Explicit pixel-value correction of lateral response artifacts in radiochromic film dosimetry: Evaluation of single-, double-, and triple-channel methods

Abstract

Background:Flatbed scanners introduce a lateral response artifact (LRA) perpendicular to lamp motion. Because LRA varies with position, pixel value (PV), color channel, and film model, it may violate the channel-common perturbation assumption of multichannel dosimetry. Purpose:To characterize PV-domain LRA in EBT4 and EBT-XD films, compare Lewis and Full corrections, and evaluate their effects on single-, double-, and triple-channel dosimetry. Methods:Seven films were scanned at seven lateral positions using a cyclic-shift design. For each position and RGB channel, center-equivalent response was modeled as PVc = A + B * PV. Lewis correction used two films with linear interpolation of A and B; Full correction used all center-local pairs with PCHIP interpolation of PVc - PV. Performance was assessed by portrait-landscape profile consistency and dose accuracy. Results: LRA was affine in PV, asymmetric about scanner center, and dependent on film model and channel. Both corrections reduced profile differences. Mean absolute profile differences across MU levels ranged from 1.4%-5.3% for EBT4 and 2.4%-6.8% for EBT-XD. The methods performed similarly for EBT4, while Full correction reduced discrepancies for several EBT-XD double- and triple-channel methods. Residual blue-channel errors limited blue, red-blue, and triple-channel performance. At 500 MU and above, red showed the best dose agreement; at 100 MU, both corrections increased deviations for several single-channel estimates. Full correction produced smaller deviations than Lewis in several EBT-XD conditions. Conclusions:LRA should be corrected in the raw-PV domain before dose reconstruction. Full correction better preserved profile consistency and dose accuracy, particularly for EBT-XD. Because improved profile consistency did not always improve central-dose agreement, both should be evaluated separately in commissioning.

Related

  1. Blank Spectrum Correction as a Robust Solution to Artifacts in Quantitative X-ray Fluorescence Mapping.
    Andrew M Crawford, Julia Balough, Yu-Ying Chen +7
    Analytical chemistryPeer-reviewedCC BYFull textApplied physics & instrumentationEurope PMC
  2. Coherent Structured Illumination Microscopy with Enhanced Suppression of Coherent Defocus Artifacts
    Kevin Crampton, Alan Joly, Long Nguyen +3
    Optics ExpressPeer-reviewedLicence not statedOptics & photonicsCrossref
  3. Empirical Evidence that Dirac–Fock Relativistic and Quantum Corrections are Z-indexing Artifacts
    Abdennour Abbas
    ChemRxivPreprintCC BY-NC-NDFull textAtomic, molecular & optical physicsChemRxiv
  4. Reducing ringing artifacts in Wiener deconvolution using implicit physical priors
    Jakub Czuchnowski, Jerome Mertz
    arXivPreprintCC BY-NC-ND 4.0Full textOptics & photonicsarXiv
  5. A single radiation hard pixel detector for proton dosimetry, imaging, energy resolution and beam monitoring
    Nico Frederic Brosda, Stephane Higueret, Nicolas Arbor +7
    HALPreprintarXiv licenceFull textApplied physics & instrumentationBiological & medical physicsHALarXiv
BibTeX
@misc{guo2026explicit,
  title = {{Explicit pixel-value correction of lateral response artifacts in radiochromic film dosimetry: Evaluation of single-, double-, and triple-channel methods}},
  author = {Lixiang Guo and Ken Kang-Hsin Wang},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.27224},
  eprint = {2609.27224},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.27224},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - Explicit pixel-value correction of lateral response artifacts in radiochromic film dosimetry: Evaluation of single-, double-, and triple-channel methods
AU  - Lixiang Guo
AU  - Ken Kang-Hsin Wang
PY  - 2026
DA  - 2026/09/23
PB  - arXiv
DO  - 10.48550/arxiv.2609.27224
UR  - https://arxiv.org/abs/2609.27224
AB  - Background:Flatbed scanners introduce a lateral response artifact (LRA) perpendicular to lamp motion. Because LRA varies with position, pixel value (PV), color channel, and film model, it may violate the channel-common perturbation assumption of multichannel dosimetry. Purpose:To characterize PV-domain LRA in EBT4 and EBT-XD films, compare Lewis and Full corrections, and evaluate their effects on single-, double-, and triple-channel dosimetry. Methods:Seven films were scanned at seven lateral positions using a cyclic-shift design. For each position and RGB channel, center-equivalent response was modeled as PVc = A + B * PV. Lewis correction used two films with linear interpolation of A and B; Full correction used all center-local pairs with PCHIP interpolation of PVc - PV. Performance was assessed by portrait-landscape profile consistency and dose accuracy. Results: LRA was affine in PV, asymmetric about scanner center, and dependent on film model and channel. Both corrections reduced profile differences. Mean absolute profile differences across MU levels ranged from 1.4%-5.3% for EBT4 and 2.4%-6.8% for EBT-XD. The methods performed similarly for EBT4, while Full correction reduced discrepancies for several EBT-XD double- and triple-channel methods. Residual blue-channel errors limited blue, red-blue, and triple-channel performance. At 500 MU and above, red showed the best dose agreement; at 100 MU, both corrections increased deviations for several single-channel estimates. Full correction produced smaller deviations than Lewis in several EBT-XD conditions. Conclusions:LRA should be corrected in the raw-PV domain before dose reconstruction. Full correction better preserved profile consistency and dose accuracy, particularly for EBT-XD. Because improved profile consistency did not always improve central-dose agreement, both should be evaluated separately in commissioning.
ER  -