Electronic structure and multiscale modelling of the hydroxyapatite–TiO2 bio-interface: from self-interaction error to predictive coating design
- 1Department of Physics, Hafiz Hayat Campus, University of Gujrat Gujrat Pakistan
- 2Department of Physics, Gachon University 1342 Seongnam-daero, Sujeong-gu Seongnam-si Gyeonggi-do South Korea
Abstract
Hydroxyapatite–titanium dioxide (HA–TiO2) heterojunction coatings are commonly applied to enhance the osseointegration of load-bearing orthopedic implants, but their clinical performance is limited due to coating delamination and fibrous tissue encapsulation at the implant–bone interface. Density functional theory (DFT) offers excellent pre-synthesis predictions on HA–TiO2-based designs, but self-interaction error (SIE) remains a major hurdle due to the well-known underestimation of the band gaps of TiO2 and oxygen vacancy formation kinetics. This leads to inaccurate predictions of localized oxidative stress, electron transport, and early-stage corrosion at the interface. A comprehensive review of the accuracy-cost trade-off of DFT+U, hybrid functionals (HSE06), and machine-learning interatomic potentials (MLIPs) for modelling the HA–TiO2 interface is given here. The electronic-structure corrections related to mesoscale phenomena accessible by molecular dynamics (MD) are also described. A systematic description of the stiff, ice-like hydration layer formed at the TiO2 surfaces is provided to shed light on the transport of Ca2+ and PO43− during biomineralization. Further, the dynamics of the hydroxyl dipoles, doping and nanostructuring that affect the nature and strength of the resulting interfacial adhesion energy are elaborated in detail. This multiscale approach that connects the accuracy of the electronic structure with the mesoscale hydration and ion-transport kinetics offers a physics-based, computationally informed path to the rational design of HA–TiO2 biomaterial coatings.
Related
- Multiscale Design of Interaction-Driven Superlattice Assembly in Nanocomposite Tectons.
- Molecular insights into the selective interaction of endocrine-disrupting chemicals with poly(mannuronate) in aqueous systems: a multiscale computational study
- Metal‐Support Interaction Triggered Electronic Reconstruction in Pd/CoN‐Co 4 N Catalysts for Optimizing MEK Oxidation and Poisoning Resistance
- VIBE-QC: an open-source, general-purpose electronic-structure code for molecules and solids developed with generative AI
- Electronic Descriptors Lower Oxygen-Vacancy Formation-Energy Error Relative to Crystal Structure Alone in Non-Magnetic Oxides
BibTeX
@article{shahid2026electronic,
title = {{Electronic structure and multiscale modelling of the hydroxyapatite–TiO2 bio-interface: from self-interaction error to predictive coating design}},
author = {Emaan Shahid and Harram Najum and Muhammad Tayyab Raza and Abdul Majid},
journal = {RSC Advances},
year = {2026},
month = oct,
doi = {10.1039/d6ra08442g},
url = {https://doi.org/10.1039/d6ra08442g},
note = {CC BY 3.0},
}
RIS
TY - JOUR
TI - Electronic structure and multiscale modelling of the hydroxyapatite–TiO2 bio-interface: from self-interaction error to predictive coating design
AU - Emaan Shahid
AU - Harram Najum
AU - Muhammad Tayyab Raza
AU - Abdul Majid
PY - 2026
DA - 2026/10/09
JO - RSC Advances
DO - 10.1039/d6ra08442g
UR - https://doi.org/10.1039/d6ra08442g
AB - Hydroxyapatite–titanium dioxide (HA–TiO2) heterojunction coatings are commonly applied to enhance the osseointegration of load-bearing orthopedic implants, but their clinical performance is limited due to coating delamination and fibrous tissue encapsulation at the implant–bone interface. Density functional theory (DFT) offers excellent pre-synthesis predictions on HA–TiO2-based designs, but self-interaction error (SIE) remains a major hurdle due to the well-known underestimation of the band gaps of TiO2 and oxygen vacancy formation kinetics. This leads to inaccurate predictions of localized oxidative stress, electron transport, and early-stage corrosion at the interface. A comprehensive review of the accuracy-cost trade-off of DFT+U, hybrid functionals (HSE06), and machine-learning interatomic potentials (MLIPs) for modelling the HA–TiO2 interface is given here. The electronic-structure corrections related to mesoscale phenomena accessible by molecular dynamics (MD) are also described. A systematic description of the stiff, ice-like hydration layer formed at the TiO2 surfaces is provided to shed light on the transport of Ca2+ and PO43− during biomineralization. Further, the dynamics of the hydroxyl dipoles, doping and nanostructuring that affect the nature and strength of the resulting interfacial adhesion energy are elaborated in detail. This multiscale approach that connects the accuracy of the electronic structure with the mesoscale hydration and ion-transport kinetics offers a physics-based, computationally informed path to the rational design of HA–TiO2 biomaterial coatings.
SN - 2046-2069
ER -