Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 50 min ago
Peer-reviewedCC BY 4.0Frontiers in Public Health

Active-flow systems enhance respirator fit success in children: a comparative study with standard disposable models

  1. 1Department of Forensic Medicine, Faculty of Medicine, Chiang Mai University
  2. 2Department of Community Medicine, Faculty of Medicine, Chiang Mai University
  3. 3Environmental and Occupational Medicine Excellence Center (EnOMEC), Faculty of Medicine, Chiang Mai University

Abstract

Introduction: Children face disproportionate air pollution health risks due to their physiology and behavior. Respirator efficacy data in children remain limited. This study compared standard respirators with a modified active-flow system providing positive pressure.

Methods: Quantitative fit testing was performed on 82 children aged 5–10 years in Chiang Mai, Thailand, using the TSI Portacount Pro Plus 8,038. Success was defined by an overall mean fit factor of 100 or greater. The evaluation compared a horizontal triple-fold KN95-equivalent respirator with an active-flow model by connecting the mask to a system that provides a continuous supply of purified air from a portable HEPA-filtered unit delivering 66.5 liters per minute. Eight facial dimensions were measured via 2D photogrammetry to identify anthropometric correlations with performance. Fit testing incorporated four standardized exercises, namely bending, talking, side-to-side head turning, and up-and-down head movement, following a modified OSHA quantitative fit-testing protocol.

Results: Standard filtering facepiece respirators (FFRs) achieved a pass rate of only 3.7%. The active-flow system significantly increased the pass rate to 23.2%, with an odds ratio of 17.0, and increased the overall median fit factor from 9.5 to 39.5. Fit success was positively associated with bizygomatic breadth (aOR 1.31) and menton-sellion length (aOR 1.11), whereas a wider interpupillary distance was associated with lower odds of passing (aOR 0.67). Among the tested exercises, up-and-down head movements resulted in the lowest fit improvements. The participants reported significantly easier breathing under the active-flow condition (86.6%) than under the standard respirator (37.8%), although inconvenience was reported more frequently with the active-flow model (76.8%) than with the standard model (35.4%).

Conclusion: These findings suggest that FFRs commonly available in consumer markets may offer only limited protection for children against environmental pollutants. Active-flow systems appeared to improve both efficacy and respiratory comfort, though overall protection levels observed in this evaluation remained below thresholds generally considered protective. Given the scope of this evaluation, further research is needed to confirm these findings across broader conditions and populations, with particular attention to improving nasal seal integrity and developing portable, comfortable-to-use units with adjustable flow rates suited to real-world activity levels.

Related

  1. Observational evaluation of children’s respirator donning ability in Indonesia and Nepal
    Judith Covey, Sarah Nila, Chandika Shrestha +6
    Scientific ReportsPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  2. Urethral Stricture with a Miniaturised (22 Fr) Versus Standard (26 Fr) Resectoscope Sheath During Thulium Fibre Laser Enucleation of the Prostate: A Prospective, Two-Centre Comparative Cohort Study
    İbrahim Buldu, Mustafa Bilal Hamarat, Burak Yılmaz +2
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCCrossref
  3. Accelerated Versus Standard Ponseti Method for Idiopathic Clubfoot: A Prospective Comparative Study of Correction and Outcomes
    JM Vyshnavi, Nagakiran K Venkatakrishnaiah, Bhuvan Tej P +3
    CureusPeer-reviewedCC BYFull textObstetrics, gynaecology & paediatricsEurope PMCEurope PMCPMC
  4. Comparative efficacy and safety of de-escalation, abbreviation, and standard potent P2Y₁₂ inhibitor-based dual antiplatelet therapy strategies after acute coronary syndrome: a network meta-analysis.
    Yee-Jen Wu, Hung-Ju Lin, Yi-Chen Chou +2
    European heart journal openPeer-reviewedCC BY-NCFull textCardiovascular medicineEurope PMCPMC
  5. Comparative effectiveness of liposomal bupivacaine versus standard bupivacaine alone for brachial plexus block in upper limb surgery: A meta-analysis.
    Jianyue Wang, Yanhong Fu, Shuhui Li +1
    Saudi journal of anaesthesiaPeer-reviewedCC BY-NC-SAFull textSurgery & anaesthesiaEurope PMCPMC
BibTeX
@article{ruengdit2026activeflow,
  title = {{Active-flow systems enhance respirator fit success in children: a comparative study with standard disposable models}},
  author = {Sittiporn Ruengdit and Kampanat Wangsan and Wuttipat Kiratipaisarl and Krongporn Ongprasert},
  journal = {Frontiers in Public Health},
  year = {2026},
  month = oct,
  doi = {10.3389/fpubh.2026.1851331},
  url = {https://www.frontiersin.org/articles/10.3389/fpubh.2026.1851331/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Active-flow systems enhance respirator fit success in children: a comparative study with standard disposable models
AU  - Sittiporn Ruengdit
AU  - Kampanat Wangsan
AU  - Wuttipat Kiratipaisarl
AU  - Krongporn Ongprasert
PY  - 2026
DA  - 2026/10/14
JO  - Frontiers in Public Health
DO  - 10.3389/fpubh.2026.1851331
UR  - https://www.frontiersin.org/articles/10.3389/fpubh.2026.1851331/full
AB  - Introduction: Children face disproportionate air pollution health risks due to their physiology and behavior. Respirator efficacy data in children remain limited. This study compared standard respirators with a modified active-flow system providing positive pressure.  Methods: Quantitative fit testing was performed on 82 children aged 5–10 years in Chiang Mai, Thailand, using the TSI Portacount Pro Plus 8,038. Success was defined by an overall mean fit factor of 100 or greater. The evaluation compared a horizontal triple-fold KN95-equivalent respirator with an active-flow model by connecting the mask to a system that provides a continuous supply of purified air from a portable HEPA-filtered unit delivering 66.5 liters per minute. Eight facial dimensions were measured via 2D photogrammetry to identify anthropometric correlations with performance. Fit testing incorporated four standardized exercises, namely bending, talking, side-to-side head turning, and up-and-down head movement, following a modified OSHA quantitative fit-testing protocol.  Results: Standard filtering facepiece respirators (FFRs) achieved a pass rate of only 3.7%. The active-flow system significantly increased the pass rate to 23.2%, with an odds ratio of 17.0, and increased the overall median fit factor from 9.5 to 39.5. Fit success was positively associated with bizygomatic breadth (aOR 1.31) and menton-sellion length (aOR 1.11), whereas a wider interpupillary distance was associated with lower odds of passing (aOR 0.67). Among the tested exercises, up-and-down head movements resulted in the lowest fit improvements. The participants reported significantly easier breathing under the active-flow condition (86.6%) than under the standard respirator (37.8%), although inconvenience was reported more frequently with the active-flow model (76.8%) than with the standard model (35.4%).  Conclusion: These findings suggest that FFRs commonly available in consumer markets may offer only limited protection for children against environmental pollutants. Active-flow systems appeared to improve both efficacy and respiratory comfort, though overall protection levels observed in this evaluation remained below thresholds generally considered protective. Given the scope of this evaluation, further research is needed to confirm these findings across broader conditions and populations, with particular attention to improving nasal seal integrity and developing portable, comfortable-to-use units with adjustable flow rates suited to real-world activity levels.
SN  - 2296-2565
ER  -