Accurate calibration method of the Back-linked Fabry Perot interferometer using null channel for space-based gravitational wave antenna
Abstract
Accurate calibration of the detector response is essential for precision gravitational-wave (GW) observations. In the Back-linked Fabry-Perot Interferometer (BLFPI), which employs Fabry-Perot cavities to achieve high GW sensitivity, accurate calibration of the cavity response is particularly important because residual calibration errors directly limit the suppression of laser frequency noise. However, no practical calibration strategy for the cavity response has yet been established. In this paper, we propose a method for calibrating the cavity response using a null channel constructed from the three interferometer outputs of the triangular laser-link configuration. In null channel, GW signals are canceled and residual laser frequency noise indicates errors in the cavity response estimates. Therefore we can estimate the cavity response by optimizing the response parameters to minimize the integrated power of the null channel. We derive the estimation bias introduced by technical noise analytically and evaluate the performance of the proposed method numerically. The results show that the residual laser frequency noise after calibration is more than an order of magnitude below the designed BLFPI sensitivity throughout the observation band. This demonstrates that the proposed null-channel calibration method achieves the accuracy required for effective subtraction of laser frequency noise.
Related
- Gravitational Waves from Population III Black Hole Mergers in Primordial Gas Disks: Constraining Astrophysical Scenarios with the Laser Interferometer Space Antenna and the Einstein Telescope
- Probing Quadratically Coupled Ultralight Dark Matter with the Laser Interferometer Space Antenna
- Tracing small-scale structure formation through cosmic time with strong gravitational lensing: A case for a next-generation sub-millimetre/millimetre interferometer
- Effects of Solar Wind Plasma Noise on Stochastic Gravitational Wave Background Searches with a Space Based Interferometer Network
- Constraining the gravitational-wave breathing mode with LVK antenna patterns and GWTC data
BibTeX
@misc{okuma2026accurate,
title = {{Accurate calibration method of the Back-linked Fabry Perot interferometer using null channel for space-based gravitational wave antenna}},
author = {Yusuke Okuma and Shoki Iwaguchi and Ryosuke Sugimoto and Yutaro Enomoto and Kiwamu Izumi},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.14788},
eprint = {2611.14788},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.14788},
note = {CC BY 4.0},
}
RIS
TY - UNPB
TI - Accurate calibration method of the Back-linked Fabry Perot interferometer using null channel for space-based gravitational wave antenna
AU - Yusuke Okuma
AU - Shoki Iwaguchi
AU - Ryosuke Sugimoto
AU - Yutaro Enomoto
AU - Kiwamu Izumi
PY - 2026
DA - 2026/11/10
PB - arXiv
DO - 10.48550/arxiv.2611.14788
UR - https://arxiv.org/abs/2611.14788
AB - Accurate calibration of the detector response is essential for precision gravitational-wave (GW) observations. In the Back-linked Fabry-Perot Interferometer (BLFPI), which employs Fabry-Perot cavities to achieve high GW sensitivity, accurate calibration of the cavity response is particularly important because residual calibration errors directly limit the suppression of laser frequency noise. However, no practical calibration strategy for the cavity response has yet been established. In this paper, we propose a method for calibrating the cavity response using a null channel constructed from the three interferometer outputs of the triangular laser-link configuration. In null channel, GW signals are canceled and residual laser frequency noise indicates errors in the cavity response estimates. Therefore we can estimate the cavity response by optimizing the response parameters to minimize the integrated power of the null channel. We derive the estimation bias introduced by technical noise analytically and evaluate the performance of the proposed method numerically. The results show that the residual laser frequency noise after calibration is more than an order of magnitude below the designed BLFPI sensitivity throughout the observation band. This demonstrates that the proposed null-channel calibration method achieves the accuracy required for effective subtraction of laser frequency noise.
ER -