Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 38 min ago
Peer-reviewedCC BY-NCInfection and drug resistance

Nanopore Targeted Sequencing for Suspected Bloodstream Infections: Pathogen Detection, Diagnostic Performance, and Potential Impact on Antimicrobial Management.

  1. 1Department of Clinical Laboratory, Wuhan Asia General Hospital, Wuhan Asia General Hospital Affiliated to Wuhan University of Science and Technology, Wuhan, 430056, People's Republic of China.
  2. 2R&D Department, Wuhan EasyDiagnosis Biomedicine Co., Ltd, Wuhan, 430074, People's Republic of China.

Abstract

Background

Rapid and accurate pathogen identification is essential for the management of bloodstream infection (BSI), but blood culture (BC) has limitations in detection yield and turnaround time. We evaluated the complementary value of nanopore targeted sequencing (NTS) alongside BC in patients with suspected BSI, focusing on pathogen detection, diagnostic performance, and antimicrobial management.Methods

This single-center retrospective cohort study included 238 patients who underwent NTS and BC within a 24-hour sample-submission interval. Diagnostic performance was assessed against the final clinical diagnosis documented during routine care, with viral detections excluded when defining NTS positivity. Paired positivity rates and sensitivities were compared using two-sided exact McNemar tests. NTS laboratory turnaround time (TAT) and antimicrobial management were summarized descriptively.Results

BSI was clinically diagnosed in 62 patients (26.1%). Overall positivity was higher for NTS than BC (31.9% [76/238] versus 12.2% [29/238]; P < 0.001), and remained higher after excluding viral detections (19.3% [46/238] versus 12.2% [29/238]; P = 0.0033). Sensitivity was 72.6% for NTS and 46.8% for BC (P = 0.0052). Specificity was 99.4% and 100%, respectively, with one false-positive NTS result versus none for BC. Positive predictive value (PPV) and negative predictive value (NPV) were 97.8% and 91.1% for NTS, compared with 100% and 84.2% for BC. The combined strategy, defined as positive if either test was positive, yielded sensitivity, specificity, PPV, and NPV of 83.9%, 99.4%, 98.1%, and 94.6%, respectively. The estimated NTS laboratory TAT was approximately 6.3 h for 80% of samples. In the non-randomized management subgroup of 53 patients, decisions were reported as NTS-informed in 33 and BC-informed in 20. De-escalation, escalation, and no change occurred in 9/33 (27.3%), 11/33 (33.3%), and 13/33 (39.4%) in the NTS-informed group, respectively. Corresponding figures in the BC-informed group were 4/20 (20.0%), 9/20 (45.0%), and 7/20 (35.0%).Conclusion

NTS showed higher pathogen detection positivity and diagnostic sensitivity than BC, with a short estimated laboratory TAT. Combining NTS with BC increased sensitivity, supporting their complementary use. NTS may also provide clinically actionable microbiological information to support antimicrobial treatment adjustment. Diagnostic performance estimates may be optimistic because of potential incorporation bias.

