Skip to content
DraconiticResearch
Search Sources API
194,230 studies31 sourcesUpdated 11 min ago
PreprintCC BY-NC-NDbioRxiv

Acoustic Masking of Electric Stimulation at Basal and Extra-Cochlear Sites

  1. 1Hannover Medical School

Abstract

Cochlear implant (CI) candidates with residual low frequency hearing increasingly receive hearing preserving electrode arrays to enable electric acoustic stimulation (EAS). However, assessing very low frequency hearing in newborns and young children remains difficult. Previous work has shown that acoustic stimulation can mask electrically evoked auditory percepts when stimulation sites are spatially separated. Whether such masking also occurs when electric stimulation is delivered near the round window (RW), prior to cochlear insertion, remains unclear. This study investigated ipsilateral acoustic masking of electric stimulation delivered at apical, basal, and near RW sites in 12 EAS users with residual low frequency hearing implanted with short or partially inserted electrode arrays. Using a psychophysical paradigm, threshold elevations of electric pulse trains were measured during simultaneous acoustic stimulation. Electric stimulation was applied at extra cochlear RW locations and intra cochlear basal and apical electrodes, while stimulation parameters were systematically varied. Electric stimulation near the RW reliably evoked auditory percepts without side effects, though optimal stimulation parameters and masking strength varied across participants. Strong acoustic masking was consistently observed for apical stimulation, whereas weaker but measurable masking occurred for basal and RW stimulation. A cochlear lumped parameter model indicated that approximately 5% of current delivered at the RW can reach apical regions, explaining the observed masking by low frequency acoustic tones. Masking strength correlated with residual hearing for apical stimulation only. These findings indicate that acoustic masking of apical electric stimulation, which correlated with residual hearing, holds potential as a diagnostic tool for assessing low frequency hearing post operatively. The detection of masking during both RW and basal stimulation represents a promising result, indicating that these stimulation paradigms can produce quantifiable effects. Given the considerable variability observed among participants, further investigation is required to establish the extent to which masking measures reflect residual hearing or hearing loss. Nonetheless, these results provide novel insight into auditory perception and side effects associated with basal and extra cochlear electric stimulation, informing future efforts to optimize this approach for low-frequency hearing assessment.

Related

  1. Deep brain stimulation changes basal ganglia output nuclei firing pattern in the dystonic hamster
    Arthur Leblois, René Reese, David Labarre +4
    Neurobiology of DiseasePeer-reviewedLicence not stated32 citedNeuroscienceHAL
  2. An in silico cortico-basal ganglia-thalamic testbed for comparing visual and deep brain stimulation in Parkinson’s disease
    Chun-Hui Huang, Wen-Shuo Chen, Jin-Rong Lai +4
    Frontiers in computational neurosciencePeer-reviewedCC BYFull textNeuroscienceEurope PMC
  3. Longitudinal Analysis of Cochlear Implant Stimulation Levels in the First Year: Optimizing Adult Fitting
    Maryam Hussain, Hylke F. E. van der Toom, Mats Voogelaar +2
    Ear and HearingPeer-reviewedCC BY 4.0Full textNeurosciencePMC
  4. Weak electric fields of deep brain stimulation can entrain spiking in multi-compartment cortical neuron models
    M. Bosman, N. Doorn, H. G. E. Meijer +2
    bioRxivPreprintCC BY-NC-NDFull textNeurosciencebioRxiv
  5. Closed-Loop Acoustic Stimulation of Slow Oscillations Using a Wireless EEG Headband: A Polysomnography-Validated Feasibility Study.
    Stefan L Jongejan, Anna C van der Heijden, Lucia M Talamini
    Sensors (Basel, Switzerland)Peer-reviewedCC BYFull textNeuroscienceEurope PMC
BibTeX
@misc{hinz2026acoustic,
  title = {{Acoustic Masking of Electric Stimulation at Basal and Extra-Cochlear Sites}},
  author = {P. Hinz and W. Nogueira},
  howpublished = {bioRxiv},
  year = {2026},
  month = sep,
  doi = {10.64898/2026.09.16.752065},
  url = {https://www.biorxiv.org/content/10.64898/2026.09.16.752065v1},
  note = {CC BY-NC-ND},
}
RIS
TY  - UNPB
TI  - Acoustic Masking of Electric Stimulation at Basal and Extra-Cochlear Sites
AU  - P. Hinz
AU  - W. Nogueira
PY  - 2026
DA  - 2026/09/16
PB  - bioRxiv
DO  - 10.64898/2026.09.16.752065
UR  - https://www.biorxiv.org/content/10.64898/2026.09.16.752065v1
AB  - Cochlear implant (CI) candidates with residual low frequency hearing increasingly receive hearing preserving electrode arrays to enable electric acoustic stimulation (EAS). However, assessing very low frequency hearing in newborns and young children remains difficult. Previous work has shown that acoustic stimulation can mask electrically evoked auditory percepts when stimulation sites are spatially separated. Whether such masking also occurs when electric stimulation is delivered near the round window (RW), prior to cochlear insertion, remains unclear. This study investigated ipsilateral acoustic masking of electric stimulation delivered at apical, basal, and near RW sites in 12 EAS users with residual low frequency hearing implanted with short or partially inserted electrode arrays. Using a psychophysical paradigm, threshold elevations of electric pulse trains were measured during simultaneous acoustic stimulation. Electric stimulation was applied at extra cochlear RW locations and intra cochlear basal and apical electrodes, while stimulation parameters were systematically varied. Electric stimulation near the RW reliably evoked auditory percepts without side effects, though optimal stimulation parameters and masking strength varied across participants. Strong acoustic masking was consistently observed for apical stimulation, whereas weaker but measurable masking occurred for basal and RW stimulation. A cochlear lumped parameter model indicated that approximately 5% of current delivered at the RW can reach apical regions, explaining the observed masking by low frequency acoustic tones. Masking strength correlated with residual hearing for apical stimulation only. These findings indicate that acoustic masking of apical electric stimulation, which correlated with residual hearing, holds potential as a diagnostic tool for assessing low frequency hearing post operatively. The detection of masking during both RW and basal stimulation represents a promising result, indicating that these stimulation paradigms can produce quantifiable effects. Given the considerable variability observed among participants, further investigation is required to establish the extent to which masking measures reflect residual hearing or hearing loss. Nonetheless, these results provide novel insight into auditory perception and side effects associated with basal and extra cochlear electric stimulation, informing future efforts to optimize this approach for low-frequency hearing assessment.
ER  -