rhythmCI: an R package for rhythm detection using harmonic regression amplitude confidence intervals
- 1Charite Universitaetsmedizin Berlin
Abstract
Circadian clocks are evolutionarily conserved systems that orchestrate daily rhythms in human physiology, tissue behavior, and cellular function. In circadian research, the NanoString nCounter platform has emerged as a robust alternative to microarray and RNA sequencing. However, raw instrument output requires specialized preprocessing to handle technical noise. Furthermore, while harmonic regression is widely used to detect periodic signals in biological time-series data, evaluating rhythmicity remains highly challenging in clinical studies characterized by sparse sampling and small sample sizes. To address these limitations, we developed rhythmCI, an easy-to-use R package that integrates established normalization methods with a complete workflow for circadian data analysis. The package incorporates a bootstrapping procedure to estimate confidence intervals for harmonic regression amplitudes, offering a statistically transparent way to quantify rhythmicity in small-cohort studies. rhythmCI provides an end-to-end workflow for NanoString nCounter data, including automated preprocessing, normalization, and visualization. We evaluated the utility and accuracy of the package using synthetic time-series data generated with the Simphony framework, demonstrating that rhythmCI produces interpretable and reliable rhythmicity classifications under controlled simulation conditions. rhythmCI bridges a critical gap in circadian bioinformatics by offering a reliable method to characterize periodicity under challenging experimental designs typical of clinical research. By streamlining NanoString workflows and improving the statistical rigor of rhythm detection in small datasets, rhythmCI enhances the accessibility and reliability of circadian biology analysis.
Related
- Supramodal Coding of Detection and Confidence in the Human Cortex
- Transformer-aided guard: A hybrid spatio-temporal framework for confidence-aware intrusion detection in cyber-physical systems
- RKMR: A Rapid Kernel Machine Regression Framework for Optimal Marker Detection in Spatial Omics Data
- Reproductive Efficiency: The Economics of Calving Intervals and Distributions
- Amplitude without phase: interpersonal movement coordination grades inter-brain coupling
BibTeX
@misc{sreekanth2026rhythmci,
title = {{rhythmCI: an R package for rhythm detection using harmonic regression amplitude confidence intervals}},
author = {J. Sreekanth and A. Edel and C. Spies and S. Andreotti and B. Ananthasubramaniam},
howpublished = {bioRxiv},
year = {2026},
month = oct,
doi = {10.64898/2026.10.05.756647},
url = {https://www.biorxiv.org/content/10.64898/2026.10.05.756647v1},
note = {CC BY-NC-ND},
}
RIS
TY - UNPB
TI - rhythmCI: an R package for rhythm detection using harmonic regression amplitude confidence intervals
AU - J. Sreekanth
AU - A. Edel
AU - C. Spies
AU - S. Andreotti
AU - B. Ananthasubramaniam
PY - 2026
DA - 2026/10/05
PB - bioRxiv
DO - 10.64898/2026.10.05.756647
UR - https://www.biorxiv.org/content/10.64898/2026.10.05.756647v1
AB - Circadian clocks are evolutionarily conserved systems that orchestrate daily rhythms in human physiology, tissue behavior, and cellular function. In circadian research, the NanoString nCounter platform has emerged as a robust alternative to microarray and RNA sequencing. However, raw instrument output requires specialized preprocessing to handle technical noise. Furthermore, while harmonic regression is widely used to detect periodic signals in biological time-series data, evaluating rhythmicity remains highly challenging in clinical studies characterized by sparse sampling and small sample sizes. To address these limitations, we developed rhythmCI, an easy-to-use R package that integrates established normalization methods with a complete workflow for circadian data analysis. The package incorporates a bootstrapping procedure to estimate confidence intervals for harmonic regression amplitudes, offering a statistically transparent way to quantify rhythmicity in small-cohort studies. rhythmCI provides an end-to-end workflow for NanoString nCounter data, including automated preprocessing, normalization, and visualization. We evaluated the utility and accuracy of the package using synthetic time-series data generated with the Simphony framework, demonstrating that rhythmCI produces interpretable and reliable rhythmicity classifications under controlled simulation conditions. rhythmCI bridges a critical gap in circadian bioinformatics by offering a reliable method to characterize periodicity under challenging experimental designs typical of clinical research. By streamlining NanoString workflows and improving the statistical rigor of rhythm detection in small datasets, rhythmCI enhances the accessibility and reliability of circadian biology analysis.
ER -