardial velocities and cardiac time intervals demonstrated poor‐to‐moderate absolute agreement (ICC range 0.20–0.63). Bland–Altman analysis revealed systematic modality‐specific offsets: the automated method yielded consistently lower velocities and longer isovolumic intervals. These offsets were stable across physiological states, with no metric showing phase‐dependent changes in bias after Benjamini–Hochberg false discovery rate (FDR) correction (all q > 0.05). Despite limited absolute agreement, consistency and correlation (ICC(C,1) and Pearson r) were markedly higher than absolute agreement, indicating strong preservation of relative ranking across methods. Lin's concordance correlation coefficient (CCC) showed a similar pattern, with high concordance for FHR (CCC = 0.936) and lower concordance for most other metrics. Conclusions: Automated cTDI is not directly interchangeable with manual pwTDI for absolute measurements of sheep fetal myocardial velocities or time intervals due to persistent modality‐specific offsets. However, the automated method provides reproducible relative tracking and stable performance across different physiological conditions. Automated cTDI is therefore well suited for longitudinal assessments when interpreted using method‐specific baselines or calibration. FHR was the only parameter demonstrating near‐interchangeable performance.
SN - 0001-6349
SN - 1600-0412
ER -