Skip to content
DraconiticResearch
Search Sources API
194,216 studies31 sourcesUpdated 11 min ago
Peer-reviewedCC BY-NC-ND 4.0Magnetic Resonance in Chemistry

Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance

4 affiliations
  1. 1Statistics, Los Alamos National Laboratory Los Alamos New Mexico USA
  2. 2Materials Physics & Applications ‐ Quantum, Los Alamos National Laboratory Los Alamos New Mexico USA
  3. 3Department of Statistics and Data Sciences, University of Texas at Austin Austin Texas USA
  4. 4Nondestructive Testing & Evaluation, Los Alamos National Laboratory Los Alamos New Mexico USA

Abstract

Relaxation time constants in magnetic resonance are sensitive probes of molecular structure and dynamics and are critical for achieving spatial contrast in imaging, but measuring relaxation times is generally far more time‐consuming than traditional 1D spectroscopic experiments. Furthermore, the accuracy of the measured constants depends on numerous experimental factors. Currently, there are several available methods for designing a relaxation measurement (e.g., linear or logarithmic time spacing), but it is often unclear which method is preferable, how to select the minimum and maximum time points, or how many increments should be used, with all choices affecting the experimental time and the accuracy. Here, we consider optimal experimental designs and show that they maximize information per measurement, leading to more precise estimates for a specified relaxation model while in favorable cases reducing the number of measurements, and potentially the experimental time, required to achieve comparable precision relative to conventional sampling designs. Theoretical results on optimal experimental designs are explored both via simulation studies (for both mono‐ and multiexponential models) and via experiments for monoexponential T1 measurements on nuclear magnetic resonance systems. We emphasize that the resulting designs are optimal for parameter estimation under an assumed model rather than for model discovery or relaxation‐time distribution recovery. We conclude with practical guidelines for improved experimental design for relaxation‐time measurements in magnetic resonance while clarifying the limitations of model‐based optimal design.

Related

  1. Dielectric Relaxation and Equilibrium Thermodynamic Descriptors in Propanol Isomers: Radio-Frequency Measurements and openCOSMO-RS Analysis
    Samir Azizov, Tarana Nurubeyli, Kamala Khalilova +9
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  2. UniFFBench: evaluating universal machine learning force fields against experimental measurements
    Sajid Mannan, Vaibhav Bihani, Carmelo Gonzales +5
    Nature Computational SciencePeer-reviewedLicence not statedFull text17 citedMaterials & polymersOpenAlex
  3. Lowering Coordination Symmetry as a Strategy for Tuning Slow Magnetic Relaxation in Quasi-Isotropic Mn(II) Systems.
    Jacek Sawka, Barbara Machura, Roman Boča +5
    Inorganic chemistryPeer-reviewedCC BYFull textMaterials & polymersEurope PMC
  4. Unlocking 17O Natural-Abundance Nuclear Magnetic Resonance Detection in Solids
    Pierre Florian, Alia Hassan, Sebastian Wegner +1
    Journal of the American Chemical SocietyPeer-reviewedPublisher termsFull textPhysical chemistryHAL
  5. Magnetic Resonance Properties of Thin Py Films Suitable for Excitation of Spin Waves
    Tetiana Kalmykova, Sergei Krylov, Pavol Neilinger +4
    Nanomaterials (Basel, Switzerland)Peer-reviewedCC BYFull textMaterials & polymersEurope PMC
BibTeX
@article{klein2026optimal,
  title = {{Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance}},
  author = {Natalie E. Klein and Adam R. Altenhof and Amber J. Day and Michelle A. Espy and Michael W. Malone},
  journal = {Magnetic Resonance in Chemistry},
  year = {2026},
  month = sep,
  doi = {10.1002/mrc.70140},
  url = {https://doi.org/10.1002/mrc.70140},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Optimal Experimental Design for Fast and Accurate Relaxation Time Measurements in Magnetic Resonance
AU  - Natalie E. Klein
AU  - Adam R. Altenhof
AU  - Amber J. Day
AU  - Michelle A. Espy
AU  - Michael W. Malone
PY  - 2026
DA  - 2026/09/10
JO  - Magnetic Resonance in Chemistry
DO  - 10.1002/mrc.70140
UR  - https://doi.org/10.1002/mrc.70140
AB  - Relaxation time constants in magnetic resonance are sensitive probes of molecular structure and dynamics and are critical for achieving spatial contrast in imaging, but measuring relaxation times is generally far more time‐consuming than traditional 1D spectroscopic experiments. Furthermore, the accuracy of the measured constants depends on numerous experimental factors. Currently, there are several available methods for designing a relaxation measurement (e.g., linear or logarithmic time spacing), but it is often unclear which method is preferable, how to select the minimum and maximum time points, or how many increments should be used, with all choices affecting the experimental time and the accuracy. Here, we consider optimal experimental designs and show that they maximize information per measurement, leading to more precise estimates for a specified relaxation model while in favorable cases reducing the number of measurements, and potentially the experimental time, required to achieve comparable precision relative to conventional sampling designs. Theoretical results on optimal experimental designs are explored both via simulation studies (for both mono‐ and multiexponential models) and via experiments for monoexponential T1 measurements on nuclear magnetic resonance systems. We emphasize that the resulting designs are optimal for parameter estimation under an assumed model rather than for model discovery or relaxation‐time distribution recovery. We conclude with practical guidelines for improved experimental design for relaxation‐time measurements in magnetic resonance while clarifying the limitations of model‐based optimal design.
SN  - 0749-1581
SN  - 1097-458X
ER  -