A transformer analysis lowers the energy threshold and improves the sensitivity of a compact imaging atmospheric Cherenkov telescope
Abstract
Context. A companion study simulated an idealised stand-alone imaging atmospheric Cherenkov telescope with a 5 m diameter mirror. A video vision transformer that processes the raw camera waveforms lowered its energy threshold by a factor of three, compared with the standard analysis based on image parameters. Aims. We use realistic photodetectors, compute the differential flux sensitivity, and study how hardware parameters affect the transformer analysis. Methods. With the simulation tools of the Cherenkov Telescope Array Observatory, we compare three photodetector efficiencies (100 %, 50 % and that of the LST-1 photomultipliers) with the transformer and with a standard analysis optimised for each. We then vary the dish diameter, field of view, pulse width and sampling rate. Results. With the LST-1 photomultipliers, the energy threshold is 0.18 TeV with the transformer and 0.73 TeV with the standard analysis. The standard analysis needs a photodetector efficiency of 100 % to match that threshold. The main reason is that the transformer works with events of about 35 photoelectrons in the camera, whereas the standard analysis needs about 200 before image cleaning. A 4 m dish with the transformer is more sensitive at all energies than a 5 m dish with the standard analysis. Dishes of 4, 5 and 6 m diameter give thresholds of 0.38, 0.18 and 0.13 TeV. Sampling the pixel signals at 2 GS/s instead of 5 GS/s raises the threshold to 0.26 TeV, whereas the single-photoelectron pulse width (1-3 ns) matters little. Conclusions. The analysis matters as much as the mirror area and the photodetector efficiency. With the transformer analysis, the idealised 5 m diameter telescope comes within a factor of about four of the sensitivity of LST-1 and MAGIC above 0.25 TeV, although its mirror area is 21 times smaller than that of the 23 m LST-1. This performance should improve substantially in the coming years.
Related
- Enhancing the Angular Resolution of Large Array of imaging atmospheric Cherenkov Telescope (LACT) at Ultra-High Energies
- The Analysis, not the Aperture: End-to-End Transformer Reconstruction for Imaging Atmospheric Cherenkov Telescopes
- CtaAgnVar : a Pipeline for Variability Studies with the Cherenkov Telescope Array Observatory
- Investigation of magnetic-field effects on photomultiplier tubes for the first Large-Sized Telescope of the Cherenkov Telescope Array Observatory
- A method for enhanced gamma-proton discrimination with imaging atmospheric Cherenkov telescopes
BibTeX
@misc{jobst2026transformer,
title = {{A transformer analysis lowers the energy threshold and improves the sensitivity of a compact imaging atmospheric Cherenkov telescope}},
author = {Elli Jobst and David Paneque and Lukas Heinrich},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.23047},
eprint = {2611.23047},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.23047},
}
RIS
TY - UNPB
TI - A transformer analysis lowers the energy threshold and improves the sensitivity of a compact imaging atmospheric Cherenkov telescope
AU - Elli Jobst
AU - David Paneque
AU - Lukas Heinrich
PY - 2026
DA - 2026/11/17
PB - arXiv
DO - 10.48550/arxiv.2611.23047
UR - https://arxiv.org/abs/2611.23047
AB - Context. A companion study simulated an idealised stand-alone imaging atmospheric Cherenkov telescope with a 5 m diameter mirror. A video vision transformer that processes the raw camera waveforms lowered its energy threshold by a factor of three, compared with the standard analysis based on image parameters. Aims. We use realistic photodetectors, compute the differential flux sensitivity, and study how hardware parameters affect the transformer analysis. Methods. With the simulation tools of the Cherenkov Telescope Array Observatory, we compare three photodetector efficiencies (100 %, 50 % and that of the LST-1 photomultipliers) with the transformer and with a standard analysis optimised for each. We then vary the dish diameter, field of view, pulse width and sampling rate. Results. With the LST-1 photomultipliers, the energy threshold is 0.18 TeV with the transformer and 0.73 TeV with the standard analysis. The standard analysis needs a photodetector efficiency of 100 % to match that threshold. The main reason is that the transformer works with events of about 35 photoelectrons in the camera, whereas the standard analysis needs about 200 before image cleaning. A 4 m dish with the transformer is more sensitive at all energies than a 5 m dish with the standard analysis. Dishes of 4, 5 and 6 m diameter give thresholds of 0.38, 0.18 and 0.13 TeV. Sampling the pixel signals at 2 GS/s instead of 5 GS/s raises the threshold to 0.26 TeV, whereas the single-photoelectron pulse width (1-3 ns) matters little. Conclusions. The analysis matters as much as the mirror area and the photodetector efficiency. With the transformer analysis, the idealised 5 m diameter telescope comes within a factor of about four of the sensitivity of LST-1 and MAGIC above 0.25 TeV, although its mirror area is 21 times smaller than that of the 23 m LST-1. This performance should improve substantially in the coming years.
ER -