Field validation of a commercial pasteurization system for heat-treating individual bags of bovine colostrum
4 affiliations
- 1Department of Veterinary Population Medicine, University of Minnesota, St. Paul, MN 55108
- 2Department of Dairy and Food Sciences, South Dakota State University, Brookings, SD 57007
- 3CalfStart LLC, Altura, MN 55910
- 4Superior Cattle Solutions, Madison, GA 30650
Abstract
Our primary objective was to evaluate the effects on IgG and bacteria concentrations of using a commercial pasteurizer system (Matilda Colostrum Pasteurizer and Warmer, DairyTech Inc., Windsor, CO) to heat-treat (HT) individual bags (3.8 L) of bovine colostrum, as compared with treating larger volumes of pooled colostrum (>57 L) in a vat pasteurizer. A secondary objective was to describe concentrations of IgG and bacteria in pre-HT versus post-HT colostrum, whether processed using the Matilda pasteurizer for small volumes or a vat pasteurizer system for large volumes. The study was conducted in summer 2024 on a commercial Midwest Holstein dairy. Each day, high quality (Brix >22%; estimated IgG >50 g/L) colostrum was selected and pooled to create a single unique batch (57–95 L [15–25 gallons; gal]), then transferred into the on-farm 144-L (30 gal) vat pasteurizer. After mixing well and collecting aseptic samples for later testing, 3.8 L were transferred from the pool into a 4-L single-use disposable bag (Perfect Udder [PU] bag system, DairyTech Inc.) which was then placed in a small commercial colostrum pasteurizer system (Matilda Pasteurizer and Warmer, DairyTech Inc.). The large pool and the single bag of colostrum were both then HT in the vat pasteurizer (VAT) and Matilda pasteurizer system (MAT), respectively, at 60°C (140°F) for 60 min. Following rapid cooling to 15.5°C (60°F), aseptic samples of post-HT colostrum were collected from both the VAT and MAT systems and frozen (−20°C) for later analysis. Pre-HT colostrum from the original fresh pool and post-HT colostrum collected from both the VAT and MAT pasteurizer systems were submitted for determination of IgG concentration (g/L) using an radial immunodiffusion assay, as well as aerobic culture to determine total plate count (TPC; cfu/mL) and total coliform count (TCC; cfu/mL). For objective 1, linear regression was used to evaluate if IgG, TPC, or TCC in post-HT colostrum varied by HT method (VAT vs. MAT). For objective 2, after stratifying the data by pasteurization method (VAT or MAT), linear regression was used to evaluate if IgG, TPC, or TCC concentrations were different between the pre- and post-HT samples. Results from 24 unique batches of colostrum showed no effect of HT method on mean (±SE) concentrations of IgG, TPC, or TCC in post-HT colostrum processed using the VAT method (82.7 ± 2.19 g/L; 2.64 ± 0.14 log10 cfu/mL; 0.20 ± 0.09 log10 cfu/mL, respectively) as compared with the MAT method (82.9 ± 2.19 g/L; 2.96 ± 0.14 log10 cfu/mL; 0.07 ± 0.09 log10 cfu/mL, respectively). Furthermore, whether processing a larger volume in the VAT system or a small volume in the MAT system, HT resulted in no reduction in IgG, but significantly reduced bacteria levels in post-HT (vs. pre-HT) colostrum. These results show that under the conditions of this study on a single commercial dairy farm, we achieved equally high quality and equally clean colostrum for calves, whether using a vat pasteurizer system for large volumes or using individual bags using the Matilda pasteurizer system for small volumes.
