Skip to content
DraconiticResearch
Search Sources API
194,161 studies31 sourcesUpdated 16 min ago
PreprintCC BY-NC-ND 4.0arXiv

Non-Ionizing Radiation Measurements for Trajectography Radars

Abstract

This work presents a Non-Ionizing Radiation (NIR) measurement campaign and proposes a specific measurement method for trajectography radars. This kind of radar has a high gain narrow beam antenna and emits a high power signal. Power density measurements from a C-band trajectography radar are carried out using bench equipment and a directional receiving antenna, instead of the commonly used isotropic probe. The measured power density levels are assessed for compliance test via comparison with the occupational and general public exposure limit levels of both the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Brazilian National Telecommunication Agency (Anatel). The limit for the occupational public is respected everywhere, evidencing the safe operation of the studied radar. However, the limit for the general public is exceeded at a point next to the radar's antenna, showing that preventive measures are needed.

Versions

Related

  1. Survival of dipeptides under ionizing radiation in astrophysical environments
    L. Carlini, P. Bolognesi, F. Porcelli +11
    Physical Chemistry Chemical PhysicsPeer-reviewedCC BY 4.0Full textGeneral physicsHAL
  2. Measurements of sensor radiation damage in the ATLAS inner detector using leakage currents
    Georges Aad, Braden Keim Abbott, Dale Abbott +2,864
    Journal of InstrumentationPeer-reviewedCC BYFull textHigh-energy & particle physicsHAL
  3. Study of the properties of sustainable materials for shielding against ionizing radiations
    Julien Faivre
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  4. Ionizing Photon Production Efficiencies and Chemical Abundances at Cosmic Dawn Revealed by Ultradeep Rest-frame Optical Spectroscopy of JADES-GS-z14-0
    Jakob M. Helton, Jane E. Morrison, Kevin Hainline +40
    The Astrophysical Journal LettersPeer-reviewedCC BY-NC-ND 4.0Full text21 citedCosmologyGeneral physicsHALOpenAlex
  5. Compact laser power measurement at tens of watts via amplified radiation pressure
    Atlas Rhode, Benjamin Nienhouse, Brian Simonds +2
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
BibTeX
@misc{filho2026nonionizing,
  title = {{Non-Ionizing Radiation Measurements for Trajectography Radars}},
  author = {J. Marcos Leal Barbosa Filho and Millena M. de M. Campos and Daniel L. Flor and William S. Alves and Adaildo G. D'Assunção and Marcio E. C. Rodrigues and Vicente A. de Sousa Jr},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.36164},
  eprint = {2609.36164},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.36164},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - UNPB
TI  - Non-Ionizing Radiation Measurements for Trajectography Radars
AU  - J. Marcos Leal Barbosa Filho
AU  - Millena M. de M. Campos
AU  - Daniel L. Flor
AU  - William S. Alves
AU  - Adaildo G. D'Assunção
AU  - Marcio E. C. Rodrigues
AU  - Vicente A. de Sousa Jr
PY  - 2026
DA  - 2026/09/28
PB  - arXiv
DO  - 10.48550/arxiv.2609.36164
UR  - https://arxiv.org/abs/2609.36164
AB  - This work presents a Non-Ionizing Radiation (NIR) measurement campaign and proposes a specific measurement method for trajectography radars. This kind of radar has a high gain narrow beam antenna and emits a high power signal. Power density measurements from a C-band trajectography radar are carried out using bench equipment and a directional receiving antenna, instead of the commonly used isotropic probe. The measured power density levels are assessed for compliance test via comparison with the occupational and general public exposure limit levels of both the International Commission on Non-Ionizing Radiation Protection (ICNIRP) and the Brazilian National Telecommunication Agency (Anatel). The limit for the occupational public is respected everywhere, evidencing the safe operation of the studied radar. However, the limit for the general public is exceeded at a point next to the radar's antenna, showing that preventive measures are needed.
ER  -