Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma
- 1Department of Ophthalmology, Faculty of Medicine, Universiti Kebangsaan Malaysia, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia; (M.H.B.); (T.C.C.)
- 2Department of Ophthalmology, Hospital Canselor Tuanku Muhriz, Jalan Yaakob Latiff, Bandar Tun Razak, Cheras, Kuala Lumpur 56000, Malaysia
Abstract
Objectives: We aimed to evaluate the agreement, test–retest reliability, test duration, and patient acceptability of Melbourne Rapid Fields (MRF) tablet perimetry compared with Humphrey Field Analyzer (HFA) 24-2 SITA-Standard perimetry in glaucoma patients. Methods: This cross-sectional study evaluated 64 eyes of 64 patients with primary or secondary glaucoma. Participants underwent both HFA and MRF perimetry in a non-randomized sequence. Agreement was analyzed using intraclass correlation coefficients (ICC) and Bland–Altman analysis. Test–retest reliability of MRF was evaluated in 47 participants after 4 weeks. Acceptability was assessed via questionnaires. Results: MRF demonstrated comparable reliability indices to HFA (p > 0.05), although these findings do not establish equivalent clinical reliability due to differences in platform-specific definitions. MRF demonstrated excellent test–retest reliability for MD (ICC 0.993), PD (ICC 0.992), and VC (ICC 0.992; all p < 0.001). Compared with HFA, MRF produced significantly less negative MD (−6.27 ± 5.55 vs. −8.32 ± 5.47 dB, p < 0.001) and higher PSD/PD (7.48 ± 3.26 vs. 6.33 ± 4.11 dB, p < 0.001), while VFI/VC did not differ significantly (p = 0.808). Overall agreement was good-to-excellent MD (ICC 0.949), PSD/PD (ICC 0.880), and VFI/VC (ICC 0.930). However, exploratory severity-stratified Bland–Altman analysis suggested greater variability in moderate and severe glaucoma. MRF was significantly faster than HFA (4.22 ± 0.81 vs. 5.46 ± 1.33 min, p < 0.001). All patients reported it was easy and comfortable. Conclusions: MRF provides excellent test–retest reliability, shorter testing duration, and high patient acceptability. While overall agreement is high, systematic differences and greater advanced-stage variability prevent direct interchangeability with HFA. Instead, MRF serves as a practical, complementary platform for accessible, frequent testing.
Related
- Remote Assessment of Mobility in People with Parkinson's Disease: A Feasibility, Safety, Validity, Agreement, and Reliability Study
- Feasibility and performance of eye movement perimetry for glaucoma triage in Tanzania: A prospective cross-sectional study in a real-world setting
- AI‐Based Wound Measurement in a Telemedicine‐Style Workflow: Agreement With In‐Person Reference Measurements Compared With Individual Physicians and Expert Consensus
- Large language models for systematic review tasks compared with Cochrane reviews: a protocol for evaluating accuracy, agreement, and time efficiency.
- The reliability conundrum of DWI-ASPECTS in stroke assessment: a systematic review of agreement on DWI-ASPECTS in anterior circulation stroke
BibTeX
@article{basri2026agreement,
title = {{Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma}},
author = {Murshidah Hassan Basri and Teck Chee Cheng and Rona Asnida Nasaruddin and Jemaima Che Hamzah},
journal = {Diagnostics},
year = {2026},
month = oct,
doi = {10.3390/diagnostics16213528},
url = {https://doi.org/10.3390/diagnostics16213528},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Agreement, Reliability, and Feasibility of Melbourne Rapid Fields Tablet Perimetry Compared with Humphrey Field Analyzer in Glaucoma
AU - Murshidah Hassan Basri
AU - Teck Chee Cheng
AU - Rona Asnida Nasaruddin
AU - Jemaima Che Hamzah
PY - 2026
DA - 2026/10/27
JO - Diagnostics
DO - 10.3390/diagnostics16213528
UR - https://doi.org/10.3390/diagnostics16213528
AB - Objectives: We aimed to evaluate the agreement, test–retest reliability, test duration, and patient acceptability of Melbourne Rapid Fields (MRF) tablet perimetry compared with Humphrey Field Analyzer (HFA) 24-2 SITA-Standard perimetry in glaucoma patients. Methods: This cross-sectional study evaluated 64 eyes of 64 patients with primary or secondary glaucoma. Participants underwent both HFA and MRF perimetry in a non-randomized sequence. Agreement was analyzed using intraclass correlation coefficients (ICC) and Bland–Altman analysis. Test–retest reliability of MRF was evaluated in 47 participants after 4 weeks. Acceptability was assessed via questionnaires. Results: MRF demonstrated comparable reliability indices to HFA (p > 0.05), although these findings do not establish equivalent clinical reliability due to differences in platform-specific definitions. MRF demonstrated excellent test–retest reliability for MD (ICC 0.993), PD (ICC 0.992), and VC (ICC 0.992; all p < 0.001). Compared with HFA, MRF produced significantly less negative MD (−6.27 ± 5.55 vs. −8.32 ± 5.47 dB, p < 0.001) and higher PSD/PD (7.48 ± 3.26 vs. 6.33 ± 4.11 dB, p < 0.001), while VFI/VC did not differ significantly (p = 0.808). Overall agreement was good-to-excellent MD (ICC 0.949), PSD/PD (ICC 0.880), and VFI/VC (ICC 0.930). However, exploratory severity-stratified Bland–Altman analysis suggested greater variability in moderate and severe glaucoma. MRF was significantly faster than HFA (4.22 ± 0.81 vs. 5.46 ± 1.33 min, p < 0.001). All patients reported it was easy and comfortable. Conclusions: MRF provides excellent test–retest reliability, shorter testing duration, and high patient acceptability. While overall agreement is high, systematic differences and greater advanced-stage variability prevent direct interchangeability with HFA. Instead, MRF serves as a practical, complementary platform for accessible, frequent testing.
SN - 2075-4418
ER -