Skip to content
DraconiticResearch
Search Sources API
182,544 studies31 sourcesUpdated 10 min ago
Peer-reviewedCC BYVolcanica

Evaluating and optimizing Raman analytical protocols for CO2 fluids

  1. 1Earth and Planetary Sciences, University of California, Berkeley, CA 94270, USA.
  2. 2Department of Earth and Environmental Sciences, University of Ottawa, Ottawa, ON K1N 6N5, Canada.

Abstract

Raman spectroscopy is widely used to quantify CO2 density in geological fluids, yet acquisition parameters, spectral processing methodologies and densimeter calibrations vary between laboratories. The precision of Raman CO2 measurements, and the broader applicability of densimeters generated for a specific instrument, are still debated. This study describes a series of experiments to investigate the effect of different instrument and acquisition parameters on CO2 densities and their errors that can be performed on different Raman instruments, allowing users to determine analytical best practices. First, we discuss the effect of spectral non-linearity, demonstrating that shifts in the selected acquisition window and the choice of Ne lines used for drift correction can generate a diversity of densimeters on a single instrument. However, our repeat measurements of natural fluid inclusion (FI) standards over ~3 years yield a 1σ variation of <0.01 g cm−3, indicating that when consistent methodologies are applied to calibration data and unknowns, Raman analyses are highly reproducible over many years. We then investigate the effect of parameters such as acquisition time, laser power, and sample positioning on peak fitting errors, rebutting recent suggestions that Raman analyses are associated with large uncertainties in Fermi-diad splitting. We show that although high laser powers greatly improve signal:noise ratios (and thus reduce peak fitting errors), natural fluid inclusions hosted in olivine show changes in calculated density outside analytical error with increasing powers (density changing by ~0 to 0.09 g cm−3 per 10 mW of increased power). The amount of heating of the trapped fluid, and thus the change in density, varies drastically on a sample-by-sample basis, with larger amounts of heating in materials hosting the fluid with high absorption coefficients (melt inclusions, and low Fo olivines). We recommend that users assess the degree of laser heating experienced by their samples and select a laser power that limits density changes to a level that will not compromise the objectives of their study. We also offer practical strategies to optimize signal without raising laser power, noting that small changes in focus and x-y position can greatly increase signal intensity.

Related

  1. Evaluating Biochar Crediting Protocols for Durable Carbon Removal
    Shreya Mukhopadhyay, Xiaodong Gao, Julia Seay +4
    EarthArXivPreprintCC BY-NC-ND 4.0Full textHydrology & soilsEarthArXiv
  2. Enhancing pollutant removal from contaminated soils using yield stress fluids as selective blocking agents
    Antonio Rodríguez de Castro, Amine Ben Abdelwahed, Henri Bertin
    Journal of Contaminant HydrologyPeer-reviewedLicence not stated9 citedEnvironmental science & pollutionHAL
  3. Forward modeling of near-field optical processes in pure rotational Raman temperature lidar
    Siying Chen, Rui Hu, Yurong Jiang +4
    Optics ExpressPeer-reviewedPublisher termsClimate scienceCrossref
  4. Satellite–Ground Intercomparison between EarthCARE/ATLID and the China Aerosol Raman Lidar Network (CARLNET): Part I. Case Studies
    Yubin Wei, Zhenping Yin, Shuang Zhang +6
    EGUspherePreprintCC BY 4.0General earth scienceEGUsphere
  5. Biodiversity credits hold promise, yet credit-generating protocols require safeguards to realize potential
    Katherine Culbertson, Sarah Federman, Lucia Catherine Camp +1
    Environmental Research LettersPeer-reviewedCC BY 4.0Full textEnvironmental science & pollutionCrossref
BibTeX
@article{wieser2026evaluating,
  title = {{Evaluating and optimizing Raman analytical protocols for CO2 fluids}},
  author = {Penny E. Wieser and Charlotte L. DeVitre and Isabelle Susman},
  journal = {Volcanica},
  year = {2026},
  month = aug,
  doi = {10.30909/vol/xczw4115},
  url = {https://doi.org/10.30909/vol/xczw4115},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Evaluating and optimizing Raman analytical protocols for CO2 fluids
AU  - Penny E. Wieser
AU  - Charlotte L. DeVitre
AU  - Isabelle Susman
PY  - 2026
DA  - 2026/08/01
JO  - Volcanica
DO  - 10.30909/vol/xczw4115
UR  - https://doi.org/10.30909/vol/xczw4115
AB  - Raman spectroscopy is widely used to quantify CO2 density in geological fluids, yet acquisition parameters, spectral processing methodologies and densimeter calibrations vary between laboratories. The precision of Raman CO2 measurements, and the broader applicability of densimeters generated for a specific instrument, are still debated. This study describes a series of experiments to investigate the effect of different instrument and acquisition parameters on CO2 densities and their errors that can be performed on different Raman instruments, allowing users to determine analytical best practices. First, we discuss the effect of spectral non-linearity, demonstrating that shifts in the selected acquisition window and the choice of Ne lines used for drift correction can generate a diversity of densimeters on a single instrument. However, our repeat measurements of natural fluid inclusion (FI) standards over ~3 years yield a 1σ variation of <0.01 g cm−3, indicating that when consistent methodologies are applied to calibration data and unknowns, Raman analyses are highly reproducible over many years. We then investigate the effect of parameters such as acquisition time, laser power, and sample positioning on peak fitting errors, rebutting recent suggestions that Raman analyses are associated with large uncertainties in Fermi-diad splitting. We show that although high laser powers greatly improve signal:noise ratios (and thus reduce peak fitting errors), natural fluid inclusions hosted in olivine show changes in calculated density outside analytical error with increasing powers (density changing by ~0 to 0.09 g cm−3 per 10 mW of increased power). The amount of heating of the trapped fluid, and thus the change in density, varies drastically on a sample-by-sample basis, with larger amounts of heating in materials hosting the fluid with high absorption coefficients (melt inclusions, and low Fo olivines). We recommend that users assess the degree of laser heating experienced by their samples and select a laser power that limits density changes to a level that will not compromise the objectives of their study. We also offer practical strategies to optimize signal without raising laser power, noting that small changes in focus and x-y position can greatly increase signal intensity.
SN  - 2610-3540
ER  -