Skip to content
DraconiticResearch
Search Sources API
197,693 studies31 sourcesUpdated 48 min ago
PreprintCC BY 4.0arXiv

Elastic Multi-Fidelity Bayesian Model Calibration

Abstract

Bayesian calibration of functional-output computer models typically relies on dimension reduction techniques, such as functional principal component analysis, which assume that differences among simulator realizations arise only from amplitude variation. When simulator output also exhibits phase variation such as shifts in the timing or location of key features, this assumption is violated. Recent work has addressed this issue through elastic calibration, which aligns functional computer model realizations with observed experimental data prior to dimension reduction. Separately, multi-fidelity methods reduce the cost of calibration by supplementing a small number of expensive high-fidelity simulator runs with a larger ensemble of cheap low-fidelity runs. This is typically done through either a mapping strategy, which corrects low-fidelity predictions toward high-fidelity output, or a fusion strategy, which builds a shared basis across both fidelities. This paper combines these two lines of work, introducing elastic multi-fidelity Bayesian model calibration, which aligns high- and low-fidelity functional output to a common reference before applying multi-fidelity mapping or fusion. On a synthetic two-dimensional calibration problem and a dynamic material properties equation-of-state problem, both elastic multi-fidelity strategies match or improve on the leave-one-out predictive accuracy of a mono-fidelity elastic emulator, with the fusion approach achieving the lowest error. Both strategies also produce tighter calibrated posteriors than the mono-fidelity baseline, with the fusion approach providing the best coverage and parameter estimates closest to the true values.

Related

  1. Bayesian Calibration with Functional Outputs Using Elastic Partial Matching
    Paul Casteras, Julien Bect, Josselin Garnier +1
    HALPreprintCC BY-NC-ND 4.0Full textStatisticsHALarXiv
  2. MF-SCBO : Multi-fidelity Scalable Constrained Bayesian Optimization
    Lucas Palazzolo, Mickaël Binois, Laëtitia Giraldi
    HALPreprintCC BY 4.0Full textOptimisation & controlHALarXiv
  3. Reduced-Space Multi-Fidelity Bayesian Optimization of Process Simulation Models
    Niki Triantafyllou, Andrea Bernardi, Maria M. Papathanasiou
    arXivPreprintarXiv licenceFull textOptimisation & controlarXiv
  4. The Staged Pandora's Box: Reservation Indices for Multi-Fidelity Bayesian Optimization
    Long Vu, Jongseong Brad Choi, Binoy Ravindran +1
    arXivPreprintarXiv licenceFull textOptimisation & controlStatisticsarXiv
  5. Bayesian Emulation of Multi-fidelity Earth System Modelling Using Hierarchical Gaussian Processes
    Xiaoyu Xiong, Louise Kimpton, Huiyi Yang +3
    arXivPreprintCC BY 4.0Full textStatisticsarXiv
BibTeX
@misc{tucker2026elastic,
  title = {{Elastic Multi-Fidelity Bayesian Model Calibration}},
  author = {J. Derek Tucker and Gavin Collins and Gabriel Huerta and Justin L. Brown},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.27174},
  eprint = {2609.27174},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.27174},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Elastic Multi-Fidelity Bayesian Model Calibration
AU  - J. Derek Tucker
AU  - Gavin Collins
AU  - Gabriel Huerta
AU  - Justin L. Brown
PY  - 2026
DA  - 2026/09/23
PB  - arXiv
DO  - 10.48550/arxiv.2609.27174
UR  - https://arxiv.org/abs/2609.27174
AB  - Bayesian calibration of functional-output computer models typically relies on dimension reduction techniques, such as functional principal component analysis, which assume that differences among simulator realizations arise only from amplitude variation. When simulator output also exhibits phase variation such as shifts in the timing or location of key features, this assumption is violated. Recent work has addressed this issue through elastic calibration, which aligns functional computer model realizations with observed experimental data prior to dimension reduction. Separately, multi-fidelity methods reduce the cost of calibration by supplementing a small number of expensive high-fidelity simulator runs with a larger ensemble of cheap low-fidelity runs. This is typically done through either a mapping strategy, which corrects low-fidelity predictions toward high-fidelity output, or a fusion strategy, which builds a shared basis across both fidelities. This paper combines these two lines of work, introducing elastic multi-fidelity Bayesian model calibration, which aligns high- and low-fidelity functional output to a common reference before applying multi-fidelity mapping or fusion. On a synthetic two-dimensional calibration problem and a dynamic material properties equation-of-state problem, both elastic multi-fidelity strategies match or improve on the leave-one-out predictive accuracy of a mono-fidelity elastic emulator, with the fusion approach achieving the lowest error. Both strategies also produce tighter calibrated posteriors than the mono-fidelity baseline, with the fusion approach providing the best coverage and parameter estimates closest to the true values.
ER  -