Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 57 min ago
Peer-reviewedCC BYAnalytical chemistry

Thin-Layer Sample-Ion-Selective Nanomembrane Architecture for Coulometric Cation Sensing.

  1. 1UCAM-SENS, Universidad Católica San Antonio de Murcia, UCAM HiTech, Avda. Andrés Hernández Ros, 1, 30107Murcia, Spain.
  2. 2Department of Chemistry, School of Engineering Science in Chemistry, Biotechnology and Health, KTH Royal Institute of Technology, Teknikrigen 30, SE-100 44Stockholm, Sweden.

Abstract

Herein, we investigate a coulometric nanomembrane-based ISE integrated into a microfluidic cell pursuing the absolute analysis of potassium ions (K+), selected as a model example. The sensor consisted of a glass substrate coated with the conducting polymer poly(3-octylthiophene) (POT) and a nanometer-sized, potassium-selective membrane casted on top. In the microfluidic cell, the sample is confined to a thin-layer domain being sandwiched between the working electrode and the counter/reference electrode. Two electrochemical protocols are developed toward exhaustive ion transfer at the membrane-sample interface: (i) an anodic mode, where K+ is first accumulated in the membrane and then released to the sample, and (ii) a cathodic mode, where ion release from the membrane is followed by a complete uptake. Tuned POT oxidation and reduction are respectively utilized as the driving force for the ultimate ion transfer to be analytically exploited, with linear sweep voltammetry (LSV) and chronoamperometry being explored as charge readout strategies. The calibration-free operation is validated for the anodic LSV protocol within a range of 1-30 μM; while other routes exhibited deviations from the 100% coulometric efficiency that may arise from several factors: (i) variations in the sample volume due to the spacer material, (ii) lateral diffusion in the microfluidic channel, and (iii) interferences. A fundamental asymmetry was observed between ion uptake and release at the membrane interface, meaning that calibration-free operation via Faradaic quantification relies heavily on the specific electrochemical protocol applied. The developed sensor was tested for the quantification of K+ in diverse matrices, including urine, blood serum, environmental water, and standard solutions, showing overall good agreement with ion chromatography when appropriate protocols were employed.

Related

  1. Horticulture acreage estimation: remote sensing vis-a-vis sample surveys
    Tauqueer Ahmad, Prachi Misra Sahoo, Ankur Biswas +2
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEcologyCrossref
  2. State-Dependent 3D Enhancer Architecture Resolves a Shared Schizophrenia and Multiple Sclerosis Ketone and Lactate Sensing Logic Gate
    B. A. Krantz
    bioRxivPreprintCC BY-NC-NDFull textImmunologybioRxiv
  3. How Many Factors Underlie the WAIS-5? Evidence From the Australian and New Zealand Standardization Sample.
    Dr. Paul Skirrow
    PsyArXivPreprintAll rights reservedFull textNeurosciencePsychiatry & mental healthOSF
  4. Sample overlap in genome-wide association meta-analysis: practical comparisons across significance thresholds
    Z. Xu, L. Zhang, L. T. Elliott
    bioRxivPreprintAll rights reservedFull textGenetics & genomicsbioRxiv
  5. When n is not enough: Assessing the interplay of spatial sampling error and sample selection in abundance estimation
    Philippe Aubry, Gwenaël Quaintenne, Matthieu Guillemain +1
    Ecological ModellingPeer-reviewedHAL deposit licenceFull textEcologyEnvironmental science & pollutionHAL
BibTeX
@article{martinezlorca2026thinlayer,
  title = {{Thin-Layer Sample-Ion-Selective Nanomembrane Architecture for Coulometric Cation Sensing.}},
  author = {Nuria Martínez-Lorca and Yujie Liu and Gastón A Crespo and María Cuartero},
  journal = {Analytical chemistry},
  year = {2026},
  month = oct,
  doi = {10.1021/acs.analchem.6c01562},
  url = {https://europepmc.org/article/MED/42915695},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Thin-Layer Sample-Ion-Selective Nanomembrane Architecture for Coulometric Cation Sensing.
AU  - Nuria Martínez-Lorca
AU  - Yujie Liu
AU  - Gastón A Crespo
AU  - María Cuartero
PY  - 2026
DA  - 2026/10/01
JO  - Analytical chemistry
DO  - 10.1021/acs.analchem.6c01562
UR  - https://europepmc.org/article/MED/42915695
AB  - Herein, we investigate a coulometric nanomembrane-based ISE integrated into a microfluidic cell pursuing the absolute analysis of potassium ions (K+), selected as a model example. The sensor consisted of a glass substrate coated with the conducting polymer poly(3-octylthiophene) (POT) and a nanometer-sized, potassium-selective membrane casted on top. In the microfluidic cell, the sample is confined to a thin-layer domain being sandwiched between the working electrode and the counter/reference electrode. Two electrochemical protocols are developed toward exhaustive ion transfer at the membrane-sample interface: (i) an anodic mode, where K+ is first accumulated in the membrane and then released to the sample, and (ii) a cathodic mode, where ion release from the membrane is followed by a complete uptake. Tuned POT oxidation and reduction are respectively utilized as the driving force for the ultimate ion transfer to be analytically exploited, with linear sweep voltammetry (LSV) and chronoamperometry being explored as charge readout strategies. The calibration-free operation is validated for the anodic LSV protocol within a range of 1-30 μM; while other routes exhibited deviations from the 100% coulometric efficiency that may arise from several factors: (i) variations in the sample volume due to the spacer material, (ii) lateral diffusion in the microfluidic channel, and (iii) interferences. A fundamental asymmetry was observed between ion uptake and release at the membrane interface, meaning that calibration-free operation via Faradaic quantification relies heavily on the specific electrochemical protocol applied. The developed sensor was tested for the quantification of K+ in diverse matrices, including urine, blood serum, environmental water, and standard solutions, showing overall good agreement with ion chromatography when appropriate protocols were employed.
SN  - 0003-2700
SN  - 1520-6882
ER  -