Skip to content
DraconiticResearch
Search Sources API
197,357 studies31 sourcesUpdated 52 min ago
Peer-reviewedCC BYFrontiers in Surgery

Construction of a quality evaluation index system for waterless surgical hand antisepsis in operating rooms

  1. 1epartment of Surgery, The First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China

Abstract

ObjectiveTo develop and obtain expert consensus on a quality evaluation index system for waterless surgical hand antisepsis in operating rooms and to assign hierarchical weights to the finalized indicators.MethodsGuided by the Donabedian structure-process-outcome model, candidate indicators were generated through a structured literature review and semi-structured interviews. A three-round expert consultation was conducted: Rounds 1 and 2 were used to screen and refine indicators, and Round 3 was used for AHP-based pairwise weighting. Twenty-two eligible experts received the Round-1 questionnaire; 20 returned valid questionnaires and constituted the panel retained for Rounds 2 and 3, in which all 20 responded. Expert authority was assessed using Cr = (Ca + Cs)/2. In Round 3, individual expert authority coefficients were normalized to obtain expert-specific weights, and pairwise judgments were aggregated using a weighted geometric mean before AHP weight calculation and consistency testing.ResultsThe valid response rates were 90.9% (20/22), 100% (20/20), and 100% (20/20) in Rounds 1, 2, and 3, respectively. The panel mean expert authority coefficients (Cr) were 0.883, 0.895, and 0.900. Kendall's coefficients of concordance for the two indicator-screening rounds were 0.242 and 0.334, respectively (both P < 0.001), while coefficients of variation decreased from 0.07-0.20 to 0.05-0.18. The aggregated AHP group judgment matrices satisfied the predefined consistency criterion (CR < 0.10). The final system comprised three first-level, nine second-level, and 28 third-level indicators. The global weights of the first-level domains were structure 0.1762, process 0.4123, and outcome 0.4115.ConclusionThis study produced a consensus-based and hierarchically weighted quality evaluation index system for waterless surgical hand antisepsis. The framework may support standardized quality assessment and future quality-improvement work; however, the present study establishes expert consensus and relative priorities rather than clinical effectiveness, psychometric reliability, or causal effects. Multicenter clinical validation is required before broad implementation.

Related

  1. Evaluation of a mobile surgical air decontamination device in reducing airborne microbial load in the operating theatre of a tertiary care hospital.
    Naseeruddin Mohammed, Santosh Karade, Mohammed Ashraf Ali Namaji +2
    Infection prevention in practicePeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Applicator-Based Versus Bulk-Bottle Delivery of the Same Alcoholic Chlorhexidine: A Single-Center, Non-Randomized Pilot Micro-Costing Study of Two Surgical Skin-Antisepsis Workflows.
    Francisco Guillen-Grima, Maria Pilar Garcia-Garcia, Laura Guillen-Aguinaga +3
    Healthcare (Basel, Switzerland)Peer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  3. From Person to Patient: Power, Control and the Construction of Vulnerability in the Operating Room.
    Mirko Prosen
    Nursing inquiryPeer-reviewedCC BYFull textEpidemiology & public healthEurope PMC
  4. Virtual Operating Theatre Simulation: Development and Evaluation of a Web-Based Learning Tool for Medical Students
    Thiruselvi Subramaniam, Chew Fei Sow, Siti Azreena Binti Mubin +1
    Medical Science EducatorPeer-reviewedLicence not statedFull textPhysiologyPMC
  5. The cognition of dynamic evaluation of operating room environmental quality among medical staff: a qualitative study
    Yanan Li, Tong Zhang, Dongmei Bian
    Frontiers in Public HealthPeer-reviewedCC BY 4.0Full textEpidemiology & public healthCrossrefEurope PMCEurope PMCPMC
BibTeX
@article{yang2026construction,
  title = {{Construction of a quality evaluation index system for waterless surgical hand antisepsis in operating rooms}},
  author = {Songping Yang and Xi Yuan and Xuequn Yin and Wenjuan Zhou and Huixian Zhou and Li Miao and Guo Zhang and Xinmei Zhang},
  journal = {Frontiers in Surgery},
  year = {2026},
  month = oct,
  doi = {10.3389/fsurg.2026.1949101},
  url = {https://doi.org/10.3389/fsurg.2026.1949101},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Construction of a quality evaluation index system for waterless surgical hand antisepsis in operating rooms
AU  - Songping Yang
AU  - Xi Yuan
AU  - Xuequn Yin
AU  - Wenjuan Zhou
AU  - Huixian Zhou
AU  - Li Miao
AU  - Guo Zhang
AU  - Xinmei Zhang
PY  - 2026
DA  - 2026/10/29
JO  - Frontiers in Surgery
DO  - 10.3389/fsurg.2026.1949101
UR  - https://doi.org/10.3389/fsurg.2026.1949101
AB  - ObjectiveTo develop and obtain expert consensus on a quality evaluation index system for waterless surgical hand antisepsis in operating rooms and to assign hierarchical weights to the finalized indicators.MethodsGuided by the Donabedian structure-process-outcome model, candidate indicators were generated through a structured literature review and semi-structured interviews. A three-round expert consultation was conducted: Rounds 1 and 2 were used to screen and refine indicators, and Round 3 was used for AHP-based pairwise weighting. Twenty-two eligible experts received the Round-1 questionnaire; 20 returned valid questionnaires and constituted the panel retained for Rounds 2 and 3, in which all 20 responded. Expert authority was assessed using Cr = (Ca + Cs)/2. In Round 3, individual expert authority coefficients were normalized to obtain expert-specific weights, and pairwise judgments were aggregated using a weighted geometric mean before AHP weight calculation and consistency testing.ResultsThe valid response rates were 90.9% (20/22), 100% (20/20), and 100% (20/20) in Rounds 1, 2, and 3, respectively. The panel mean expert authority coefficients (Cr) were 0.883, 0.895, and 0.900. Kendall's coefficients of concordance for the two indicator-screening rounds were 0.242 and 0.334, respectively (both P < 0.001), while coefficients of variation decreased from 0.07-0.20 to 0.05-0.18. The aggregated AHP group judgment matrices satisfied the predefined consistency criterion (CR < 0.10). The final system comprised three first-level, nine second-level, and 28 third-level indicators. The global weights of the first-level domains were structure 0.1762, process 0.4123, and outcome 0.4115.ConclusionThis study produced a consensus-based and hierarchically weighted quality evaluation index system for waterless surgical hand antisepsis. The framework may support standardized quality assessment and future quality-improvement work; however, the present study establishes expert consensus and relative priorities rather than clinical effectiveness, psychometric reliability, or causal effects. Multicenter clinical validation is required before broad implementation.
SN  - 2296-875X
ER  -