New Asymmetric Transition Zone Centration Strategy for Refractive Corrections: Geometrical Background

  1. 1Research and Development/SCHWIND eye-tech-solutions GmbH, Kleinostheim, Germany
  2. 2Eyereum, Seoul, Republic of South Korea
  3. 3University Eye Clinic Svjetlost, Zagreb, Croatia

Abstract

Purpose: The purpose of this study was to present a novel asymmetric transition zone (aTZ) centration strategy for keratorefractive lenticule extraction and assess its theoretical potential to compensate for fixation-related lateral and torsional misalignments.

Methods: Proposed method adapts correction profiles for lateral and torsional errors by decentering optical zone (OZ) relative to the laser system axis while generating an asymmetric, crescent-shaped transition zone (TZ). Workflow includes defining target pupil position and intended treatment center, capturing intraoperative pupil location, computing deviation, and adjusting OZ and TZ geometry. Modeling was used to evaluate profile geometry, tissue consumption, and higher-order aberration (HOA) behavior.

Results: Modeling demonstrated that aTZ profiles maintain a centered symmetric OZ while creating asymmetric peripheral TZs compensating for fixation errors. Central thickness equals symmetric TZs (sTZs), with slightly reduced tissue-consumption volumes. Under large fixation errors, aTZ enlarges treatment diameter with a wider TZ whereas OZ remains unchanged. Spherical component theoretically induces peripheral coma and the astigmatic component peripheral trefoil. Unlike uncompensated sTZ profiles, where fixation-related errors directly translate into OZ decentration, aTZ design preserves OZ centration within its compensation limits and redistributes HOA induction to peripheral TZ.

Conclusions: A theoretical framework for aTZ strategy is presented, addressing fixation-related centration errors in lenticule refractive surgery. This method provides geometric compensation for lateral and torsional docking errors, which is theoretically expected to preserve optical quality and minimize tissue consumption better than standard symmetric strategies.

Translational Relevance: This approach extends customized TZ concepts from excimer platforms to lenticule-based surgery and may improve centration robustness when fixation inaccuracies are unavoidable.

Related

  1. Microcystic epithelial keratopathy associated with mirvetuximab soravtansine therapy: Multimodal corneal imaging and refractive changes
    A. Barloy, T.H.C. Tran
    Journal Français d'OphtalmologiePeer-reviewedLicence not statedGeneral biologyGeneral medicineHAL
  2. Distribution and factors associated with refractive errors among young adults attending ophthalmic clinics in Iraq: a multicenter cross-sectional study
    Hassan A. Aljaberi, Saeed Rahmani, Ali Ayatollahi
    Frontiers in ophthalmologyPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Three-Year Functional Vision, Longitudinal Refractive Outcomes, and Patient-Reported Outcomes After Bilateral Implantation of the Extend Bessel-Optics Intraocular Lens: An Independent Real-World Ambispective Study
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Adjunctive pirenoxine is associated with transient tear biomarker changes without sustained ocular surface benefit after refractive surgery: a randomized clinical trial
    Phit Upaphong, Nattayaporn Apaijai, Napaporn Tananuvat +3
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEpidemiology & public healthCrossref
  5. Artificial Intelligence Applications in Laser-Assisted Refractive Surgery—A Comprehensive Review
    Paul Filip Curcă, Mioara Laura Macovei, Ovidiu Mușat +6
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{verma2026asymmetric,
  title = {{New Asymmetric Transition Zone Centration Strategy for Refractive Corrections: Geometrical Background}},
  author = {Shwetabh Verma and David Kang and Ivan Gabric and Samuel Arba Mosquera},
  journal = {Translational Vision Science \& Technology},
  year = {2026},
  month = oct,
  doi = {10.1167/tvst.15.10.44},
  url = {https://doi.org/10.1167/tvst.15.10.44},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - New Asymmetric Transition Zone Centration Strategy for Refractive Corrections: Geometrical Background
AU  - Shwetabh Verma
AU  - David Kang
AU  - Ivan Gabric
AU  - Samuel Arba Mosquera
PY  - 2026
DA  - 2026/10/27
JO  - Translational Vision Science & Technology
DO  - 10.1167/tvst.15.10.44
UR  - https://doi.org/10.1167/tvst.15.10.44
AB  - Purpose: The purpose of this study was to present a novel asymmetric transition zone (aTZ) centration strategy for keratorefractive lenticule extraction and assess its theoretical potential to compensate for fixation-related lateral and torsional misalignments.  Methods: Proposed method adapts correction profiles for lateral and torsional errors by decentering optical zone (OZ) relative to the laser system axis while generating an asymmetric, crescent-shaped transition zone (TZ). Workflow includes defining target pupil position and intended treatment center, capturing intraoperative pupil location, computing deviation, and adjusting OZ and TZ geometry. Modeling was used to evaluate profile geometry, tissue consumption, and higher-order aberration (HOA) behavior.  Results: Modeling demonstrated that aTZ profiles maintain a centered symmetric OZ while creating asymmetric peripheral TZs compensating for fixation errors. Central thickness equals symmetric TZs (sTZs), with slightly reduced tissue-consumption volumes. Under large fixation errors, aTZ enlarges treatment diameter with a wider TZ whereas OZ remains unchanged. Spherical component theoretically induces peripheral coma and the astigmatic component peripheral trefoil. Unlike uncompensated sTZ profiles, where fixation-related errors directly translate into OZ decentration, aTZ design preserves OZ centration within its compensation limits and redistributes HOA induction to peripheral TZ.  Conclusions: A theoretical framework for aTZ strategy is presented, addressing fixation-related centration errors in lenticule refractive surgery. This method provides geometric compensation for lateral and torsional docking errors, which is theoretically expected to preserve optical quality and minimize tissue consumption better than standard symmetric strategies.  Translational Relevance: This approach extends customized TZ concepts from excimer platforms to lenticule-based surgery and may improve centration robustness when fixation inaccuracies are unavoidable.
SN  - 2164-2591
ER  -