Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 19 min ago
Peer-reviewedCC BYFrontiers in medicine

Development and internal validation of an objective diagnostic model based on gastric filling ultrasonography for gastric stump carcinoma: a TRIPOD-compliant retrospective study.

  1. 1Department of Ultrasound, Sichuan Provincial People's Hospital, School of Medicine, University of Electronic Science and Technology of China, Chengdu, China.

Abstract

Background

Gastric stump carcinoma (GSC) is a late complication of partial gastrectomy. Gastroscopy (GS) is invasive and poorly tolerated. Gastric filling ultrasonography (GFU) is non-invasive, yet its interpretation has been largely subjective. This study aimed to develop and internally validate an objective GFU-based diagnostic model for GSC.Methods

In this single-center retrospective study, 93 patients who underwent partial gastrectomy and received both GS and GFU (March 2008-June 2024) were included (60 GSC, 33 benign; all pathologically confirmed). Ten GFU indicators were evaluated. Univariate logistic regression screened predictors; a final two-predictor model was fitted using Firth penalized logistic regression. Performance was assessed by AUC, bootstrap internal validation (1,000 resamples), cross-validation, calibration, decision curve analysis, and DeLong tests.Results

Thickest lesion diameter and absence of submucosal echo interruption were retained. The Firth model was: logit(P) = -1.456 + 3.131 × (thickest diameter, cm)-2.287 × (submucosal echo interruption absent; absent=1, present=0). Apparent AUC was 0.917 (95% CI 0.862-0.973); optimism-corrected AUC was 0.886 (95% CI 0.822-0.946). Calibration was satisfactory (Hosmer-Lemeshow p = 0.694; bootstrap-corrected slope 0.87). At the cut-off of 0.655, sensitivity was 86.7% and specificity 81.8%. The model significantly outperformed subjective GFU (ΔAUC = 0.075, p = 0.019) but not subjective GS (ΔAUC = 0.024, p = 0.574).Conclusions

An objective two-parameter GFU model showed good, internally validated discrimination for GSC and outperformed subjective GFU. It may serve as a complementary triage tool alongside GS in postgastrectomy surveillance. External validation is required before clinical implementation.

Related

  1. Development and validation of a parsimonious clinical-texture signature for differentiating primary lung cancer from pulmonary metastases on ¹⁸F-FDG PET/CT: a retrospective diagnostic study
    Sara Momeni, Mahsa Mansourian
    BMC Medical ImagingPeer-reviewedCC BY-NC-ND 4.0Full textMedical imaging & radiologyPMC
  2. Development and validation of a clinical prediction model for diagnosing nephrotic syndrome in adults: a retrospective diagnostic prediction study
    Xiaoyang Dong, Jing Nie, Yi Yan
    Frontiers in MedicinePeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  3. Development and validation of a LightGBM-based diagnostic model for acute-on-chronic liver failure in patients with liver cirrhosis: a multicenter retrospective study in an HBV-predominant cohort.
    Manni Xiao, Xiao Zhang, Juntao Tan +5
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  4. Development and validation of a fall risk prediction model integrating objective gait metrics for patients with cerebral small vessel disease: protocol for a two-phase study
    Yue Cheng, Qianbei Wang, Xihua Wang +4
    BMJ OpenPeer-reviewedCC BY-NC 4.0Full textGeneral medicineCrossrefEurope PMC
  5. Development and internal validation of a nomogram for predicting flexible bronchoscopy utilization in children with lobar pneumonia caused by Mycoplasma pneumoniae: a single-center retrospective cohort study
    Translational pediatricsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{wei2026development,
  title = {{Development and internal validation of an objective diagnostic model based on gastric filling ultrasonography for gastric stump carcinoma: a TRIPOD-compliant retrospective study.}},
  author = {Qiuxin Wei and Hui Zhang},
  journal = {Frontiers in medicine},
  year = {2026},
  month = nov,
  doi = {10.3389/fmed.2026.2010801},
  url = {https://europepmc.org/article/MED/43080294},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Development and internal validation of an objective diagnostic model based on gastric filling ultrasonography for gastric stump carcinoma: a TRIPOD-compliant retrospective study.
AU  - Qiuxin Wei
AU  - Hui Zhang
PY  - 2026
DA  - 2026/11/10
JO  - Frontiers in medicine
DO  - 10.3389/fmed.2026.2010801
UR  - https://europepmc.org/article/MED/43080294
AB  - Background  Gastric stump carcinoma (GSC) is a late complication of partial gastrectomy. Gastroscopy (GS) is invasive and poorly tolerated. Gastric filling ultrasonography (GFU) is non-invasive, yet its interpretation has been largely subjective. This study aimed to develop and internally validate an objective GFU-based diagnostic model for GSC.Methods  In this single-center retrospective study, 93 patients who underwent partial gastrectomy and received both GS and GFU (March 2008-June 2024) were included (60 GSC, 33 benign; all pathologically confirmed). Ten GFU indicators were evaluated. Univariate logistic regression screened predictors; a final two-predictor model was fitted using Firth penalized logistic regression. Performance was assessed by AUC, bootstrap internal validation (1,000 resamples), cross-validation, calibration, decision curve analysis, and DeLong tests.Results  Thickest lesion diameter and absence of submucosal echo interruption were retained. The Firth model was: logit(P) = -1.456 + 3.131 × (thickest diameter, cm)-2.287 × (submucosal echo interruption absent; absent=1, present=0). Apparent AUC was 0.917 (95% CI 0.862-0.973); optimism-corrected AUC was 0.886 (95% CI 0.822-0.946). Calibration was satisfactory (Hosmer-Lemeshow p = 0.694; bootstrap-corrected slope 0.87). At the cut-off of 0.655, sensitivity was 86.7% and specificity 81.8%. The model significantly outperformed subjective GFU (ΔAUC = 0.075, p = 0.019) but not subjective GS (ΔAUC = 0.024, p = 0.574).Conclusions  An objective two-parameter GFU model showed good, internally validated discrimination for GSC and outperformed subjective GFU. It may serve as a complementary triage tool alongside GS in postgastrectomy surveillance. External validation is required before clinical implementation.
SN  - 2296-858X
ER  -