Implementation of an Internalized Hemolysis Assessment Approach in Targeted Bottom-Up Proteomics for the Purpose of Blood Plasma Sample Quality Control
- 1Research Institute for Systems Biology and Medicine, Moscow 117246, Russia
- 2National Medical Research Center “Treatment and Rehabilitation Center” Of the Ministry of Health of the Russian Federation, Moscow 12109, Russia
Abstract
Mishandling of samples during blood plasma preparation may lead to biases in proteomic analysis and misinterpretation of data. An earlier study by Geyer et al. (2019) described proteins that may indicate poor plasma sample quality. Following this work, we have imitated a triangular strategy for biomarker discovery, established a targeted quantitative method for panels of hemolyzed and coagulated plasma sample markers proposed in the previous study, and validated it in our own model experiment. We have developed a scale for estimating the degree (rate) of hemolysis based on several protein markers and investigated the feasibility of using an internal control approach to detect hemolysis in targeted proteomic analysis. We propose including our plasma sample quality assessment and associated sample exclusion criteria into standard MRM analyses to provide more reliable data for proteomic research.
Related
- Single Cell Proteomics to Spatial Multiomics in Cardiovascular Disease: Foundations, Technologies, and Biological Insights
- Emerging Roles of Mass Spectrometry–Based Proteomics in Drug Discovery
- MSRyzen: An Agentic Platform for Unified Proteomics Analysis and Evidence-Centric Visualization
- Empirical-Bayes and Bayesian Hierarchical Modelling for Missingness and Differential Expression in Proteomics
- Cell-type resolved prenylomics in mouse liver enabled by a low-input proteomics workflow
BibTeX
@article{vakaryuk2026implementation,
title = {{Implementation of an Internalized Hemolysis Assessment Approach in Targeted Bottom-Up Proteomics for the Purpose of Blood Plasma Sample Quality Control}},
author = {Anastasia V. Vakaryuk and Ivan O. Butenko and Natalia A. Kitsilovskaya and Alexey V. Kovalenko and Veronica D. Gremyacheva and Grigory L. Kozhemyakin and Angelina A. Lebedeva and Nikita M. Baraboshkin and Oleg V. Fedorov and Olga V. Kurilova and Konstantin S. Gorbunov and Irina V. Kolesnikova and Lyubov A. Davydova and Vadim M. Govorun},
journal = {Journal of Proteome Research},
year = {2026},
month = sep,
doi = {10.1021/acs.jproteome.6c00157},
url = {https://doi.org/10.1021/acs.jproteome.6c00157},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Implementation of an Internalized Hemolysis Assessment Approach in Targeted Bottom-Up Proteomics for the Purpose of Blood Plasma Sample Quality Control
AU - Anastasia V. Vakaryuk
AU - Ivan O. Butenko
AU - Natalia A. Kitsilovskaya
AU - Alexey V. Kovalenko
AU - Veronica D. Gremyacheva
AU - Grigory L. Kozhemyakin
AU - Angelina A. Lebedeva
AU - Nikita M. Baraboshkin
AU - Oleg V. Fedorov
AU - Olga V. Kurilova
AU - Konstantin S. Gorbunov
AU - Irina V. Kolesnikova
AU - Lyubov A. Davydova
AU - Vadim M. Govorun
PY - 2026
DA - 2026/09/23
JO - Journal of Proteome Research
DO - 10.1021/acs.jproteome.6c00157
UR - https://doi.org/10.1021/acs.jproteome.6c00157
AB - Mishandling of samples during blood plasma preparation may lead to biases in proteomic analysis and misinterpretation of data. An earlier study by Geyer et al. (2019) described proteins that may indicate poor plasma sample quality. Following this work, we have imitated a triangular strategy for biomarker discovery, established a targeted quantitative method for panels of hemolyzed and coagulated plasma sample markers proposed in the previous study, and validated it in our own model experiment. We have developed a scale for estimating the degree (rate) of hemolysis based on several protein markers and investigated the feasibility of using an internal control approach to detect hemolysis in targeted proteomic analysis. We propose including our plasma sample quality assessment and associated sample exclusion criteria into standard MRM analyses to provide more reliable data for proteomic research.
SN - 1535-3893
SN - 1535-3907
ER -