Circulating HMGB1 in Acute Respiratory Distress Syndrome: A Critical Review of Measurement Validity and Biosensor Evidence.

  1. 1Department of Medical Laboratories, College of Applied Medical Sciences, Shaqra University, Riyadh 11961, Saudi Arabia.

Abstract

Biological plausibility has outpaced the measurement and clinical validation of the role of circulating high-mobility group box 1 (HMGB1) in linking tissue injury to inflammation in acute respiratory distress syndrome (ARDS). This is a critical narrative review to determine whether the evidence concerning HMGB1 biology, circulating assays, and emerging biosensors can support the same clinical assertions. Focused appraisal of 33 clinical, biosensor, and analytical reports was facilitated by PubMed, Scopus, and Google Scholar searching and reference-list checking. Investigational trials reveal linkage to injury or poor outcomes, as well as negative results and significant selection criteria, sampling, assays, and endpoints. Reported prognostic thresholds are not applicable across matrices or platforms, and an enhanced panel AUC does not separate the contribution of HMGB1. There were six quantitative biosensor reports that showed detection of the analytes in controlled solutions, cell-derived material, or experimental disease states; however, human ARDS cohort validation was not reported in accessible biosensor reports. Thus, low detection limits cannot determine the accuracy or clinical utility of ARDS diagnosis. Central Gap is the information missing between an analytically created measurement and a prospectively validated clinical choice. There is need for matrix-specific assay verification, evaluation in an independent ARDS cohort, and, then, for testing to determine whether an HMGB1-informed strategy improves decision-making or outcomes.

Related

  1. Nasal intermittent positive pressure ventilation versus nasal continuous positive airway pressure as initial respiratory support during minimally invasive surfactant therapy in preterm infants with respiratory distress syndrome: a retrospective real-world cohort study
    Translational pediatricsPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  2. Respiratory Distress Syndrome: An Important Risk Factor for Intraventricular Hemorrhage in Preterm Neonates
    Melika Dzeko, Sabina Terzic, Sadzida Orucevic
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Global Protective Ventilator Settings Are Not Regional Protection: A Compartment-Resolved Framework for Personalizing Mechanical Ventilation in Acute Respiratory Distress Syndrome
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Efficacy of sivelestat sodium for patients with acute lung injury and acute respiratory distress syndrome: a systematic review and meta-analysis
    Xue-Ying Zhang, Xiao-Yan Ding, Han Chen
    Systematic ReviewsPeer-reviewedCC BY 4.0Clinical trials & evidence synthesisCrossref
  5. Downregulation of alcohol dehydrogenase family proteins suggests disrupted retinol metabolism in neonatal respiratory distress syndrome: an umbilical cord blood proteomics study
    Jing Wang, Ying Wei, Xuan Kan +1
    Frontiers in pediatricsPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{albargy2026circulating,
  title = {{Circulating HMGB1 in Acute Respiratory Distress Syndrome: A Critical Review of Measurement Validity and Biosensor Evidence.}},
  author = {Hassan Abdullah Albargy},
  journal = {Biosensors},
  year = {2026},
  month = oct,
  doi = {10.3390/bios16110618},
  url = {https://europepmc.org/article/MED/43082513},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Circulating HMGB1 in Acute Respiratory Distress Syndrome: A Critical Review of Measurement Validity and Biosensor Evidence.
AU  - Hassan Abdullah Albargy
PY  - 2026
DA  - 2026/10/30
JO  - Biosensors
DO  - 10.3390/bios16110618
UR  - https://europepmc.org/article/MED/43082513
AB  - Biological plausibility has outpaced the measurement and clinical validation of the role of circulating high-mobility group box 1 (HMGB1) in linking tissue injury to inflammation in acute respiratory distress syndrome (ARDS). This is a critical narrative review to determine whether the evidence concerning HMGB1 biology, circulating assays, and emerging biosensors can support the same clinical assertions. Focused appraisal of 33 clinical, biosensor, and analytical reports was facilitated by PubMed, Scopus, and Google Scholar searching and reference-list checking. Investigational trials reveal linkage to injury or poor outcomes, as well as negative results and significant selection criteria, sampling, assays, and endpoints. Reported prognostic thresholds are not applicable across matrices or platforms, and an enhanced panel AUC does not separate the contribution of HMGB1. There were six quantitative biosensor reports that showed detection of the analytes in controlled solutions, cell-derived material, or experimental disease states; however, human ARDS cohort validation was not reported in accessible biosensor reports. Thus, low detection limits cannot determine the accuracy or clinical utility of ARDS diagnosis. Central Gap is the information missing between an analytically created measurement and a prospectively validated clinical choice. There is need for matrix-specific assay verification, evaluation in an independent ARDS cohort, and, then, for testing to determine whether an HMGB1-informed strategy improves decision-making or outcomes.
SN  - 2079-6374
ER  -