HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition
Abstract
Self-supervised learning for wearable sensing is usually confined to a single dataset or device family, leaving open whether representations transfer across heterogeneous sensor configurations and whether gains come from pretraining rather than architecture or richer sensor input. We present HeteroWear, a sensor-aware self-supervised framework pretrained on an eight-dataset wearable corpus (173 subjects, 358,261 windows) spanning inertial and physiological signals across body locations, devices, and sampling rates. HeteroWear separates within-sensor temporal modeling from cross-sensor relational modeling using sensor-context embeddings, temporal and cross-sensor Transformers, and latent cross-attention fusion. Training combines structured sensor dropout, cross-configuration consistency, and per-axis masked sensor modeling; missing sensors are omitted rather than reconstructed. Under leave-one-dataset-out pretraining and subject-disjoint evaluation on PAMAP2, WISDM, HHAR, HARTH, and UCI-HAR, HeteroWear improves mean macro-F1 from 0.688 to 0.724 over the identical architecture trained from scratch, with the largest gain on HHAR (0.823 versus 0.741), and achieves the highest macro-F1 on four of five benchmarks relative to single-accelerometer supervised baselines. Held-out-device evaluation yields a mean +0.066 macro-F1 improvement. Under 50% test-time channel removal, HeteroWear retains 73.8% of full-channel performance versus 64.1% for the same architecture trained from scratch without sensor dropout. Ablations show that structured sensor dropout primarily drives robustness, while cross-configuration consistency and sensor-context encoding contribute to transfer.
Related
- Sigmoid-based supervised contrastive learning with von mises–fisher similarity and memory banks for visual recognition
- UniHAR: A unified hierarchical transformer with multi-scale temporal modeling for wearable human activity recognition
- Semi-supervised learning on singular data sets
- Semi-Supervised Learning with Noisy Proxy Covariates: Generalization Bounds and Distribution Regression
- Corrections to ``The Method of Gaps: Exact Expressions for the Generalization Error of Supervised Learning Algorithms
BibTeX
@misc{mohammadpour2026heterowear,
title = {{HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition}},
author = {Yasaman Mohammadpour and Pouya Shaeri},
howpublished = {arXiv},
year = {2026},
month = nov,
doi = {10.48550/arxiv.2611.19027},
eprint = {2611.19027},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2611.19027},
}
RIS
TY - UNPB
TI - HeteroWear: Sensor-Aware Self-Supervised Learning for Heterogeneous Wearable Activity Recognition
AU - Yasaman Mohammadpour
AU - Pouya Shaeri
PY - 2026
DA - 2026/11/13
PB - arXiv
DO - 10.48550/arxiv.2611.19027
UR - https://arxiv.org/abs/2611.19027
AB - Self-supervised learning for wearable sensing is usually confined to a single dataset or device family, leaving open whether representations transfer across heterogeneous sensor configurations and whether gains come from pretraining rather than architecture or richer sensor input. We present HeteroWear, a sensor-aware self-supervised framework pretrained on an eight-dataset wearable corpus (173 subjects, 358,261 windows) spanning inertial and physiological signals across body locations, devices, and sampling rates. HeteroWear separates within-sensor temporal modeling from cross-sensor relational modeling using sensor-context embeddings, temporal and cross-sensor Transformers, and latent cross-attention fusion. Training combines structured sensor dropout, cross-configuration consistency, and per-axis masked sensor modeling; missing sensors are omitted rather than reconstructed. Under leave-one-dataset-out pretraining and subject-disjoint evaluation on PAMAP2, WISDM, HHAR, HARTH, and UCI-HAR, HeteroWear improves mean macro-F1 from 0.688 to 0.724 over the identical architecture trained from scratch, with the largest gain on HHAR (0.823 versus 0.741), and achieves the highest macro-F1 on four of five benchmarks relative to single-accelerometer supervised baselines. Held-out-device evaluation yields a mean +0.066 macro-F1 improvement. Under 50% test-time channel removal, HeteroWear retains 73.8% of full-channel performance versus 64.1% for the same architecture trained from scratch without sensor dropout. Ablations show that structured sensor dropout primarily drives robustness, while cross-configuration consistency and sensor-context encoding contribute to transfer.
ER -