Related
- Loss of confidence in commercial antibody validation threatens biomedical research integrity
- High-pressure processing and thermal pasteurization of blueberry purée-based baby food differentially modulate polyphenol bioaccessibility and intestinal cell responses
- Early blood biochemical changes following colostrum intake in newborn Murrah buffalo calves: an observational study
- Effects of a mushroom-based β-glucan and bovine colostrum blend on the gastrointestinal health and immune function of healthy adult dogs
- Variation in Colostrum Brix Values and Associations Between Initial Body Weight, Colostrum Intake and Piglet Survival from 24 h to Weaning in a Swedish Sow Herd
BibTeX
@article{godden2026field,
title = {{Field validation of a commercial pasteurization system for heat-treating individual bags of bovine colostrum}},
author = {Sandra M. Godden and Kenson Boelke and Destiny Smith and Isabela Karels and Robert Schell and Adam Geiger and Whitney A. Knauer},
journal = {JDS communications},
year = {2026},
month = aug,
doi = {10.3168/jdsc.2026-1081},
url = {https://europepmc.org/article/PMC/PMC13751267},
note = {CC BY},
}
RIS
TY - JOUR
TI - Field validation of a commercial pasteurization system for heat-treating individual bags of bovine colostrum
AU - Sandra M. Godden
AU - Kenson Boelke
AU - Destiny Smith
AU - Isabela Karels
AU - Robert Schell
AU - Adam Geiger
AU - Whitney A. Knauer
PY - 2026
DA - 2026/08/03
JO - JDS communications
DO - 10.3168/jdsc.2026-1081
UR - https://europepmc.org/article/PMC/PMC13751267
AB - Our primary objective was to evaluate the effects on IgG and bacteria concentrations of using a commercial pasteurizer system (Matilda Colostrum Pasteurizer and Warmer, DairyTech Inc., Windsor, CO) to heat-treat (HT) individual bags (3.8 L) of bovine colostrum, as compared with treating larger volumes of pooled colostrum (>57 L) in a vat pasteurizer. A secondary objective was to describe concentrations of IgG and bacteria in pre-HT versus post-HT colostrum, whether processed using the Matilda pasteurizer for small volumes or a vat pasteurizer system for large volumes. The study was conducted in summer 2024 on a commercial Midwest Holstein dairy. Each day, high quality (Brix >22%; estimated IgG >50 g/L) colostrum was selected and pooled to create a single unique batch (57–95 L [15–25 gallons; gal]), then transferred into the on-farm 144-L (30 gal) vat pasteurizer. After mixing well and collecting aseptic samples for later testing, 3.8 L were transferred from the pool into a 4-L single-use disposable bag (Perfect Udder [PU] bag system, DairyTech Inc.) which was then placed in a small commercial colostrum pasteurizer system (Matilda Pasteurizer and Warmer, DairyTech Inc.). The large pool and the single bag of colostrum were both then HT in the vat pasteurizer (VAT) and Matilda pasteurizer system (MAT), respectively, at 60°C (140°F) for 60 min. Following rapid cooling to 15.5°C (60°F), aseptic samples of post-HT colostrum were collected from both the VAT and MAT systems and frozen (−20°C) for later analysis. Pre-HT colostrum from the original fresh pool and post-HT colostrum collected from both the VAT and MAT pasteurizer systems were submitted for determination of IgG concentration (g/L) using an radial immunodiffusion assay, as well as aerobic culture to determine total plate count (TPC; cfu/mL) and total coliform count (TCC; cfu/mL). For objective 1, linear regression was used to evaluate if IgG, TPC, or TCC in post-HT colostrum varied by HT method (VAT vs. MAT). For objective 2, after stratifying the data by pasteurization method (VAT or MAT), linear regression was used to evaluate if IgG, TPC, or TCC concentrations were different between the pre- and post-HT samples. Results from 24 unique batches of colostrum showed no effect of HT method on mean (±SE) concentrations of IgG, TPC, or TCC in post-HT colostrum processed using the VAT method (82.7 ± 2.19 g/L; 2.64 ± 0.14 log10 cfu/mL; 0.20 ± 0.09 log10 cfu/mL, respectively) as compared with the MAT method (82.9 ± 2.19 g/L; 2.96 ± 0.14 log10 cfu/mL; 0.07 ± 0.09 log10 cfu/mL, respectively). Furthermore, whether processing a larger volume in the VAT system or a small volume in the MAT system, HT resulted in no reduction in IgG, but significantly reduced bacteria levels in post-HT (vs. pre-HT) colostrum. These results show that under the conditions of this study on a single commercial dairy farm, we achieved equally high quality and equally clean colostrum for calves, whether using a vat pasteurizer system for large volumes or using individual bags using the Matilda pasteurizer system for small volumes.
SN - 2666-9102
ER -