Skip to content
DraconiticResearch
Search Sources API
190,839 studies31 sourcesUpdated just now
Peer-reviewedCC BYJournal of healthcare informatics research

The Impact of Bias Mitigation on Fairness and Accuracy in Automated Skin Lesion Classification

  1. 1Labcin - Nature-inspired Computing Lab, Federal University of Espirito Santo, Vitoria, 29075-910 Brazil
  2. 2Graduate Program in Computer Science, Federal University of Espirito Santo, Vitoria, 29075-910 Brazil

Abstract

To the best of our knowledge, existing benchmarks for bias mitigation in skin cancer classification focus exclusively on image-based, leaving a gap in the tabular-multimodal setting, where image-derived probabilities are combined with structured clinical data. To address this gap, this paper proposes an experimental framework to benchmark and integrate multiple bias mitigation algorithms into automated skin cancer classification pipelines based on a Mixed Fusion architecture. Using a multimodal fusion architecture originally developed for interpretability, we extend the framework to assess diagnostic bias across image data and metadata. Experiments were conducted on three datasets: PAD-UFES-20, HIBA, and MIDAS, incorporating sensitive demographic attributes to enable a fairness evaluation. Bias mitigation techniques were systematically applied at the pre-processing, in-processing, and post-processing stages, as well as in combination, using Multi-layer Perceptron (MLP), K-Nearest Neighbors (KNN), and Decision Tree (DT) classifiers. Performance and fairness were jointly analyzed using multiple metrics. According to the A-TOPSIS ranking, the MLP achieved the best results on DB-PAD-UFES-20, with a Balanced Accuracy (BACC) of 0.8313 and Statistical Parity (SP) of 0.0050 for gender and 0.0580 for Fitzpatrick skin type. On DB-HIBA, KNN ranked first, reaching a BACC of 0.7922 and SP of 0.0047 for gender. For DB-MIDAS, MLP again performed best, achieving a BACC of 0.6911 and SP of 0.0096 for gender. Post-processing methods consistently demonstrated effectiveness across datasets. By providing a methodological foundation with baseline results, this work paves the way for future research to develop more reliable clinical diagnosis that incorporate other bias mitigation techniques.

Related

  1. Accuracy and fairness of facial recognition technology in real-world, low-quality police images: An experiment
    Maria Cuellar, Hon Kiu James To, Arush Mehrotra
    PLOS OnePeer-reviewedCC BYFull textNeurosciencePhysiologyPLOSEurope PMC
  2. Feasibility and placement accuracy of a sensor-guided intraosseous device with an automated stop in a small-bone rat cadaver model: a single-arm pilot study
    Markus Ortner, Clemens Hacker, Alexandra Kaider +5
    Resuscitation plusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Tail-Risk-Aware Model Predictive Control for Hypoglycemia Mitigation in Automated Insulin Delivery
    Kaiyuan Zhang, Congyu Han, Hexing Guo +5
    MetabolitesPeer-reviewedCC BY 4.0Full textEndocrinology & metabolismCrossrefEurope PMC
  4. Accuracy Evaluation of the Omron HEM‐7120 Automated Oscillometric Upper‐arm Home Blood Pressure Monitor in Children and Adolescents Using the AAMI/ESH/ISO 81060–2:2018 Numerical Criteria
    Tipanan Pisithkul, Kwanchai Pirojsakul
    The Journal of Clinical HypertensionPeer-reviewedCC BY-NC-ND 4.0Full textCardiovascular medicinePMCDOAJ
  5. Curriculum-Based Deep Learning for Automated Segmental Left Ventricular Hypertrophy Classification Using Short-Axis Echocardiography
    Rajeswari Periyasamy, Srinivasan Selvaraj, Francis Antony Selvi Pitchaimuthu +1
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{rocha2026impact,
  title = {{The Impact of Bias Mitigation on Fairness and Accuracy in Automated Skin Lesion Classification}},
  author = {Matheus B. Rocha and Renato A. Krohling},
  journal = {Journal of healthcare informatics research},
  year = {2026},
  month = sep,
  doi = {10.1007/s41666-026-00252-w},
  url = {https://europepmc.org/article/PMC/PMC13719965},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - The Impact of Bias Mitigation on Fairness and Accuracy in Automated Skin Lesion Classification
AU  - Matheus B. Rocha
AU  - Renato A. Krohling
PY  - 2026
DA  - 2026/09/26
JO  - Journal of healthcare informatics research
DO  - 10.1007/s41666-026-00252-w
UR  - https://europepmc.org/article/PMC/PMC13719965
AB  - To the best of our knowledge, existing benchmarks for bias mitigation in skin cancer classification focus exclusively on image-based, leaving a gap in the tabular-multimodal setting, where image-derived probabilities are combined with structured clinical data. To address this gap, this paper proposes an experimental framework to benchmark and integrate multiple bias mitigation algorithms into automated skin cancer classification pipelines based on a Mixed Fusion architecture. Using a multimodal fusion architecture originally developed for interpretability, we extend the framework to assess diagnostic bias across image data and metadata. Experiments were conducted on three datasets: PAD-UFES-20, HIBA, and MIDAS, incorporating sensitive demographic attributes to enable a fairness evaluation. Bias mitigation techniques were systematically applied at the pre-processing, in-processing, and post-processing stages, as well as in combination, using Multi-layer Perceptron (MLP), K-Nearest Neighbors (KNN), and Decision Tree (DT) classifiers. Performance and fairness were jointly analyzed using multiple metrics. According to the A-TOPSIS ranking, the MLP achieved the best results on DB-PAD-UFES-20, with a Balanced Accuracy (BACC) of 0.8313 and Statistical Parity (SP) of 0.0050 for gender and 0.0580 for Fitzpatrick skin type. On DB-HIBA, KNN ranked first, reaching a BACC of 0.7922 and SP of 0.0047 for gender. For DB-MIDAS, MLP again performed best, achieving a BACC of 0.6911 and SP of 0.0096 for gender. Post-processing methods consistently demonstrated effectiveness across datasets. By providing a methodological foundation with baseline results, this work paves the way for future research to develop more reliable clinical diagnosis that incorporate other bias mitigation techniques.
SN  - 2509-4971
SN  - 2509-498X
ER  -