Enhanced biocompatibility and efficacy of a newly developed plastic biliary stent: a porcine model study.
6 affiliations
- 1Department of Internal Medicine, Hallym University Dongtan Sacred Heart Hospital, Hallym University College of Medicine, Hwaseong, Korea.
- 2Department of Internal Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
- 3Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
- 4Department of Pathology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
- 5Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea. [email protected].
- 6Department of Internal Medicine, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea. [email protected].
Abstract
Background
Plastic stents are widely used in endoscopic biliary drainage. However, limitations such as poor conformability, migration, biofilm-induced obstruction, and limited radiographic visibility remain unresolved. This study aimed to evaluate the efficacy and safety of the newly designed stent using in vitro mechanical tests and an in vivo porcine biliary stricture model.Methods
All stents were classified into four groups: Group 1, commercial double pigtail; Group 2, new double pigtail; Group 3, proximal half-bend with distal pigtail stent; and Group 4, double half-bend stent. The drainage performance and mechanical properties were assessed using in vitro evaluations. A mini-pig biliary stricture model was used for in vivo validation. Stents were endoscopically inserted and maintained for 4 weeks. Outcomes included radiographic migration, biochemical parameters, biofilm/sludge assessment, luminal patency, and histological analysis of bile duct tissue.Results
Groups 3 and 4 showed favorable exploratory findings in tissue reactivity, luminal patency, and positional stability compared with Group 1. Stent migration occurred in 1/4 animals in Group 1 and in 0/4 animals in Groups 2-4. Because multiple structural modifications were introduced simultaneously, the observed findings could not be attributed to an individual design component. Radiopaque markers enhanced visibility under fluoroscopic guidance, facilitating real-time confirmation of the stent position.Conclusions
In this exploratory preclinical study, the newly developed stents showed favorable mechanical, histological, and luminal-patency findings. These results require confirmation in larger preclinical studies and prospective clinical investigations.
Related
- Endoscopic closure of plastic biliary stent-induced duodenal perforation opposite the major papilla using anchor pronged clips
- Metallic versus plastic stents for the management of biliary obstruction : A GRADE-assessed systematic review and meta-analysis
- Segment-Specific Occlusion of Retrieved Plastic Biliary Stents: Direct Quantification and Microbial and Material Determinants.
- Staged Endoscopic Extraction of a Chronically Impacted Biliary Plastic Stent Using Temporary Parallel Decompression in a Resource-Limited Setting: A Case Report.
- Enhanced colloidal stability and biocompatibility of PVA-coated Fe₃O₄ nanoparticles for potential magnetic resonance imaging applications
BibTeX
@article{jung2026enhanced,
title = {{Enhanced biocompatibility and efficacy of a newly developed plastic biliary stent: a porcine model study.}},
author = {Chan Min Jung and See Young Lee and Jung Hyun Jo and Ji Hae Nahm and Cheong Ran Je and Jae Hee Cho and Sung Ill Jang},
journal = {BMC gastroenterology},
year = {2026},
month = sep,
doi = {10.1186/s12876-026-05294-3},
url = {https://europepmc.org/article/MED/43079268},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Enhanced biocompatibility and efficacy of a newly developed plastic biliary stent: a porcine model study.
AU - Chan Min Jung
AU - See Young Lee
AU - Jung Hyun Jo
AU - Ji Hae Nahm
AU - Cheong Ran Je
AU - Jae Hee Cho
AU - Sung Ill Jang
PY - 2026
DA - 2026/09/02
JO - BMC gastroenterology
DO - 10.1186/s12876-026-05294-3
UR - https://europepmc.org/article/MED/43079268
AB - Background Plastic stents are widely used in endoscopic biliary drainage. However, limitations such as poor conformability, migration, biofilm-induced obstruction, and limited radiographic visibility remain unresolved. This study aimed to evaluate the efficacy and safety of the newly designed stent using in vitro mechanical tests and an in vivo porcine biliary stricture model.Methods All stents were classified into four groups: Group 1, commercial double pigtail; Group 2, new double pigtail; Group 3, proximal half-bend with distal pigtail stent; and Group 4, double half-bend stent. The drainage performance and mechanical properties were assessed using in vitro evaluations. A mini-pig biliary stricture model was used for in vivo validation. Stents were endoscopically inserted and maintained for 4 weeks. Outcomes included radiographic migration, biochemical parameters, biofilm/sludge assessment, luminal patency, and histological analysis of bile duct tissue.Results Groups 3 and 4 showed favorable exploratory findings in tissue reactivity, luminal patency, and positional stability compared with Group 1. Stent migration occurred in 1/4 animals in Group 1 and in 0/4 animals in Groups 2-4. Because multiple structural modifications were introduced simultaneously, the observed findings could not be attributed to an individual design component. Radiopaque markers enhanced visibility under fluoroscopic guidance, facilitating real-time confirmation of the stent position.Conclusions In this exploratory preclinical study, the newly developed stents showed favorable mechanical, histological, and luminal-patency findings. These results require confirmation in larger preclinical studies and prospective clinical investigations.