Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BYProteomes

N-Dodecyl-β-D-Maltoside Replaces Polyethylene Glycol in Reducing Peptide Losses in Autosampler Vials.

  1. 1Mendel Centre for Plant Genomics and Proteomics, Central European Institute of Technology, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.
  2. 2National Centre for Biomolecular Research, Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic.

Abstract

Background: Sample loss during preparation is one of the issues in unveiling the complexity of the proteome. Here, we focused on minimizing peptide loss during their transfer and storage in autosampler vials prior to analysis. Methods: We used commercially available autosampler TPX vials and HeLa digest. Samples were acidified by formic acid, trifluoracetic acid or their combination and supplemented by polyethylene glycol (PEG, our commonly used additive), n-dodecyl-β-D-maltoside (DDM) or no additive at all. For each injection, 10 ng of peptides was administered at a volume of 10 µL; all samples were analyzed by LC-MS/MS. Results: The DDM-containing samples were able to minimize peptide losses. The addition of DDM outperformed the PEG in observed parameters such as the number of identified peptides throughout the LC gradient or the reduction in losses of high-mass peptides. DDM minimizes peptide losses in samples stored in the autosampler vials for at least seventy-two hours. Conclusions: Under the given experimental conditions, the addition of DDM is capable of replacing PEG and can be used to minimize peptide losses in autosampler vials. The use of DDM is therefore particularly advantageous for those types of samples where DDM cannot be used in the earlier stages of the sample preparation procedure.

Related

  1. Self-aggregation, dilational surface rheology and foaming properties of 1-O-dodecyl diglyceryl ether compared to n-dodecyl-β-D-maltoside and pentaethyleneglycol monododecyl ether
    Lucie Delforce, Véronique Nardello-Rataj, Raphaël Lebeuf +2
    Journal of Molecular LiquidsPeer-reviewedLicence not stated12 citedOrganic chemistryHAL
  2. Material-Level Shrinkage and Tensile-Performance Screening of High-Strength Polyethylene-Fibre Engineered Cementitious Composite (PE-ECC) Mortar: MgO Versus Liquid Shrinkage-Reducing Admixture
    Qi Lu, Xian Zhou, Xian Wu +3
    PolymersPeer-reviewedCC BY 4.0Materials & polymersCrossref
  3. Hydroxyl-Terminated Polyethylene Glycol Evades Human Pre-existing Anti-polyethylene Glycol Antibodies
    Tianhao Ding, Jiaru Fu, Min Yang +11
    ACS NanoPeer-reviewedLicence not stated15 citedMaterials & polymersOpenAlex
  4. Porosity Formation Mechanisms and Their Effects on the Mechanical Properties of High-Density Polyethylene Extrusion Welds
    PolymersPeer-reviewedCC BYFull textMaterials & polymersEurope PMC
  5. Chlorinated polyethylene nanocomposites using PCL/clay nanohybrid masterbatches
    Samira Benali, Sophie Peeterbroeck, Patrick Brocorens +5
    European Polymer JournalPeer-reviewedLicence not statedFull text21 citedMaterials & polymersHAL
BibTeX
@article{gintar2026ndodecylβdmaltoside,
  title = {{N-Dodecyl-β-D-Maltoside Replaces Polyethylene Glycol in Reducing Peptide Losses in Autosampler Vials.}},
  author = {Petr Gintar and Ondřej Bucek and David Potěšil and Zbyněk Zdráhal},
  journal = {Proteomes},
  year = {2026},
  month = nov,
  doi = {10.3390/proteomes14040060},
  url = {https://europepmc.org/article/MED/43081333},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - N-Dodecyl-β-D-Maltoside Replaces Polyethylene Glycol in Reducing Peptide Losses in Autosampler Vials.
AU  - Petr Gintar
AU  - Ondřej Bucek
AU  - David Potěšil
AU  - Zbyněk Zdráhal
PY  - 2026
DA  - 2026/11/13
JO  - Proteomes
DO  - 10.3390/proteomes14040060
UR  - https://europepmc.org/article/MED/43081333
AB  - Background: Sample loss during preparation is one of the issues in unveiling the complexity of the proteome. Here, we focused on minimizing peptide loss during their transfer and storage in autosampler vials prior to analysis. Methods: We used commercially available autosampler TPX vials and HeLa digest. Samples were acidified by formic acid, trifluoracetic acid or their combination and supplemented by polyethylene glycol (PEG, our commonly used additive), n-dodecyl-β-D-maltoside (DDM) or no additive at all. For each injection, 10 ng of peptides was administered at a volume of 10 µL; all samples were analyzed by LC-MS/MS. Results: The DDM-containing samples were able to minimize peptide losses. The addition of DDM outperformed the PEG in observed parameters such as the number of identified peptides throughout the LC gradient or the reduction in losses of high-mass peptides. DDM minimizes peptide losses in samples stored in the autosampler vials for at least seventy-two hours. Conclusions: Under the given experimental conditions, the addition of DDM is capable of replacing PEG and can be used to minimize peptide losses in autosampler vials. The use of DDM is therefore particularly advantageous for those types of samples where DDM cannot be used in the earlier stages of the sample preparation procedure.
SN  - 2227-7382
ER  -