Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 10 min ago
PreprintCC BY-NC-NDbioRxiv

Comparing re-referencing methods for human intracranial EEG

  1. 1University of Glasgow

Abstract

Stereo-electroencephalography (SEEG) involves the implantation of depth electrodes in the brain to monitor epileptic seizures for surgical feasibility. As the electrodes advance into deeper limbic structures, the macro contacts distributed along the shaft record electrical activity from more lateral sites, while a bundled array of microwires simultaneously captures highly localised signals from the tip of the electrode. In a clinical setting these electrical signals are recorded relative to a reference signal, which may be sub-optimal for subsequent analyses that are unrelated to clinical objectives. Therefore, a secondary re-referencing operation is often undertaken to transform the signal in relation to a specific hypothesis. Despite a recent surge in SEEG studies, comparative studies on the much-understudied issue of re-referencing are sparse. Here, we analyse data collected from 16 human patients during an episodic memory task and comparatively apply a range of re-referencing methods to both macro contact and micro-wire data. We find that the choice of method changes the proportion of trials that survive artefact rejection, low frequency power, and the aperiodic background against which that power is read. In the hippocampal recordings, however, no method differed from any other in the size of a memory effect in power or spike-field coherence. This early transformative decision therefore bears on how the signal is described. We found no evidence that it changes the detectability of the behavioural effects tested here, and no method reversed the direction of a memory effect.

Related

  1. Comparing pest survey methods through detection probability: seasonal and abundance-dependent detection of spotted lanternfly (Lycorma delicatula, Hemiptera: Fulgoridae)
    J. A. Keller, M. R. Helmus, K. Hoover
    bioRxivPreprintAll rights reservedFull textEcologybioRxiv
  2. Intracranial electrophysiology reveals distinct neural representations of nociception and salience in the human brain
    S. Joshi, M. Polat, S. Pantis +9
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  3. Comparing ARG inference methods under transmission of reproductive success: Tree imbalance matters
    Fanny Pouyet, Ferdinand Petit, Jérémy Guez +5
    Genome Biology and EvolutionPeer-reviewedCC BY-NC 4.0Full textGenetics & genomicsHAL
  4. Neural correlates of perceptual consciousness from within: a narrative review of human intracranial research
    Francois Stockart, Alexis Robin, Hal Blumenfeld +6
    eLifePeer-reviewedCC BY 4.0Full textNeuroscienceHAL
  5. Comparing Measurements of Pictorial Depth: Conditions for Placing Methods, Observers and Depiction Styles on One Scale
    Adam Y. Shavit
    arXivPreprintarXiv licenceFull textNeuroscienceStatisticsarXiv
BibTeX
@misc{kolibius2026comparing,
  title = {{Comparing re-referencing methods for human intracranial EEG}},
  author = {L. D. Kolibius and G. Parish and M. van der Plas and M. Ter Wal and D. Rollings and S. Gollwitzer and K. Walther and R. Hopfengärtner and H. Hamer and M. Wimber and S. Hanslmayr},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.13.758866},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.13.758866v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Comparing re-referencing methods for human intracranial EEG
AU  - L. D. Kolibius
AU  - G. Parish
AU  - M. van der Plas
AU  - M. Ter Wal
AU  - D. Rollings
AU  - S. Gollwitzer
AU  - K. Walther
AU  - R. Hopfengärtner
AU  - H. Hamer
AU  - M. Wimber
AU  - S. Hanslmayr
PY  - 2026
DA  - 2026/10/13
PB  - bioRxiv
DO  - 10.64898/2026.10.13.758866
UR  - https://www.biorxiv.org/content/10.64898/2026.10.13.758866v1
AB  - Stereo-electroencephalography (SEEG) involves the implantation of depth electrodes in the brain to monitor epileptic seizures for surgical feasibility. As the electrodes advance into deeper limbic structures, the macro contacts distributed along the shaft record electrical activity from more lateral sites, while a bundled array of microwires simultaneously captures highly localised signals from the tip of the electrode. In a clinical setting these electrical signals are recorded relative to a reference signal, which may be sub-optimal for subsequent analyses that are unrelated to clinical objectives. Therefore, a secondary re-referencing operation is often undertaken to transform the signal in relation to a specific hypothesis. Despite a recent surge in SEEG studies, comparative studies on the much-understudied issue of re-referencing are sparse. Here, we analyse data collected from 16 human patients during an episodic memory task and comparatively apply a range of re-referencing methods to both macro contact and micro-wire data. We find that the choice of method changes the proportion of trials that survive artefact rejection, low frequency power, and the aperiodic background against which that power is read. In the hippocampal recordings, however, no method differed from any other in the size of a memory effect in power or spike-field coherence. This early transformative decision therefore bears on how the signal is described. We found no evidence that it changes the detectability of the behavioural effects tested here, and no method reversed the direction of a memory effect.
ER  -