Diagnostic Accuracy of Fine-Needle Aspiration Cytology Alone and With Cell Block Preparation for Palpable Breast Lesions: A Prospective Study in Central India

  1. 1Department of Pathology, People’s College of Medical Sciences & Research Centre, Bhopal, IND
  2. 2Department of Physiology, People’s College of Medical Sciences & Research Centre, Bhopal, IND

Abstract

Background Fine-needle aspiration cytology (FNAC) is a rapid and minimally invasive test for palpable breast lesions, but limited architecture and sampling variability can reduce sensitivity. Cell block preparation may complement smears by preserving tissue fragments in paraffin sections. This study estimated the diagnostic accuracy of FNAC and the incremental diagnostic yield obtained by adding cell block interpretation in the histologically verified subset, while describing cell block adequacy in the entire enrolled cohort. Materials and methods This prospective observational diagnostic accuracy study enrolled 74 consecutive patients with palpable breast lesions at a tertiary-care center in Bhopal, India, from May 2024 through December 2025. A first dedicated pass was used for conventional smears and a second for plasma-thrombin cell block preparation. FNAC was classified using the International Academy of Cytology Yokohama system. Histopathology was available for 46 clinically biopsied or excised lesions and served as the reference standard. Exact 95% confidence intervals were calculated from the two-by-two counts, and FNAC and combined interpretation were compared using an exact two-sided McNemar test among the 46 verified participants. Results The mean age was 36.4 ± 14.0 years, and 70 participants (94.6%) were female. All FNAC smears were adequate; 58 lesions (78.4%) were benign, 1 (1.4%) atypical, 5 (6.8%) suspicious, and 10 (13.5%) malignant. Ten cell blocks (13.5%) were inadequate or hemorrhagic. Histopathology identified 35 benign and 11 malignant lesions. FNAC yielded 81.82% sensitivity (95% CI, 48.22%-97.72%), 100% specificity (95% CI, 90.00%-100%), and 95.65% accuracy (95% CI, 85.16%-99.47%). Combined interpretation yielded 90.91% sensitivity (95% CI, 58.72%-99.77%), 100% specificity (95% CI, 90.00%-100%), and 97.83% accuracy (95% CI, 88.47%-99.94%). Paired analysis showed one discordant result favoring combined interpretation and none favoring FNAC (exact McNemar p = 1.000). Conclusions Combined interpretation showed numerically higher sensitivity and accuracy than FNAC alone in the histologically verified subset, but the small number of malignant lesions, wide confidence intervals, and partial verification preclude a definitive claim of superiority. Cell blocks are best used as an adjunct within clinical-radiological-pathological correlation; discordant or concerning lesions still require histopathology.

Related

  1. Diagnostic Accuracy of Fine Needle Aspiration Cytology in Thyroid Diseases: Comparison with Histopathological Findings in Hawassa, Ethiopia
    A. M. Nisro, T. T. Geremew, A. K. Tadele +5
    medRxivPreprintCC BYFull textEndocrinology & metabolismmedRxiv
  2. Combined Liquid-Based and Cell-Block Urinary Cytology for Detection of High-Grade Urothelial Carcinoma of the Bladder and Upper Urinary Tract: A Prospective Pilot Diagnostic Accuracy Study
    Jan Łaszkiewicz, Artur Lipiński, Łukasz Nowak +8
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Cytology smears from endobronchial ultrasound-guided transbronchial needle aspiration as a source of nucleic acids with adequate yield for next-generation sequencing
    Asuka Uebayashi, Hideaki Furuse, Yuji Matsumoto +4
    Journal of thoracic diseasePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  4. Diagnostic Performance of Color Doppler Ultrasound for Detecting Nuchal Cord and Associated Immediate Neonatal Outcomes at Term in Uganda: A Prospective Diagnostic‐Accuracy Cohort Study
    Fiona Asiimwe, Theoneste Hakizimana, Marie Pascaline Sabine Ishimwe +10
    Health science reportsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Disseminated Sporotrichosis Diagnosed on Fine Needle Aspiration Cytology - A Report of Two Cases
    Amita K, Kuditipadi Narayana Tejashwini, Sanjay M
    Online Journal of Health & Allied SciencesPeer-reviewedCC BY-NDFull textGeneral medicineDOAJ
BibTeX
@article{shukla2026diagnostic,
  title = {{Diagnostic Accuracy of Fine-Needle Aspiration Cytology Alone and With Cell Block Preparation for Palpable Breast Lesions: A Prospective Study in Central India}},
  author = {Khushboo Shukla and Swalaha Sadaf Siddiqui and Tarun Kant Tripathi and Sushil Kumar Sharma},
  journal = {Cureus},
  year = {2026},
  month = oct,
  doi = {10.7759/cureus.118541},
  url = {https://europepmc.org/article/PMC/PMC13793822},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Diagnostic Accuracy of Fine-Needle Aspiration Cytology Alone and With Cell Block Preparation for Palpable Breast Lesions: A Prospective Study in Central India
AU  - Khushboo Shukla
AU  - Swalaha Sadaf Siddiqui
AU  - Tarun Kant Tripathi
AU  - Sushil Kumar Sharma
PY  - 2026
DA  - 2026/10/24
JO  - Cureus
DO  - 10.7759/cureus.118541
UR  - https://europepmc.org/article/PMC/PMC13793822
AB  - Background Fine-needle aspiration cytology (FNAC) is a rapid and minimally invasive test for palpable breast lesions, but limited architecture and sampling variability can reduce sensitivity. Cell block preparation may complement smears by preserving tissue fragments in paraffin sections. This study estimated the diagnostic accuracy of FNAC and the incremental diagnostic yield obtained by adding cell block interpretation in the histologically verified subset, while describing cell block adequacy in the entire enrolled cohort. Materials and methods This prospective observational diagnostic accuracy study enrolled 74 consecutive patients with palpable breast lesions at a tertiary-care center in Bhopal, India, from May 2024 through December 2025. A first dedicated pass was used for conventional smears and a second for plasma-thrombin cell block preparation. FNAC was classified using the International Academy of Cytology Yokohama system. Histopathology was available for 46 clinically biopsied or excised lesions and served as the reference standard. Exact 95% confidence intervals were calculated from the two-by-two counts, and FNAC and combined interpretation were compared using an exact two-sided McNemar test among the 46 verified participants. Results The mean age was 36.4 ± 14.0 years, and 70 participants (94.6%) were female. All FNAC smears were adequate; 58 lesions (78.4%) were benign, 1 (1.4%) atypical, 5 (6.8%) suspicious, and 10 (13.5%) malignant. Ten cell blocks (13.5%) were inadequate or hemorrhagic. Histopathology identified 35 benign and 11 malignant lesions. FNAC yielded 81.82% sensitivity (95% CI, 48.22%-97.72%), 100% specificity (95% CI, 90.00%-100%), and 95.65% accuracy (95% CI, 85.16%-99.47%). Combined interpretation yielded 90.91% sensitivity (95% CI, 58.72%-99.77%), 100% specificity (95% CI, 90.00%-100%), and 97.83% accuracy (95% CI, 88.47%-99.94%). Paired analysis showed one discordant result favoring combined interpretation and none favoring FNAC (exact McNemar p = 1.000). Conclusions Combined interpretation showed numerically higher sensitivity and accuracy than FNAC alone in the histologically verified subset, but the small number of malignant lesions, wide confidence intervals, and partial verification preclude a definitive claim of superiority. Cell blocks are best used as an adjunct within clinical-radiological-pathological correlation; discordant or concerning lesions still require histopathology.
SN  - 2168-8184
ER  -