An Indirect Comparison of Platelet-Rich Plasma Versus Patch Augmentation Versus Bone Marrow Stimulation as Rotator Cuff Repair Augmentation Techniques: A Network Meta-analysis of Randomized Controlled Trials
- 1Department of Orthopaedic Surgery, University of Colorado School of Medicine, Aurora, Colorado, USA
Abstract
Background: Platelet-rich plasma (PRP), patch augmentation (PA), and bone marrow stimulation (BMS) are 3 adjuncts that are used in the context of rotator cuff repair (RCR) to enhance the repair construct and promote healing. Purpose: To compare the clinical efficacy in the RCR augmentation techniques of PA, PRP, and BMS and determine whether any superiority is observed. Study Design: Systematic review and network meta-analysis; Level of evidence, 2. Methods: A systematic review was performed by searching PubMed, the Cochrane Library, and Embase to identify level 1 and 2 studies that compared the clinical efficacy of RCR alone versus RCR with PA, RCR with PRP, or RCR with BMS. The search phrase used was rotator cuff repair AND (patch OR augmentation OR bioinductive OR implant OR PRP OR platelet rich plasma OR platelet-rich plasma OR “bone marrow stimulation” OR “bone channeling” OR “microfracture” OR “crimson duvet” OR “bms”) . Patients were assessed based on the visual analog scale (VAS) for pain, the Constant-Murley (CM) score, the American Shoulder and Elbow (ASES) score, the University of California–Los Angeles (UCLA) shoulder score, and retear rates. Results: A total of 40 studies (level of evidence 1 or 2) met inclusion criteria, including 403 patients undergoing RCR with PA (mean age, 59.5 years), 692 patients undergoing RCR with PRP (mean age, 57.8 years), and 535 patients undergoing RCR with BMS (mean age, 59.7 years). The mean follow-up was 21.1 months in the PA group, 20.3 months in the PRP group, and 22.1 months in the BMS group. Compared with RCR alone, no significant improvements were seen in VAS, CM, ASES, and UCLA scores of each of the 3 augmentation techniques; however, PRP and PA were significantly associated with decreased retear rates. Post hoc analyses demonstrated no significant difference between BMS and PRP, BMS and PA, and PA and PRP in all reported outcomes. Conclusion: Compared with RCR with no augmentation, PA, PRP, and BMS were not associated with significantly improved patient-reported and functional outcomes; however, PA and PRP were associated with significantly reduced retear rates after RCR. The use of RCR augmentation techniques is yet to be justified, and future studies with longer follow-up periods are suggested to determine the efficacy of augmenting RCR.
Related
- Comparison of bone augmentation techniques in the mandibular posterior region: A randomized clinical trial protocol
- Comparison of dexmedetomidine and droperidol-fentanyl for asleep-awake-asleep techniques in awake craniotomy anesthesia: a randomized controlled study.
- Comparison of direct versus temporal eyebrow lift techniques: protocol for a randomized clinical trial
- Crestal Versus Lateral Window Approaches for Maxillary Sinus Floor Augmentation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials
- Closed Versus Open Vent Port Techniques and the Disconnection Technique for Optimizing Lung Collapse With Bronchial Blockers in Video‐Assisted Thoracoscopic Surgery: A Randomized Controlled Trial
BibTeX
@article{lim2026indirect,
title = {{An Indirect Comparison of Platelet-Rich Plasma Versus Patch Augmentation Versus Bone Marrow Stimulation as Rotator Cuff Repair Augmentation Techniques: A Network Meta-analysis of Randomized Controlled Trials}},
author = {Joseph J. Lim MS and Emilea A. Stepaniuk BA and Kindyll Wetta BA and John W. Belk MD and Carson Keeter MS and Adam J. Seidl MD and Rachel M. Frank MD and Jonathan T. Bravman MD and Eric C. McCarty MD},
journal = {Orthopaedic Journal of Sports Medicine},
year = {2026},
month = nov,
doi = {10.1177/23259671261492845},
url = {https://doi.org/10.1177/23259671261492845},
note = {CC BY},
}
RIS
TY - JOUR
TI - An Indirect Comparison of Platelet-Rich Plasma Versus Patch Augmentation Versus Bone Marrow Stimulation as Rotator Cuff Repair Augmentation Techniques: A Network Meta-analysis of Randomized Controlled Trials
AU - Joseph J. Lim MS
AU - Emilea A. Stepaniuk BA
AU - Kindyll Wetta BA
AU - John W. Belk MD
AU - Carson Keeter MS
AU - Adam J. Seidl MD
AU - Rachel M. Frank MD
AU - Jonathan T. Bravman MD
AU - Eric C. McCarty MD
PY - 2026
DA - 2026/11/19
JO - Orthopaedic Journal of Sports Medicine
DO - 10.1177/23259671261492845
UR - https://doi.org/10.1177/23259671261492845
AB - Background: Platelet-rich plasma (PRP), patch augmentation (PA), and bone marrow stimulation (BMS) are 3 adjuncts that are used in the context of rotator cuff repair (RCR) to enhance the repair construct and promote healing. Purpose: To compare the clinical efficacy in the RCR augmentation techniques of PA, PRP, and BMS and determine whether any superiority is observed. Study Design: Systematic review and network meta-analysis; Level of evidence, 2. Methods: A systematic review was performed by searching PubMed, the Cochrane Library, and Embase to identify level 1 and 2 studies that compared the clinical efficacy of RCR alone versus RCR with PA, RCR with PRP, or RCR with BMS. The search phrase used was rotator cuff repair AND (patch OR augmentation OR bioinductive OR implant OR PRP OR platelet rich plasma OR platelet-rich plasma OR “bone marrow stimulation” OR “bone channeling” OR “microfracture” OR “crimson duvet” OR “bms”) . Patients were assessed based on the visual analog scale (VAS) for pain, the Constant-Murley (CM) score, the American Shoulder and Elbow (ASES) score, the University of California–Los Angeles (UCLA) shoulder score, and retear rates. Results: A total of 40 studies (level of evidence 1 or 2) met inclusion criteria, including 403 patients undergoing RCR with PA (mean age, 59.5 years), 692 patients undergoing RCR with PRP (mean age, 57.8 years), and 535 patients undergoing RCR with BMS (mean age, 59.7 years). The mean follow-up was 21.1 months in the PA group, 20.3 months in the PRP group, and 22.1 months in the BMS group. Compared with RCR alone, no significant improvements were seen in VAS, CM, ASES, and UCLA scores of each of the 3 augmentation techniques; however, PRP and PA were significantly associated with decreased retear rates. Post hoc analyses demonstrated no significant difference between BMS and PRP, BMS and PA, and PA and PRP in all reported outcomes. Conclusion: Compared with RCR with no augmentation, PA, PRP, and BMS were not associated with significantly improved patient-reported and functional outcomes; however, PA and PRP were associated with significantly reduced retear rates after RCR. The use of RCR augmentation techniques is yet to be justified, and future studies with longer follow-up periods are suggested to determine the efficacy of augmenting RCR.
SN - 2325-9671
ER -