Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 1 min ago
PreprintarXiv licencearXiv

Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT

Abstract

Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline

Related

  1. Fully automatic airway segmentation in CT images via dual-stage neural network with topology-constrained centerline completion
    Harmony Yuan, Yuan Cheng, Chengxi Yan +4
    Quantitative imaging in medicine and surgeryPeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  2. A hybrid reaction-diffusion system to shed light on ecological transitions between boreal and temperate forests
    Sully Mak, Guillaume Cantin, Benoît Delahaye
    Discrete and Continuous Dynamical Systems - Series SPeer-reviewedPublisher termsFull textEpidemiology & public healthHAL
  3. Extensive bilateral adrenal calcification in von Hippel-Lindau syndrome–associated pheochromocytoma
    JCEM case reportsPeer-reviewedCC BY-NCFull textEndocrinology & metabolismEurope PMC
  4. Bilateral Urolithiasis as the Primary Manifestation of Sarcoidosis
    Wataru Sone, Masaya Kinjou, Taito Miyake
    Internal MedicinePeer-reviewedCC BY-NC-NDFull textPhysiologyJ-STAGE
  5. Bilateral Pulmonary Arterial Involvement in Takayasu Arteritis
    Yuta Inoue, Michihito Kono, Tatsuya Atsumi
    Balkan Medical JournalPeer-reviewedCC BY-NC-ND 4.0Full textGeneral medicinePMC
BibTeX
@misc{wang2026hybrid,
  title = {{Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT}},
  author = {Quan Wang},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.16047},
  eprint = {2610.16047},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.16047},
}
RIS
TY  - UNPB
TI  - Hybrid Context Forests and Bilateral Viterbi Matching for 3D Rib Centerline Tracing in CT
AU  - Quan Wang
PY  - 2026
DA  - 2026/10/18
PB  - arXiv
DO  - 10.48550/arxiv.2610.16047
UR  - https://arxiv.org/abs/2610.16047
AB  - Automatic extraction and anatomical numbering (R01-R12, L01-L12) of all 24 rib centerlines in thoracic CT is essential for unfolded rib visualization, fracture detection, and surgical navigation, but remains challenging due to adjacent-bone confluence, calcified costal cartilage bridges, kyphotic pose variation, and partial visibility of terminal ribs. We present ribline, an open-source three-stage framework combining: (1) an automatically detected lung-apex and vertebral-midline coordinate frame with a kyphosis-aware azimuthal angle for point ordering along each rib; (2) a hybrid voxel detector fusing an anatomically anchored Semantic Context Forest (SCF) with a lightweight 3D U-Net; and (3) a global stage that decomposes the probability skeleton into candidate curves, assigns rib indices via a bilateral Viterbi dynamic program coupled across both hemithoraces, and refines curves via template recovery and normal-plane centering (RibSnake). On the Siemens Corporate Research 2 mm thoracic CT benchmark (47 training and 12 evaluation scans), our pipeline achieves a labeled Chamfer distance of 2.05 mm, labeled clDice of 0.886 (3 mm) and 0.945 (4 mm), 97.2% labeling accuracy (278/286 ribs), and zero false-positive curves on the evaluation split, and 3.64 mm (median 2.39 mm) with 91.8% labeling accuracy across all 59 annotated scans (1,402 ribs) in 5-fold cross-validation. Code: https://github.com/wq2012/ribline Pretrained Models: https://huggingface.co/collections/wq2012/ribline
ER  -