Sternal retraction-induced internal mammary artery graft flow impairment: intraoperative assessment and mechanistic insights: a case report.
- 1Department of Cardiovascular and Thoracic Surgery, Gifu Prefectural General Medical Center, Noishiki 4-6-1, Gifu, 500-8717, Japan.
- 2Transplantation Research Center, Brigham and Women's Hospital, Harvard Medical School, 221 Longwood Ave, Boston, MA 02115, USA.
- 3Department of Cardiovascular Surgery, Gifu University Graduate School of Medicine, Yanagido 1-1, Gifu, 501-1194, Japan.
Abstract
Background
The internal mammary artery (IMA) is the primary conduit for coronary revascularization, making reliable intraoperative flow assessment indispensable. We describe a rare case in which left IMA (LIMA) graft flow was compromised not by conduit or anastomotic issues but by sternal manipulation.Case summary
A 76-year-old man undergoing emergency coronary artery bypass surgery reproducibly demonstrated markedly reduced LIMA flow only during wide sternal retraction. Intraoperatively, pronounced unilateral sternal retraction was noted, and postoperative computed tomography confirmed first- and second-rib fractures.Discussion
These findings suggest a dynamic, retraction-dependent inflow disturbance, possibly related to deformation of the thoracic outlet and proximal subclavian artery. This case underscores the need for careful sternal manipulation, which may help avoid unnecessary graft revision or conduit replacement.
Related
- Irreversible Primary Visual Cortex Impairment in a Mouse Model of High-Risk Schizophrenia [Retraction].
- Evaluating a 6.0-mm candidate warning level for intraoperative L5 nerve root retraction distance during posterior lumbar interbody fusion: a retrospective cohort study
- Interpretable machine learning for predicting intraoperative oxygenation impairment during one-lung ventilation in thoracic surgery: a retrospective cohort study
- Intraoperative hypotension and postoperative neurocognitive impairment in surgical patients with sepsis: A retrospective observational study
- Intraoperative specimen ultrasonography for margin assessment in breast conserving surgery in comparison with specimen mammography
BibTeX
@article{umeda2026sternal,
title = {{Sternal retraction-induced internal mammary artery graft flow impairment: intraoperative assessment and mechanistic insights: a case report.}},
author = {Yukio Umeda and Yuta Inoue and Shohei Mitta and Yukihiro Matsuno and Kenichiro Azuma},
journal = {European heart journal. Case reports},
year = {2026},
month = nov,
doi = {10.1093/ehjcr/ytag812},
url = {https://europepmc.org/article/MED/43011559},
note = {CC BY},
}
RIS
TY - JOUR
TI - Sternal retraction-induced internal mammary artery graft flow impairment: intraoperative assessment and mechanistic insights: a case report.
AU - Yukio Umeda
AU - Yuta Inoue
AU - Shohei Mitta
AU - Yukihiro Matsuno
AU - Kenichiro Azuma
PY - 2026
DA - 2026/11/10
JO - European heart journal. Case reports
DO - 10.1093/ehjcr/ytag812
UR - https://europepmc.org/article/MED/43011559
AB - Background The internal mammary artery (IMA) is the primary conduit for coronary revascularization, making reliable intraoperative flow assessment indispensable. We describe a rare case in which left IMA (LIMA) graft flow was compromised not by conduit or anastomotic issues but by sternal manipulation.Case summary A 76-year-old man undergoing emergency coronary artery bypass surgery reproducibly demonstrated markedly reduced LIMA flow only during wide sternal retraction. Intraoperatively, pronounced unilateral sternal retraction was noted, and postoperative computed tomography confirmed first- and second-rib fractures.Discussion These findings suggest a dynamic, retraction-dependent inflow disturbance, possibly related to deformation of the thoracic outlet and proximal subclavian artery. This case underscores the need for careful sternal manipulation, which may help avoid unnecessary graft revision or conduit replacement.
SN - 2514-2119
ER -