Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 43 min ago
PreprintarXiv licencearXiv

Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue

Abstract

Flexible neural electrode threads must be placed at a prescribed depth while the cortical surface moves with cardiac and respiratory pulsation. A controller tracking a fixed point in the laboratory frame cannot distinguish commanded insertion from tissue motion; the error appears as both a depth offset and relative tip--tissue velocity during contact. This paper formulates thread insertion in tissue-relative coordinates: a harmonic observer predicts delayed cortical-surface motion over the control horizon, a constrained MPC regulates the tip relative to that prediction while limiting actuator effort and lateral relative velocity, and an augmented disturbance state removes the steady offset from persistent contact force and model mismatch. In a 1-DOF MuJoCo benchmark, the controller reaches RMS relative-placement errors of 12.0\um\ free-space and 1.9\um\ in contact, versus 18.3/176.8\um\ for delayed-feedback impedance and 286.1/275.5\um\ for laboratory-frame PD -- the lower contact offset costs more peak contact force (3.43 vs.\ 2.00~mN), since it drives to commanded depth rather than yielding to tissue. A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50~mm/s at 2.1\um\ lateral placement error, and a feasibility-restoring soft-slack formulation keeps the shear constraint solvable under degraded sensing where a matched hard-constraint controller fails. A two-vertex Lyapunov certificate for the finite-horizon gain holds over −40%/+50% reflected-mass mismatch, and the 1-DOF QP solves in under 0.4~ms at the 95th percentile. These results are a simulation-based control benchmark, not a clinical safety claim: the modeled tip is a rigid contact point, and flexible-thread mechanics, a validated force constraint, biological damage thresholds, and hardware-realistic sensing and timing remain necessary before deployment.

Related

  1. Optimizing synthetic jet placement for control stability in increasing Reynolds number flows based on deep reinforcement learning
    Wang Jia, Hang Xu
    arXivPreprintarXiv licenceFull textFluid dynamicsarXiv
  2. Relative-Phase Control of Common-Bridge Survival in Collisions of Radially Excited Boson Stars
    Bo-Xuan Ge
    arXivPreprintarXiv licenceFull textGravitation & general relativityarXiv
  3. Capillary–gravity-wave resistance of a translating, pulsating line source
    Haim Diamant, Elie Raphaël
    Journal of Fluid MechanicsPeer-reviewedPublisher termsFull textGeneral physicsHAL
  4. Intrinsic evolution pathway connecting two quasi-steady dissipative soliton states in a pulsating Yb-doped fiber laser
    Yongpei Zhou, Xinxu Duan, Yuantong Liu +3
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  5. Nonthermal Particle Acceleration by Magnetic Pumping in Pulsating Plasmas
    Giuseppe Arrò, Vladimir Zhdankin, Fabio Bacchini
    arXivPreprintarXiv licenceFull textHigh-energy astrophysicsPlasma physicsarXiv
BibTeX
@misc{cao2026previewbased,
  title = {{Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue}},
  author = {Yongyan Cao and Xiaobo Li},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2608.08860},
  eprint = {2608.08860},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2608.08860},
}
RIS
TY  - UNPB
TI  - Preview-Based Relative-Motion Control of an Insertion Tool for Neural-Thread Placement in Pulsating Tissue
AU  - Yongyan Cao
AU  - Xiaobo Li
PY  - 2026
DA  - 2026/09/28
PB  - arXiv
DO  - 10.48550/arxiv.2608.08860
UR  - https://arxiv.org/abs/2608.08860
AB  - Flexible neural electrode threads must be placed at a prescribed depth while the cortical surface moves with cardiac and respiratory pulsation. A controller tracking a fixed point in the laboratory frame cannot distinguish commanded insertion from tissue motion; the error appears as both a depth offset and relative tip--tissue velocity during contact. This paper formulates thread insertion in tissue-relative coordinates: a harmonic observer predicts delayed cortical-surface motion over the control horizon, a constrained MPC regulates the tip relative to that prediction while limiting actuator effort and lateral relative velocity, and an augmented disturbance state removes the steady offset from persistent contact force and model mismatch. In a 1-DOF MuJoCo benchmark, the controller reaches RMS relative-placement errors of 12.0\um\ free-space and 1.9\um\ in contact, versus 18.3/176.8\um\ for delayed-feedback impedance and 286.1/275.5\um\ for laboratory-frame PD -- the lower contact offset costs more peak contact force (3.43 vs.\ 2.00~mN), since it drives to commanded depth rather than yielding to tissue. A 3-DOF extension reduces lateral shear velocity from 1.34 to 0.50~mm/s at 2.1\um\ lateral placement error, and a feasibility-restoring soft-slack formulation keeps the shear constraint solvable under degraded sensing where a matched hard-constraint controller fails. A two-vertex Lyapunov certificate for the finite-horizon gain holds over −40%/+50% reflected-mass mismatch, and the 1-DOF QP solves in under 0.4~ms at the 95th percentile. These results are a simulation-based control benchmark, not a clinical safety claim: the modeled tip is a rigid contact point, and flexible-thread mechanics, a validated force constraint, biological damage thresholds, and hardware-realistic sensing and timing remain necessary before deployment.
ER  -