Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 31 min ago
PreprintCC BY 4.0arXiv

Replayable Monte Carlo MRI: From Persistent Tissue Microphysics to Queryable Virtual Phantoms

Abstract

Multiphysics Monte Carlo simulation is the reference method for diffusion MRI in idealized tissue: walkers diffuse through a numerical substrate with relaxation, permeability, susceptibility and magnetization transfer, and accumulate the signal of a prescribed acquisition. Yet walker histories are massive, petabytes for a tractography-scale phantom, so current simulators treat them as transient. They are regenerated for every new acquisition, field strength or relaxation rate, although identical for all of them. I propose to keep these histories instead as a replay pack, compressed into persistent, shareable tissue microphysics, so that any such query is a cheap inner product against the pack. By storing each path as a Brownian bridge cut to the band a scanner class can play, transform coding its coefficients and contracting them into time segments, a replay pack is up to 5000 times smaller than the histories it keeps, while staying within the Monte-Carlo floor for every waveform of that class. It matches analytical solutions in pores, and MC/DC and MCMRSimulator on realistic axon meshes. At the scale of the field's largest benchmark, I re-simulate DiSCo, the billion-walker Monte Carlo tractography phantom, as a multiphysics replay phantom. It reproduces the published protocol's signal to one percent, and any waveform, relaxation or susceptibility up to 100 ms is a query of the same replay pack. I release every replay pack of this paper on the SubstrateCommons Hugging Face Hub and deploy replayable DiSCo as a public Hugging Face Space (https://huggingface.co/spaces/rfick/disco-replay), where anyone can choose an acquisition type (PGSE, OGSE, PGSTE or tensor encoding) and the tissue's parameters, and within two minutes receive their multiphysics Monte Carlo diffusion-weighted image volumes. With replay, a Monte Carlo simulation becomes an instrument anyone can query, at scale.

Related

  1. evaluating local viscoelastic properties of artery-mimicking phantoms using high-resolution flexural wavenumber analysis
    Max Gattin, Julien de Rosny
    arXivPreprintarXiv licenceFull textBiological & medical physicsCondensed matterarXiv
  2. Fail-closed conformal multiresolution error control for conservative three-dimensional dose remapping in synthetic phantoms
    Yuntao Wang
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
  3. Physics-informed self-supervised generation of digital brain MRI phantoms from weighted images using differentiable MRI simulation
    Kseniya Belousova, Anna Konanykhina, Zilya Murzina +2
    arXivPreprintarXiv licenceFull textBiological & medical physicsarXiv
  4. Collider Probes of Dark Energy Microphysics
    Chaitanya Bashyam, Alfredo Gurrola, Andres Florez +1
    arXivPreprintarXiv licenceFull textCosmologyGravitation & general relativityarXiv
  5. Dual-focal display through polarization-directed birefringence for compact virtual reality
    Jiaping Sun, Dewen Cheng, Jianghao Xiong +1
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
BibTeX
@misc{fick2026replayable,
  title = {{Replayable Monte Carlo MRI: From Persistent Tissue Microphysics to Queryable Virtual Phantoms}},
  author = {Rutger H. J. Fick},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.01758},
  eprint = {2611.01758},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.01758},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Replayable Monte Carlo MRI: From Persistent Tissue Microphysics to Queryable Virtual Phantoms
AU  - Rutger H. J. Fick
PY  - 2026
DA  - 2026/11/01
PB  - arXiv
DO  - 10.48550/arxiv.2611.01758
UR  - https://arxiv.org/abs/2611.01758
AB  - Multiphysics Monte Carlo simulation is the reference method for diffusion MRI in idealized tissue: walkers diffuse through a numerical substrate with relaxation, permeability, susceptibility and magnetization transfer, and accumulate the signal of a prescribed acquisition. Yet walker histories are massive, petabytes for a tractography-scale phantom, so current simulators treat them as transient. They are regenerated for every new acquisition, field strength or relaxation rate, although identical for all of them. I propose to keep these histories instead as a replay pack, compressed into persistent, shareable tissue microphysics, so that any such query is a cheap inner product against the pack. By storing each path as a Brownian bridge cut to the band a scanner class can play, transform coding its coefficients and contracting them into time segments, a replay pack is up to 5000 times smaller than the histories it keeps, while staying within the Monte-Carlo floor for every waveform of that class. It matches analytical solutions in pores, and MC/DC and MCMRSimulator on realistic axon meshes. At the scale of the field's largest benchmark, I re-simulate DiSCo, the billion-walker Monte Carlo tractography phantom, as a multiphysics replay phantom. It reproduces the published protocol's signal to one percent, and any waveform, relaxation or susceptibility up to 100 ms is a query of the same replay pack. I release every replay pack of this paper on the SubstrateCommons Hugging Face Hub and deploy replayable DiSCo as a public Hugging Face Space (https://huggingface.co/spaces/rfick/disco-replay), where anyone can choose an acquisition type (PGSE, OGSE, PGSTE or tensor encoding) and the tissue's parameters, and within two minutes receive their multiphysics Monte Carlo diffusion-weighted image volumes. With replay, a Monte Carlo simulation becomes an instrument anyone can query, at scale.
ER  -