Peer-reviewedCC BY-NC-ND 4.0Investigative Ophthalmology & Visual Science

The Relationship Between Interocular Lag and Contrast Sensitivity in Amblyopia

  1. 1Department of Ophthalmology, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
  2. 2Laboratory of Optometry and Vision Sciences, West China Hospital, Sichuan University, Chengdu, Sichuan, People's Republic of China
  3. 3McGill Vision Research Unit, Department of Ophthalmology and Visual Sciences, McGill University, Montreal, Quebec, Canada

Abstract

Purpose: Previous studies have reported a processing time difference between the two eyes in unilateral amblyopia. In the current study, we measured the interocular lag (IOLag) and contrast sensitivity across different spatial frequencies (SFs) to investigate (1) whether the interocular lag varies as a function of SF and (2) whether the temporal binocular imbalance depends on contrast sensitivity.

Methods: Twenty adult participants with amblyopia and 20 healthy controls participated in this experiment. We measured the IOLag by using a continuous tracking task. One white-noise condition and 5 different SFs: 0.5, 1, 2, 4, and 8 c/deg were tested. The contrast sensitivity function (CSF) was assessed using the quick contrast sensitivity function (qCSF) procedure.

Results: In healthy controls, we observed IOLags close to 0 at all SFs. Amblyopic individuals exhibited a significant IOLag across all SFs compared with controls (F1,38 = 13.8, P = 0.001), with a mean value of 35.2 ms. In addition, we found that the mean IOLag in amblyopia was positively correlated with the area under the log CSF ratio (AULCSF; rho = 0.611, P = 0.004) and that the absolute IOLag was correlated with interocular visual acuity (VA) difference (rho = 0.614, P = 0.004).

Conclusions: We demonstrated that the IOLag depends on SF in amblyopia. In addition, we found that this temporal imbalance of amblyopia was linked with their spatial imbalance. This temporal asynchrony in amblyopia should not be ignored in amblyopic visual deficits and vision rebuilding.

Related

  1. Intrinsic Organization of Contrast Sensitivity in Human Vision
    S. Gepshtein, S. Savel'ev, A. A. Minns +1
    bioRxivPreprintCC BYFull textNeurosciencebioRxiv
  2. Macular Pigment Optical Density Is Not Associated with Contrast Sensitivity When Measured with 520 nm Monochromatic Stimuli.
    Jeffrey Nightingale, Cameron Wysocky, Jacob Harth +2
    Vision (Basel, Switzerland)Peer-reviewedCC BYFull textNeuroscienceEurope PMC
  3. Higher rewards lead to more accurate flower detection and increased contrast sensitivity in the bumblebee Bombus terrestris
    T. Robert, E. Flett, H. Le Lay +2
    bioRxivPreprintCC BYFull textZoology & animal behaviourbioRxiv
  4. Theta burst stimulation of the visual cortex does not alter contrast sensitivity under optically induced blur
    Crystal Suei Cheng Wong, Ken Wei Sheng Tan, Tingni Li +4
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePhysiologyPLOS
  5. Unilateral Congenital Ptosis Is Associated With Impaired Binocular Vision and Reduced Contrast Sensitivity in Children
    Kelin Li, Zhouyue Li, Qingqing Ye +7
    Investigative Ophthalmology & Visual SciencePeer-reviewedCC BY-NC-ND 4.0Full textGenetics & genomicsPMC
BibTeX
@article{wang2026relationship,
  title = {{The Relationship Between Interocular Lag and Contrast Sensitivity in Amblyopia}},
  author = {Xi Wang and Changwu Tan and Tong Liu and Longqian Liu and Alexandre Reynaud},
  journal = {Investigative Ophthalmology \& Visual Science},
  year = {2026},
  month = oct,
  doi = {10.1167/iovs.67.12.56},
  url = {https://doi.org/10.1167/iovs.67.12.56},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - The Relationship Between Interocular Lag and Contrast Sensitivity in Amblyopia
AU  - Xi Wang
AU  - Changwu Tan
AU  - Tong Liu
AU  - Longqian Liu
AU  - Alexandre Reynaud
PY  - 2026
DA  - 2026/10/23
JO  - Investigative Ophthalmology & Visual Science
DO  - 10.1167/iovs.67.12.56
UR  - https://doi.org/10.1167/iovs.67.12.56
AB  - Purpose: Previous studies have reported a processing time difference between the two eyes in unilateral amblyopia. In the current study, we measured the interocular lag (IOLag) and contrast sensitivity across different spatial frequencies (SFs) to investigate (1) whether the interocular lag varies as a function of SF and (2) whether the temporal binocular imbalance depends on contrast sensitivity.  Methods: Twenty adult participants with amblyopia and 20 healthy controls participated in this experiment. We measured the IOLag by using a continuous tracking task. One white-noise condition and 5 different SFs: 0.5, 1, 2, 4, and 8 c/deg were tested. The contrast sensitivity function (CSF) was assessed using the quick contrast sensitivity function (qCSF) procedure.  Results: In healthy controls, we observed IOLags close to 0 at all SFs. Amblyopic individuals exhibited a significant IOLag across all SFs compared with controls (F1,38 = 13.8, P = 0.001), with a mean value of 35.2 ms. In addition, we found that the mean IOLag in amblyopia was positively correlated with the area under the log CSF ratio (AULCSF; rho = 0.611, P = 0.004) and that the absolute IOLag was correlated with interocular visual acuity (VA) difference (rho = 0.614, P = 0.004).  Conclusions: We demonstrated that the IOLag depends on SF in amblyopia. In addition, we found that this temporal imbalance of amblyopia was linked with their spatial imbalance. This temporal asynchrony in amblyopia should not be ignored in amblyopic visual deficits and vision rebuilding.
SN  - 0146-0404
SN  - 1552-5783
ER  -