Translation and cultural adaptation of the Oxford Shoulder Score to Swedish and validation of a new 7-day recall version in patients with a proximal humerus fracture
4 affiliations
- 1Department of Orthopaedic Surgery, Linköping University Hospital, Linköping
- 2Department of Biomedical and Clinical Sciences, Linköping University
- 3Department of Physiotherapy, School of Medical Sciences, Faculty of Medicine and Health, Örebro University
- 4Department of Orthopaedic Surgery, Örebro University, Örebro, Sweden
Abstract
Background and purpose: The Oxford Shoulder Score (OSS) is a widely applied patient-reported outcome measure (PROM) designed to assess function and pain in individuals with shoulder disorders. We primarily aimed to evaluate a translated and culturally adapted Swedish version of the original OSS and secondarily to evaluate a version with a 7-day recall period, intended for rapidly changing conditions such as the early phase following fractures and surgeries.
Methods: The OSS was translated according to Beaton’s guidelines for cross-cultural adaptation. 246 patients with a nonoperatively treated proximal humerus fracture completed the Swedish OSS and the QuickDASH at 1 week (T1, 7-day recall period), 3 months (T2, 7-day recall period), and 12 months (T3, 4-week recall period).
Results: Convergent validity between OSS and QuickDASH (Spearmans’s rho) was rs −0.75 (95% confidence interval [CI] –0.80 to –0.68) at T1, –0.88 (CI –0.91 to –0.84) at T2, and –0.86 (CI –0.90 to –0.81) at T3. Responsiveness for change scores (T2–T1) was –0.77 (CI –0.82 to –0.70) and (T3–T2) –0.80 (CI –0.85 to –0.74). Internal consistency for the respective domains was for pain at T1 0.73 (CI 0.68–0.78), at T2 0.84 (CI 0.80–0.87), at T3 0.87 (CI 0.84–0.89), and for function at T1 0.74 (CI 0.68–0.78), at T2 0.88 (CI 0.86–0.90), at T3 0.91 (CI 0.89–0.92). Intra-rater reliability was ICC = 0.94 (CI 0.90–0.96) between T3 and 2 weeks later.
Conclusion: The Swedish translation of the OSS demonstrated excellent measurement properties. The 7-day recall version demonstrated equivalent good validity, responsiveness, and reliability and seems valuable for monitoring fresh injuries such as proximal humerus fractures.
Related
- Turkish translation, cultural adaptation, and validation of the patient-reported Villalta scale for the diagnosis of postthrombotic syndrome in patients with vascular Behçet disease
- Cross-cultural adaptation, validation, and arabic translation of the rhinoplasty outcome evaluation
- Persian version of the international consultation on incontinence questionnaire-pediatric lower urinary tract symptoms caregiver module: translation, validation and cultural adaptation.
- Translation, Cultural Adaptation, and Validation of the Turkish Version of the St George's Respiratory Questionnaire for Idiopathic Pulmonary Fibrosis (SGRQ-I).
- Translation, Cultural Adaptation, and Preliminary Validation of the Persian Version of the Assessment of Medical Education Environment by Teachers (AMEET) Questionnaire
BibTeX
@article{lundin2026translation,
title = {{Translation and cultural adaptation of the Oxford Shoulder Score to Swedish and validation of a new 7-day recall version in patients with a proximal humerus fracture}},
author = {Per C LUNDIN and Therése F D SUNDH and Lars E ADOLFSSON and Hanna C BJÖRNSSON HALLGREN},
journal = {Acta Orthopaedica},
year = {2026},
month = nov,
doi = {10.2340/17453674.2026.46975},
url = {https://doi.org/10.2340/17453674.2026.46975},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Translation and cultural adaptation of the Oxford Shoulder Score to Swedish and validation of a new 7-day recall version in patients with a proximal humerus fracture
AU - Per C LUNDIN
AU - Therése F D SUNDH
AU - Lars E ADOLFSSON
AU - Hanna C BJÖRNSSON HALLGREN
PY - 2026
DA - 2026/11/12
JO - Acta Orthopaedica
DO - 10.2340/17453674.2026.46975
UR - https://doi.org/10.2340/17453674.2026.46975
AB - Background and purpose: The Oxford Shoulder Score (OSS) is a widely applied patient-reported outcome measure (PROM) designed to assess function and pain in individuals with shoulder disorders. We primarily aimed to evaluate a translated and culturally adapted Swedish version of the original OSS and secondarily to evaluate a version with a 7-day recall period, intended for rapidly changing conditions such as the early phase following fractures and surgeries. Methods: The OSS was translated according to Beaton’s guidelines for cross-cultural adaptation. 246 patients with a nonoperatively treated proximal humerus fracture completed the Swedish OSS and the QuickDASH at 1 week (T1, 7-day recall period), 3 months (T2, 7-day recall period), and 12 months (T3, 4-week recall period). Results: Convergent validity between OSS and QuickDASH (Spearmans’s rho) was rs −0.75 (95% confidence interval [CI] –0.80 to –0.68) at T1, –0.88 (CI –0.91 to –0.84) at T2, and –0.86 (CI –0.90 to –0.81) at T3. Responsiveness for change scores (T2–T1) was –0.77 (CI –0.82 to –0.70) and (T3–T2) –0.80 (CI –0.85 to –0.74). Internal consistency for the respective domains was for pain at T1 0.73 (CI 0.68–0.78), at T2 0.84 (CI 0.80–0.87), at T3 0.87 (CI 0.84–0.89), and for function at T1 0.74 (CI 0.68–0.78), at T2 0.88 (CI 0.86–0.90), at T3 0.91 (CI 0.89–0.92). Intra-rater reliability was ICC = 0.94 (CI 0.90–0.96) between T3 and 2 weeks later. Conclusion: The Swedish translation of the OSS demonstrated excellent measurement properties. The 7-day recall version demonstrated equivalent good validity, responsiveness, and reliability and seems valuable for monitoring fresh injuries such as proximal humerus fractures.
SN - 1745-3674
SN - 1745-3682
ER -