A Dual-Mode Electrochemical Aptasensor for Ochratoxin A Detection in Red Wine Based on a Target-Induced Displacement Strategy
- 1Key Laboratory of Natural Medicines of the Changbai Mountain, Ministry of Education, Yanbian University, Yanji 133002, China
- 2College of Agriculture, Yanbian University, Yanji 133002, China
Abstract
Ochratoxin A (OTA) is a mycotoxin of concern in wine and food safety, highlighting the need for reliable detection in complex food matrices. In this study, a dual-mode electrochemical aptasensor was developed for OTA determination in red wine based on a target-induced displacement strategy. OTA binding to its aptamer induces dissociation of the aptamer from complementary DNA (cDNA) pre-immobilized on the electrode surface, thereby altering the interfacial environment and enabling detection by electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The sensor showed a semi-logarithmic calibration relationship over the experimentally tested OTA concentration range of 0.05–10 ng/mL. The estimated EIS limit of detection (LOD) was 0.018 ng/mL; however, this value was below the lowest tested concentration and was not experimentally validated. For DPV, 0.05 ng/mL represents the lower limit of the tested range rather than an established LOD. In spiked red wine, recoveries ranged from 94.6% to 103.9%, with relative standard deviations below 10%. The dual-mode strategy provides two readouts of the same target-induced interfacial change and offers potential for preliminary OTA screening in red wine with simplified sample pretreatment.
Related
- Single‐Step Electrochemical Aptasensor for Melatonin Detection in Unprocessed Plasma
- Scalable Multiplexed Electrochemical Aptasensor Enabled by Chitosan for Heavy Metal Ion Detection: Advancing Electrode Functionalization and Reusability
- In Silico-Guided Screening of a High-Affinity PD-L1 Aptamer for the Construction of a Sensitive Electrochemical Aptasensor.
- CRISPR/Cas12a-Based Aptasensor for Cas9 Protein Detection in Spiked Food Matrices
- An efficient hypochlorous acid fluorescence imaging strategy based on toehold-mediated strand displacement for distinguishing cancer cells from normal cells
BibTeX
@article{yu2026dualmode,
title = {{A Dual-Mode Electrochemical Aptasensor for Ochratoxin A Detection in Red Wine Based on a Target-Induced Displacement Strategy}},
author = {Xueying Yu and Zhaoxian Hou and Yi Zhi and Shuo Zhang and Yuping Wen and Zhijun Guo},
journal = {Foods},
year = {2026},
month = nov,
doi = {10.3390/foods15213940},
url = {https://doi.org/10.3390/foods15213940},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - A Dual-Mode Electrochemical Aptasensor for Ochratoxin A Detection in Red Wine Based on a Target-Induced Displacement Strategy
AU - Xueying Yu
AU - Zhaoxian Hou
AU - Yi Zhi
AU - Shuo Zhang
AU - Yuping Wen
AU - Zhijun Guo
PY - 2026
DA - 2026/11/03
JO - Foods
DO - 10.3390/foods15213940
UR - https://doi.org/10.3390/foods15213940
AB - Ochratoxin A (OTA) is a mycotoxin of concern in wine and food safety, highlighting the need for reliable detection in complex food matrices. In this study, a dual-mode electrochemical aptasensor was developed for OTA determination in red wine based on a target-induced displacement strategy. OTA binding to its aptamer induces dissociation of the aptamer from complementary DNA (cDNA) pre-immobilized on the electrode surface, thereby altering the interfacial environment and enabling detection by electrochemical impedance spectroscopy (EIS) and differential pulse voltammetry (DPV). The sensor showed a semi-logarithmic calibration relationship over the experimentally tested OTA concentration range of 0.05–10 ng/mL. The estimated EIS limit of detection (LOD) was 0.018 ng/mL; however, this value was below the lowest tested concentration and was not experimentally validated. For DPV, 0.05 ng/mL represents the lower limit of the tested range rather than an established LOD. In spiked red wine, recoveries ranged from 94.6% to 103.9%, with relative standard deviations below 10%. The dual-mode strategy provides two readouts of the same target-induced interfacial change and offers potential for preliminary OTA screening in red wine with simplified sample pretreatment.
SN - 2304-8158
ER -