Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up.
6 affiliations
- 1Pediatric Orthopaedics and Traumatology, University of Helsinki and Helsinki New Children's Hospital, Helsinki, Finland; Department of Surgery, Päijät-Häme Central Hospital, Lahti, Finland.
- 2Department of Orthopaedics and Traumatology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland; Department of Orthopaedics and Traumatology, Kanta-Häme Central Hospital, Hämeenlinna, Finland.
- 3Pediatric Orthopaedics and Traumatology, University of Helsinki and Helsinki New Children's Hospital, Helsinki, Finland; University of Eastern Finland, Kuopio, Finland.
- 4Spine Center, Schulthess Klinik, Zurich, Switzerland.
- 5Pediatric Orthopaedics and Traumatology, University of Helsinki and Helsinki New Children's Hospital, Helsinki, Finland; Department of Orthopaedics and Traumatology, Helsinki University Hospital and University of Helsinki, Helsinki, Finland.
- 6Pediatric Orthopaedics and Traumatology, University of Helsinki and Helsinki New Children's Hospital, Helsinki, Finland. [email protected].
Abstract
Background and purpose
Removal of flexible intramedullary nails (FIN) in children with femoral shaft fractures has been considered unnecessary when nails are left unbent flush to the bone. We aimed to evaluate the frequency and timing of nail removal on demand.Methods
This is an observational follow-up study including consecutive 3-14-year-old children with femoral shaft fractures treated during 2011-2018 with FIN. The instruction was to leave the distal ends of the nails unbent above the distal femoral physis. Alignment of the fracture and position of the nails were assessed after nailing and during follow-up. Data on nail removal rates and timing was collected with at least 5 years of follow-up. The outcomes for children with correctly placed nails were compared with those with nails that were too long, defined as cut at or below the distal femoral physis evaluated from postoperative radiographs.Results
55 consecutive children were included. All fractures healed in satisfactory alignment. FINs were too long in 24 patients (20 distally, 4 proximally). Hardware was removed in 37 (67%) children at a median of 2.4 years from surgery because of pain (range 0.3-9.3). Removal occurred in 21/24 of those with too long nails, and in 16/31 patients with correctly applied FIN, RR 1.7 (95% confidence interval 1.2-2.5, P = 0.005).Conclusion
Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.
Related
- Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence
- Exploring physical recovery in children after intramedullary nailed femoral shaft fractures: a prospective pilot study
- Lateral-Only Flexible Intramedullary Nailing for Pediatric Tibial Shaft Fractures: An Early Comparative Experience With a Novel Technique to Reduce Symptomatic Implant Prominence
- Intramedullary Nailing of Pathological Humerus Diaphyseal Fractures Without Cement Augmentation
- Clinical Outcomes of Single Intramedullary K-Wire Fixation with Figure-of-Eight Suture Augmentation for Ulnar Styloid Base and Distal Ulnar Metaphyseal Fractures
BibTeX
@article{nietosvaara2026need,
title = {{Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up.}},
author = {Nicolas Robert Nietosvaara and Jussi Kosola and Yrjänä Nietosvaara and Jani Puhakka and Ilkka Helenius and Topi Laaksonen},
journal = {Acta orthopaedica},
year = {2026},
month = nov,
doi = {10.2340/17453674.2026.47063},
url = {https://europepmc.org/article/MED/43062362},
note = {CC BY},
}
RIS
TY - JOUR
TI - Need for removal of flexible intramedullary nails used to treat femoral shaft fractures in children: an observational study of 55 children with a minimum of 5-year follow-up.
AU - Nicolas Robert Nietosvaara
AU - Jussi Kosola
AU - Yrjänä Nietosvaara
AU - Jani Puhakka
AU - Ilkka Helenius
AU - Topi Laaksonen
PY - 2026
DA - 2026/11/20
JO - Acta orthopaedica
DO - 10.2340/17453674.2026.47063
UR - https://europepmc.org/article/MED/43062362
AB - Background and purpose Removal of flexible intramedullary nails (FIN) in children with femoral shaft fractures has been considered unnecessary when nails are left unbent flush to the bone. We aimed to evaluate the frequency and timing of nail removal on demand.Methods This is an observational follow-up study including consecutive 3-14-year-old children with femoral shaft fractures treated during 2011-2018 with FIN. The instruction was to leave the distal ends of the nails unbent above the distal femoral physis. Alignment of the fracture and position of the nails were assessed after nailing and during follow-up. Data on nail removal rates and timing was collected with at least 5 years of follow-up. The outcomes for children with correctly placed nails were compared with those with nails that were too long, defined as cut at or below the distal femoral physis evaluated from postoperative radiographs.Results 55 consecutive children were included. All fractures healed in satisfactory alignment. FINs were too long in 24 patients (20 distally, 4 proximally). Hardware was removed in 37 (67%) children at a median of 2.4 years from surgery because of pain (range 0.3-9.3). Removal occurred in 21/24 of those with too long nails, and in 16/31 patients with correctly applied FIN, RR 1.7 (95% confidence interval 1.2-2.5, P = 0.005).Conclusion Half of the children with unbent FIN placed flush to the bone in femoral shaft fractures had removal of nails. Extending the nail to or below the distal femoral growth plate leads to hardware removal in nearly all cases, mainly due to pain.
SN - 1745-3674
SN - 1745-3682
ER -