Thermal Stresses Analysis of a Circular Tube in a Central Receiver
Abstract
The tubes of central receiver power plants are designed to work under very demanding conditions, with heat fluxes varying between 0.2 to 1 MW/m 2 , depending on both the weather conditions and the operating regime of the plant. Also, the heat flux is localized along the circumferential coordinate of the tube, on the outward facing side of the tube. This results in a non-uniform temperature distribution with strong gradients both in the heat transfer fluid and the pipe walls. Predicting this distribution is important since it can induce high thermal stresses on the pipe walls and it is a key factor for the fluid decomposition. In this work we have studied different configurations to analyze the effects of tube diameter and wall thickness in the temperature distributions in the fluid and solid, for a typical concentrated solar heat flux distribution. HITEC salt and 316L stainless steel have been used as the heat transfer fluid and the material of the tubes in the receiver, respectively. A numerical method has been used to calculate the temperature distribution of the fluid and the convection coefficient along the circumference. Finally the Von-Mises thermal stresses of the tube receiver have been calculated.
Related
- Bayesian greedy receiver for pulse position modulation without an error floor under thermal noise
- Optimization of curved vortex generator geometry for enhanced thermal performance in water-to-air finned-tube heat exchanger
- Near-thermal state and thermodynamic response of a QCD system in ultra-central heavy-ion collisions
- Novel method of evaluating common mode rejection ratio in digital coherent receiver using broadband light source
- Sensitivity Enhancement of S-Band Rydberg Atom Microwave Receiver Enabled by Resonant Cavity Field Confinement
BibTeX
@article{flores2026thermal,
title = {{Thermal Stresses Analysis of a Circular Tube in a Central Receiver}},
author = {Oscar Flores and C. Marugán-Cruz and D. Santana and M. García-Villalba},
journal = {Energy Procedia},
year = {2026},
month = oct,
doi = {10.1016/j.egypro.2014.03.038},
url = {https://hal.science/hal-05781444v1},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Thermal Stresses Analysis of a Circular Tube in a Central Receiver
AU - Oscar Flores
AU - C. Marugán-Cruz
AU - D. Santana
AU - M. García-Villalba
PY - 2026
DA - 2026/10/06
JO - Energy Procedia
DO - 10.1016/j.egypro.2014.03.038
UR - https://hal.science/hal-05781444v1
AB - The tubes of central receiver power plants are designed to work under very demanding conditions, with heat fluxes varying between 0.2 to 1 MW/m 2 , depending on both the weather conditions and the operating regime of the plant. Also, the heat flux is localized along the circumferential coordinate of the tube, on the outward facing side of the tube. This results in a non-uniform temperature distribution with strong gradients both in the heat transfer fluid and the pipe walls. Predicting this distribution is important since it can induce high thermal stresses on the pipe walls and it is a key factor for the fluid decomposition. In this work we have studied different configurations to analyze the effects of tube diameter and wall thickness in the temperature distributions in the fluid and solid, for a typical concentrated solar heat flux distribution. HITEC salt and 316L stainless steel have been used as the heat transfer fluid and the material of the tubes in the receiver, respectively. A numerical method has been used to calculate the temperature distribution of the fluid and the convection coefficient along the circumference. Finally the Von-Mises thermal stresses of the tube receiver have been calculated.
SN - 1876-6102
ER -