Skip to content
DraconiticResearch
Search Sources API
190,332 studies31 sourcesUpdated 4 min ago
Peer-reviewedCC BYTechnisches Messen

Radon Sensor Networks for Large Buildings: Balancing the Trade-Off between Energy Efficiency and Health

Abstract

Radon ( 222 Rn) is a radioactive noble gas that is formed in the decay of the primordial 238 U decay chain, with an average abundance of 3 parts per million (3 g ⋅ t −1 ) in the earth’s crust. Since radon is the only noble gas in the decay chain, it has with its half live T 1 2 T1/2 = 3.8232(8) d, the ability to emanate from the ground or building materials and to interfere with the biosphere. Taking into account Directive 2013/59/Euratom, the EURAMET EPM project RadonNET was founded to find a trade-off between energy efficiency and health effects by means of measurements with small uncertainties. With this in mind, an pulse ionization chamber for the time-resolved measurement of radon activity at low concentrations is described here. The solution shown is characterized by low sensitivity to room and impact noise. Experimental investigations show the properties of the pulse ionization chamber under various conditions, particularly with regard to its use in sensor networks in larger buildings or future cities.

Related

  1. Transverse Numerical Approach Combining Fluid-Structure Interaction and Model Reduction Methods of a Modular Thermal Energy Storage System to Improve the Energy Efficiency of District Heating Networks
    Alexandre Godin, Fabien Salmon, Adeline Perro +5
    SSRN ElsevierPreprintLicence not statedGeneral physicsHAL
  2. Assessment of wind energy potential of buildings by CFD simulation in dense urban environments - From Case Studies to a Dendrogram-Based Design Framework
    David Serero, Lo{ï}c Couton, Jean-Denis Parisse +1
    arXivPreprintarXiv licenceFull textFluid dynamicsarXiv
  3. Self-Pulsing Microring Resonator Networks for Bandwidth-Efficient Event Detection in an Optical Fiber Sensor
    Alessio Lugnan, Yonas Seifu Muanenda, Ilya Auslender +4
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationOptics & photonicsarXiv
  4. Data of a triboelectric energy harvester in low frequency environment and its potential as a power source in a wireless sensor node
    Marios Kaminiotis, Julien Le Scornec, Romain Noël +2
    Data in BriefPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationHAL
  5. Fundamental Bounds on the Oscillation Efficiency of Markov Networks
    Chen Jia
    arXivPreprintarXiv licenceFull textSystems & synthetic biologyStatistical & nonlinear physicsarXiv
BibTeX
@article{sabot2026radon,
  title = {{Radon Sensor Networks for Large Buildings: Balancing the Trade-Off between Energy Efficiency and Health}},
  author = {Benoit Sabot},
  journal = {Technisches Messen},
  year = {2026},
  month = sep,
  doi = {10.1515/teme-2025-0036},
  url = {https://cea.hal.science/cea-05746133v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Radon Sensor Networks for Large Buildings: Balancing the Trade-Off between Energy Efficiency and Health
AU  - Benoit Sabot
PY  - 2026
DA  - 2026/09/10
JO  - Technisches Messen
DO  - 10.1515/teme-2025-0036
UR  - https://cea.hal.science/cea-05746133v1
AB  - Radon ( 222 Rn) is a radioactive noble gas that is formed in the decay of the primordial 238 U decay chain, with an average abundance of 3 parts per million (3 g ⋅ t −1 ) in the earth’s crust. Since radon is the only noble gas in the decay chain, it has with its half live T 1 2 T_1/2 = 3.8232(8) d, the ability to emanate from the ground or building materials and to interfere with the biosphere. Taking into account Directive 2013/59/Euratom, the EURAMET EPM project RadonNET was founded to find a trade-off between energy efficiency and health effects by means of measurements with small uncertainties. With this in mind, an pulse ionization chamber for the time-resolved measurement of radon activity at low concentrations is described here. The solution shown is characterized by low sensitivity to room and impact noise. Experimental investigations show the properties of the pulse ionization chamber under various conditions, particularly with regard to its use in sensor networks in larger buildings or future cities.
SN  - 0171-8096
ER  -