High-Precision Photometry with a scientific CMOS Camera: III Lab and on-Sky testing of Andor Toran-26B

Abstract

Scientific CMOS cameras are increasingly used in modern astronomy, offering CCD-like performance with lower power use, faster readout, and reduced cost. We evaluate the photometric precision of the Toran-26B camera, featuring the IMX571 sensor from Sony, a new CMOS camera from Andor Technology, through laboratory and on-sky tests in its two modes: high well capacity (HWC) and low noise (LN). Key metrics include read noise, dark current, photo and dark signal non-uniformity, quantum efficiency, and window transmittance. The median read noise is 1.07\,e- (LN) and 2.79\,e- (HWC). Bias shows minor dark signal non-uniformity: 0.076\,e- (LN), 0.173\,e- (HWC). Pixel well depth reaches 15700\,e- (LN) and 50000\,e- (HWC), with dynamic ranges of 83.39\,dB and 85.05\,dB, respectively. Linearities are 99.93\,\% (LN) and 99.82\,\% (HWC) within the 5-95\,\% range of the saturation signal. Photo response non-uniformity is 0.076\,\% (LN) and 0.05\,\% (HWC). Dark current at 0\,∘C is 0.001\,\eps, (LN and HWC). On-sky tests show that, for our test telescope configuration, the HWC mode can be camera noise limited for specific magnitude ranges, while the LN mode remains free of such limitations, making it the preferred choice.

Related

  1. Estimator Precision and Selection for Up-the-Ramp Sampling with a High-Read-Noise InGaAs Camera
    Wei-Jie Meng, Fang-Yu Xu, Zhen-Yu Jin +1
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsarXiv
  2. gwBenchmarks: Stress-Testing LLM Agents on High-Precision Gravitational Wave Astronomy
    Tousif Islam, Digvijay Wadekar, Zihan Zhou
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsInstrumentation & methodsarXiv
  3. Photometry and analysis of comet 220P/McNaught during the 2026 outbursts
    Monthly Notices of the Royal Astronomical SocietyPeer-reviewedCC BY 4.0Solar & stellar physicsOUP
  4. A new method to cleanly separate hot and cool populations using just Gaia and 2MASS photometry
    J. Maíz Apellániz, M. Pantaleoni González
    arXivPreprintarXiv licenceFull textGalaxiesSolar & stellar physicsarXiv
  5. A Uniform Census of Variable Stars in M101 Based on HST/ACS Photometry
    Jiyu Wang, Xiaodian Chen, Pinjian Chen +3
    arXivPreprintCC BY 4.0Full textGalaxiesSolar & stellar physicsarXiv
BibTeX
@misc{apergis2026highprecision,
  title = {{High-Precision Photometry with a scientific CMOS Camera: III Lab and on-Sky testing of Andor Toran-26B}},
  author = {Ioannis Apergis and Leonidas Asimakoulas and Daniel Bayliss and Paul Chote and Morgan A. Mitchell and James McCormac and Ben Godson and Philip G. Steen},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.34182},
  eprint = {2611.34182},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.34182},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - High-Precision Photometry with a scientific CMOS Camera: III Lab and on-Sky testing of Andor Toran-26B
AU  - Ioannis Apergis
AU  - Leonidas Asimakoulas
AU  - Daniel Bayliss
AU  - Paul Chote
AU  - Morgan A. Mitchell
AU  - James McCormac
AU  - Ben Godson
AU  - Philip G. Steen
PY  - 2026
DA  - 2026/11/25
PB  - arXiv
DO  - 10.48550/arxiv.2611.34182
UR  - https://arxiv.org/abs/2611.34182
AB  - Scientific CMOS cameras are increasingly used in modern astronomy, offering CCD-like performance with lower power use, faster readout, and reduced cost. We evaluate the photometric precision of the Toran-26B camera, featuring the IMX571 sensor from Sony, a new CMOS camera from Andor Technology, through laboratory and on-sky tests in its two modes: high well capacity (HWC) and low noise (LN). Key metrics include read noise, dark current, photo and dark signal non-uniformity, quantum efficiency, and window transmittance. The median read noise is 1.07\,e^- (LN) and 2.79\,e^- (HWC). Bias shows minor dark signal non-uniformity: 0.076\,e^- (LN), 0.173\,e^- (HWC). Pixel well depth reaches 15700\,e^- (LN) and 50000\,e^- (HWC), with dynamic ranges of 83.39\,dB and 85.05\,dB, respectively. Linearities are 99.93\,\% (LN) and 99.82\,\% (HWC) within the 5-95\,\% range of the saturation signal. Photo response non-uniformity is 0.076\,\% (LN) and 0.05\,\% (HWC). Dark current at 0\,^∘C is 0.001\,\eps, (LN and HWC). On-sky tests show that, for our test telescope configuration, the HWC mode can be camera noise limited for specific magnitude ranges, while the LN mode remains free of such limitations, making it the preferred choice.
ER  -