Related

  1. Performance of Direct Identification and EUCAST Rapid Antimicrobial Susceptibility Testing in Bloodstream Infections Using Sepsityper® and Disk Diffusion Methods
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Bloodstream Infections in Patients with Malignancy: Microbiological Epidemiology, Antimicrobial Resistance, and Factors Associated with Mortality in a Nine-Year Single-Center Retrospective Cohort
    Cihan Yeşil, Cemile Arslan Yeşil, Ferhat Yılmaz +2
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Rapid Phenotypic Antimicrobial Susceptibility Testing and Rapid Molecular Identification with Resistance-Marker Detection for Bloodstream Infections: A Systematic Review with Separate Narrative Syntheses
    Mohamed Elsayed, Mohamed Ibrahim, Hisham Yousif +6
    Medical sciences (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Pathogen-dependent diagnostic performance of plasma metagenomic next-generation sequencing in HIV-associated opportunistic infections
    Zhen-Yu Xu, Yong-Fang Jiang, Yan He +2
    Frontiers in Cellular and Infection MicrobiologyPeer-reviewedCC BY 4.0Full textInfectious diseasePMCEurope PMC
  5. Antimicrobial Resistance in Neonatal and Pediatric Hospital-Onset Bloodstream Infections: Evidence from Neonatal Units and Community Comparators
    Mohammad Elkossi, Shimaa Elwardany Aly, Amira Elhoufey +7
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Full textGeneral medicineCrossrefEurope PMC
BibTeX
@article{wang2026nanopore,
  title = {{Nanopore Targeted Sequencing for Suspected Bloodstream Infections: Pathogen Detection, Diagnostic Performance, and Potential Impact on Antimicrobial Management.}},
  author = {Dong Wang and Hui Wang and Luo Yang and Rui Liao and Tao Fang and Dan Zhang},
  journal = {Infection and drug resistance},
  year = {2026},
  month = nov,
  doi = {10.2147/idr.s652942},
  url = {https://europepmc.org/article/MED/43054940},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Nanopore Targeted Sequencing for Suspected Bloodstream Infections: Pathogen Detection, Diagnostic Performance, and Potential Impact on Antimicrobial Management.
AU  - Dong Wang
AU  - Hui Wang
AU  - Luo Yang
AU  - Rui Liao
AU  - Tao Fang
AU  - Dan Zhang
PY  - 2026
DA  - 2026/11/14
JO  - Infection and drug resistance
DO  - 10.2147/idr.s652942
UR  - https://europepmc.org/article/MED/43054940
AB  - Background  Rapid and accurate pathogen identification is essential for the management of bloodstream infection (BSI), but blood culture (BC) has limitations in detection yield and turnaround time. We evaluated the complementary value of nanopore targeted sequencing (NTS) alongside BC in patients with suspected BSI, focusing on pathogen detection, diagnostic performance, and antimicrobial management.Methods  This single-center retrospective cohort study included 238 patients who underwent NTS and BC within a 24-hour sample-submission interval. Diagnostic performance was assessed against the final clinical diagnosis documented during routine care, with viral detections excluded when defining NTS positivity. Paired positivity rates and sensitivities were compared using two-sided exact McNemar tests. NTS laboratory turnaround time (TAT) and antimicrobial management were summarized descriptively.Results  BSI was clinically diagnosed in 62 patients (26.1%). Overall positivity was higher for NTS than BC (31.9% [76/238] versus 12.2% [29/238]; P < 0.001), and remained higher after excluding viral detections (19.3% [46/238] versus 12.2% [29/238]; P = 0.0033). Sensitivity was 72.6% for NTS and 46.8% for BC (P = 0.0052). Specificity was 99.4% and 100%, respectively, with one false-positive NTS result versus none for BC. Positive predictive value (PPV) and negative predictive value (NPV) were 97.8% and 91.1% for NTS, compared with 100% and 84.2% for BC. The combined strategy, defined as positive if either test was positive, yielded sensitivity, specificity, PPV, and NPV of 83.9%, 99.4%, 98.1%, and 94.6%, respectively. The estimated NTS laboratory TAT was approximately 6.3 h for 80% of samples. In the non-randomized management subgroup of 53 patients, decisions were reported as NTS-informed in 33 and BC-informed in 20. De-escalation, escalation, and no change occurred in 9/33 (27.3%), 11/33 (33.3%), and 13/33 (39.4%) in the NTS-informed group, respectively. Corresponding figures in the BC-informed group were 4/20 (20.0%), 9/20 (45.0%), and 7/20 (35.0%).Conclusion  NTS showed higher pathogen detection positivity and diagnostic sensitivity than BC, with a short estimated laboratory TAT. Combining NTS with BC increased sensitivity, supporting their complementary use. NTS may also provide clinically actionable microbiological information to support antimicrobial treatment adjustment. Diagnostic performance estimates may be optimistic because of potential incorporation bias.
SN  - 1178-6973
ER  -