Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 54 min ago
Peer-reviewedCC BY-NC-NDBMC ophthalmology

Different vault outcomes following implantable collamer lens implantation in eyes with ciliary body cysts: a case report.

6 affiliations
  1. 1Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China.
  2. 2State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, Qingdao, China.
  3. 3School of Ophthalmology, Shandong First Medical University, Qingdao, China.
  4. 4Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, Qingdao, China. [email protected].
  5. 5State Key Laboratory Cultivation Base, Shandong Key Laboratory of Eye Diseases, Qingdao, China. [email protected].
  6. 6School of Ophthalmology, Shandong First Medical University, Qingdao, China. [email protected].

Abstract

Background

Ciliary body cysts are common incidental findings during preoperative screening for implantable collamer lens (ICL) implantation. Although their presence is generally not considered a contraindication to surgery, cysts extending into the ciliary sulcus may influence haptic seating. The potential contribution of cyst morphology to postoperative ICL behavior remains insufficiently described.Case presentation

We report two myopic patients with ciliary body cysts protruding into the ciliary sulcus who underwent posterior chamber ICL implantation. Preoperative ultrasound biomicroscopy (UBM) was used to evaluate cyst anatomy. Case 1 had a single, qualitatively thin-walled, unilocular cyst and achieved an adequate postoperative vault of 445 μm at 3 months. Postoperative UBM showed a flatter cyst contour at the haptic-cyst interface. Case 2 had two adjacent, relatively thick-walled, multiloculated cysts and developed a persistently low vault, reaching 158 μm at 15 months. Postoperative UBM showed that the cysts maintained a rounded contour and appeared to be associated with posterior displacement of the haptic.Conclusions

These two cases suggest that cyst morphology may be one of several factors associated with postoperative ICL vault in eyes with sulcus-involved ciliary body cysts. Detailed preoperative UBM assessment of cyst structure and sulcus anatomy may be useful for individualized surgical planning and postoperative follow-up. Larger studies are warranted to determine whether specific morphologic characteristics of ciliary body cysts are associated with postoperative ICL haptic behavior and vault outcomes.

Related

  1. Three-Month Ocular Surface and Dry-Eye Outcomes After Implantable Collamer Lens (ICL) Implantation versus Small-Incision Lenticule Extraction (SMILE): A Prospective Non-Randomized Comparative Cohort Study
    Huiyi Du, Huiqing Zhang, Anqi Yuan +1
    Clinical Ophthalmology (Auckland, N.Z.)Peer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  2. Intraoperative OCT observation of incision-related descemet membrane detachment during implantable collamer lens implantation.
    Jiao Xie, Nian Guan, Ying Liu +3
    Frontiers in medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMCPMC
  3. Short- and Long-Term Dynamics of Endothelial Cell Density and Vault Changes After Implantable Collamer Lens Implantation.
    Maria Muzyka-Woźniak, Adam Oleszko, Malwina Terlecka
    Medical sciences (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Accuracy of NK and KS Formulas in Predicting Postoperative Vault at One Month After Implantable Collamer Lens Implantation: A Retrospective Study of 327 Eyes
    Zixiao Liu, Xinhua Liu, Xue Yao +2
    Clinical Ophthalmology (Auckland, N.Z.)Peer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
  5. Longitudinal Changes in Anxiety and Depression Following First Implantable Cardioverter-Defibrillator Implantation: A Prospective Observational Study
    Vincenzo Sgaramella, Antonio Gianluca Robles, Domenico Rosario Riccardo Chieppa +7
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{cui2026different,
  title = {{Different vault outcomes following implantable collamer lens implantation in eyes with ciliary body cysts: a case report.}},
  author = {Wei Cui and Wenjiao Bi and Xiaoming Wu and Mingming Zhou},
  journal = {BMC ophthalmology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12886-026-05121-z},
  url = {https://europepmc.org/article/MED/42958151},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Different vault outcomes following implantable collamer lens implantation in eyes with ciliary body cysts: a case report.
AU  - Wei Cui
AU  - Wenjiao Bi
AU  - Xiaoming Wu
AU  - Mingming Zhou
PY  - 2026
DA  - 2026/08/03
JO  - BMC ophthalmology
DO  - 10.1186/s12886-026-05121-z
UR  - https://europepmc.org/article/MED/42958151
AB  - Background  Ciliary body cysts are common incidental findings during preoperative screening for implantable collamer lens (ICL) implantation. Although their presence is generally not considered a contraindication to surgery, cysts extending into the ciliary sulcus may influence haptic seating. The potential contribution of cyst morphology to postoperative ICL behavior remains insufficiently described.Case presentation  We report two myopic patients with ciliary body cysts protruding into the ciliary sulcus who underwent posterior chamber ICL implantation. Preoperative ultrasound biomicroscopy (UBM) was used to evaluate cyst anatomy. Case 1 had a single, qualitatively thin-walled, unilocular cyst and achieved an adequate postoperative vault of 445 μm at 3 months. Postoperative UBM showed a flatter cyst contour at the haptic-cyst interface. Case 2 had two adjacent, relatively thick-walled, multiloculated cysts and developed a persistently low vault, reaching 158 μm at 15 months. Postoperative UBM showed that the cysts maintained a rounded contour and appeared to be associated with posterior displacement of the haptic.Conclusions  These two cases suggest that cyst morphology may be one of several factors associated with postoperative ICL vault in eyes with sulcus-involved ciliary body cysts. Detailed preoperative UBM assessment of cyst structure and sulcus anatomy may be useful for individualized surgical planning and postoperative follow-up. Larger studies are warranted to determine whether specific morphologic characteristics of ciliary body cysts are associated with postoperative ICL haptic behavior and vault outcomes.
SN  - 1471-2415
ER  -