Abstract

Background and purpose: The MR SIGnature MAtching (MRSIGMA) was recently proposed as a real-time free-breathing 3D MR imaging technique with an imaging latency of 148 ms. It is a powerful tool for intrafractional motion monitoring for disease sites such as those in the abdominal region. This study presents a proof-of-concept MLC tracking system for dynamic adaptation of the radiation treatment based on the real-time target localization facilitated by MRSIGMA on a 1.5 T MR-Linac. Material and methods: An MLC tracking interface was developed for integration with MRSIGMA. The centroid position of a moving target was computed in real time by MRSIGMA, which was then processed by a predictive filter to account for imaging and MLC adjustment latencies. The MLC leaves were repositioned by rigid translation. To validate the MLC tracking process, a 10 cm circular field was delivered to a moving phantom for a series of sinusoidal motions and patient motion. A clinical pancreas SBRT plan was also delivered with the patient motion trace. Results: For the circular field, geometric errors of <1.8 mm and overall system latency of < 125 ms were achieved for all motion traces. Compared to no tracking, MLC tracking remarkably improved the dosimetric accuracy for the circular field and the clinical pancreas plan, with an average Gamma passing rate increased from 87.1% to 99.9% based on a 3%/2mm criteria. Interpretation: A 3D MRI-guided MLC tracking technique was developed and validated on a clinical MR-Linac. Preliminary results demonstrated great dosimetric improvements with MLC tracking for treatments with moving targets.

Related

  1. A novel automatic real-time motion tracking method in MRI-guided radiotherapy using enhanced Tracking-Learning-Detection framework with automatic segmentation.
    Shengqi Chen, Zilin Wang, Jianrong Dai +6
    Radiation oncology (London, England)Peer-reviewedCC BY-NC-NDFull textApplied physics & instrumentationEurope PMC
  2. Just-in-time volumetric imaging: Learning 2D-3D thoracic motion models during image-guided interventions
    Nicholas Hindley
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
  3. Real-time APD-based visible light positioning system with quality-aware RSS selection and embedded tracking
    Shanxiang Zhao, Weijie Liu, Nuo Huang +2
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  4. Real-time beaconless MEMS mirror-based beam steering and tracking system for mobile underwater optical wireless communication
    Shuaiqi Chen, Weijie Liu, Nuo Huang +4
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  5. Deep Learning-based Volumetric Modulated Arc Therapy Dose Prediction with Uncertainty Quantification for Left- and Right-sided Breast Cancer: A Single-institution Feasibility Study
    Thanakorn Sukha, Chanon Puttanawarut, Nat Sirirutbunkajorn +3
    Journal of Medical PhysicsPeer-reviewedCC BY-NC-SAFull textApplied physics & instrumentationDOAJ
BibTeX
@misc{yang2026realtime,
  title = {{Real-time volumetric MRI-guided MLC tracking: A feasibility study}},
  author = {Tianyu Yang and William P Donahue and Aniket Pramanik and Victor Murray and Can Wu and Ricardo Otazo and Grace Tang},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.37832},
  eprint = {2610.37832},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.37832},
}
RIS
TY  - UNPB
TI  - Real-time volumetric MRI-guided MLC tracking: A feasibility study
AU  - Tianyu Yang
AU  - William P Donahue
AU  - Aniket Pramanik
AU  - Victor Murray
AU  - Can Wu
AU  - Ricardo Otazo
AU  - Grace Tang
PY  - 2026
DA  - 2026/10/27
PB  - arXiv
DO  - 10.48550/arxiv.2610.37832
UR  - https://arxiv.org/abs/2610.37832
AB  - Background and purpose: The MR SIGnature MAtching (MRSIGMA) was recently proposed as a real-time free-breathing 3D MR imaging technique with an imaging latency of 148 ms. It is a powerful tool for intrafractional motion monitoring for disease sites such as those in the abdominal region. This study presents a proof-of-concept MLC tracking system for dynamic adaptation of the radiation treatment based on the real-time target localization facilitated by MRSIGMA on a 1.5 T MR-Linac. Material and methods: An MLC tracking interface was developed for integration with MRSIGMA. The centroid position of a moving target was computed in real time by MRSIGMA, which was then processed by a predictive filter to account for imaging and MLC adjustment latencies. The MLC leaves were repositioned by rigid translation. To validate the MLC tracking process, a 10 cm circular field was delivered to a moving phantom for a series of sinusoidal motions and patient motion. A clinical pancreas SBRT plan was also delivered with the patient motion trace. Results: For the circular field, geometric errors of <1.8 mm and overall system latency of < 125 ms were achieved for all motion traces. Compared to no tracking, MLC tracking remarkably improved the dosimetric accuracy for the circular field and the clinical pancreas plan, with an average Gamma passing rate increased from 87.1% to 99.9% based on a 3%/2mm criteria. Interpretation: A 3D MRI-guided MLC tracking technique was developed and validated on a clinical MR-Linac. Preliminary results demonstrated great dosimetric improvements with MLC tracking for treatments with moving targets.
ER  -